{"title":"Demagnetization study of an interior permanent magnet synchronous machine considering transient peak 3 phase short circuit current","authors":"Lee Seong Taek","doi":"10.1109/ECCE.2017.8096800","DOIUrl":null,"url":null,"abstract":"A sudden short circuit fault could potentially be a serious problem of interior permanent magnet synchronous machine (IPMSM) when the entire or partial demagnetization has occurred inside the permanent magnet. This paper investigates the maximum current limit of an IPMSM considering a large transient current at a symmetrical 3 phase short circuit fault. Finite Element Analysis (FEA) is used for the computation of 3 phase short circuit peak current while varying operating conditions including; input current vector and rotating speed. This computed 3 phase short circuit current is converted into dq-frame and then applied to check the irreversible demagnetization possibility of the IPMSM. During this process, the worst current angle is also investigated for considering partial demagnetization of permanent magnet.","PeriodicalId":93284,"journal":{"name":"ECCE ... : proceedings of the ... European Conference on Cognitive Ergonomics. European Conference on Cognitive Ergonomics","volume":"1 1","pages":"4694-4698"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ECCE ... : proceedings of the ... European Conference on Cognitive Ergonomics. European Conference on Cognitive Ergonomics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCE.2017.8096800","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

A sudden short circuit fault could potentially be a serious problem of interior permanent magnet synchronous machine (IPMSM) when the entire or partial demagnetization has occurred inside the permanent magnet. This paper investigates the maximum current limit of an IPMSM considering a large transient current at a symmetrical 3 phase short circuit fault. Finite Element Analysis (FEA) is used for the computation of 3 phase short circuit peak current while varying operating conditions including; input current vector and rotating speed. This computed 3 phase short circuit current is converted into dq-frame and then applied to check the irreversible demagnetization possibility of the IPMSM. During this process, the worst current angle is also investigated for considering partial demagnetization of permanent magnet.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
考虑瞬态峰值三相短路电流的内置式永磁同步电机消磁研究
当永磁体内部发生全部或部分退磁时,突然短路故障可能会成为内部永磁同步电机的严重问题。本文研究了在对称三相短路故障时考虑大暂态电流的IPMSM的最大限流问题。有限元分析(FEA)用于计算不同工况下的三相短路峰值电流,包括:输入电流矢量和转速。将计算得到的三相短路电流转换成dq帧,用于检测永磁同步电机的不可逆退磁可能性。在此过程中,考虑永磁体的部分退磁,还研究了最坏电流角。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Time for a change: Reducing perceived waiting time by making it more active A Systematic Literature Review on UCD4D Studies The Cognitive Relevance of a Formal Pre-incision Time-out in Surgery. Musical Elements in Sonification Support Visual Perception Demagnetization study of an interior permanent magnet synchronous machine considering transient peak 3 phase short circuit current
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1