Rapid identification of nerve agents Sarin (GB) and Soman (GD) with the use of a field-portable GC/SAW vapor detector and liquid desorption front-end device

Dudley Williams, George Pappas
{"title":"Rapid identification of nerve agents Sarin (GB) and Soman (GD) with the use of a field-portable GC/SAW vapor detector and liquid desorption front-end device","authors":"Dudley Williams,&nbsp;George Pappas","doi":"10.1002/(SICI)1520-6521(1999)3:1<45::AID-FACT6>3.0.CO;2-S","DOIUrl":null,"url":null,"abstract":"<p>The nerve agents Sarin (GB) and Soman (GD) were detected at the picogram level with the use of a field-portable gas chromatograph with a surface-acoustic-wave detector (SAW). The instrument, although primarily a vapor detector, can be modified with a simple front-end thermostat attachment, which allows for small-volume liquid injections for the detection of analytes in the vapor-pressure range of 0.1–5.0 torr. A field analytical method was developed with the use of the analyte surrogates dimethyl methyl phosphonate (DMMP) and triethyl phosphate (TEP). These compounds were used as internal standards by which agents GB and GD can be detected, with the use of this liquid injection method coupled to the vapor detector. Actual tests on GB and GD were performed under the same conditions, but in a more closely monitored but less field-representative laboratory environment. GB was quantitated from a calibration plot that relates signal to mass via a conversion factor in less than 10 s. The turnaround time for the instrument between data sets was 2 min, depending on the exact parameters of the method. ©1999 John Wiley &amp; Sons, Inc. Field Analyt Chem Technol 3:45–53, 1999</p>","PeriodicalId":100527,"journal":{"name":"Field Analytical Chemistry & Technology","volume":"3 1","pages":"45-53"},"PeriodicalIF":0.0000,"publicationDate":"1999-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1520-6521(1999)3:1<45::AID-FACT6>3.0.CO;2-S","citationCount":"35","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Field Analytical Chemistry & Technology","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291520-6521%281999%293%3A1%3C45%3A%3AAID-FACT6%3E3.0.CO%3B2-S","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 35

Abstract

The nerve agents Sarin (GB) and Soman (GD) were detected at the picogram level with the use of a field-portable gas chromatograph with a surface-acoustic-wave detector (SAW). The instrument, although primarily a vapor detector, can be modified with a simple front-end thermostat attachment, which allows for small-volume liquid injections for the detection of analytes in the vapor-pressure range of 0.1–5.0 torr. A field analytical method was developed with the use of the analyte surrogates dimethyl methyl phosphonate (DMMP) and triethyl phosphate (TEP). These compounds were used as internal standards by which agents GB and GD can be detected, with the use of this liquid injection method coupled to the vapor detector. Actual tests on GB and GD were performed under the same conditions, but in a more closely monitored but less field-representative laboratory environment. GB was quantitated from a calibration plot that relates signal to mass via a conversion factor in less than 10 s. The turnaround time for the instrument between data sets was 2 min, depending on the exact parameters of the method. ©1999 John Wiley & Sons, Inc. Field Analyt Chem Technol 3:45–53, 1999

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用野外便携式气相色谱/SAW蒸汽检测器和液体解吸前端装置快速鉴定神经毒剂沙林(GB)和索曼(GD)
采用带表面声波检测器(SAW)的野外便携式气相色谱仪对神经毒剂沙林(GB)和索曼(GD)进行了picogram水平的检测。该仪器虽然主要是一个蒸汽检测器,但可以通过简单的前端恒温器附件进行修改,从而允许在0.1-5.0 torr的蒸汽压力范围内进行小体积液体注射以检测分析物。采用代分析物二甲基膦酸甲酯(DMMP)和磷酸三乙酯(TEP)建立了现场分析方法。将这些化合物作为检测GB和GD的内标,采用液相进样法与气相检测器相结合。GB和GD的实际测试是在相同的条件下进行的,但在监测更密切但实地代表性较差的实验室环境中进行。GB从校准图中定量,该校准图通过小于10秒的转换因子将信号与质量联系起来。仪器在数据集之间的周转时间为2分钟,具体取决于方法的确切参数。©1999 John Wiley &儿子,Inc。野外分析化学技术(3):45 - 53,1999
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Technological innovation in field analytical chemistry A compact optical system for multi-determination of biochemical oxygen demand using disposable strips On-site gas chromatographic determination of explosives in soils Real-time classification performance and failure mode analysis of a physical/chemical sensor array and a probabilistic neural network Minicolumn field sampling and flow-injection-atomic absorption spectrometric determination of lead in seawater
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1