Double-layered dual-tuned RF coil using frequency-selectable PIN-diode control at 7-T MRI

IF 0.9 4区 医学 Q4 CHEMISTRY, PHYSICAL Concepts in Magnetic Resonance Part B-Magnetic Resonance Engineering Pub Date : 2018-05-21 DOI:10.1002/cmr.b.21363
Sang-Doc Han, Phil Heo, Han-Joong Kim, Hyunwoo Song, Donghyuk Kim, Jeung-Hoon Seo, Yeunchul Ryu, Young Noh, Kyoung-Nam Kim
{"title":"Double-layered dual-tuned RF coil using frequency-selectable PIN-diode control at 7-T MRI","authors":"Sang-Doc Han,&nbsp;Phil Heo,&nbsp;Han-Joong Kim,&nbsp;Hyunwoo Song,&nbsp;Donghyuk Kim,&nbsp;Jeung-Hoon Seo,&nbsp;Yeunchul Ryu,&nbsp;Young Noh,&nbsp;Kyoung-Nam Kim","doi":"10.1002/cmr.b.21363","DOIUrl":null,"url":null,"abstract":"<p>This article presents a dual-tuned (DT) radiofrequency (RF) coil for signal acquisition of 2 nuclei, namely, hydrogen (<sup>1</sup>H) and sodium (<sup>23</sup>Na), in the ultra-high magnetic field of a 7-T magnetic resonance imaging (MRI) system. The double-layered dual-tuned (DLDT) coil comprises a 2-loop coil configuration per single-pair geometry, with the <sup>1</sup>H and <sup>23</sup>Na coils being located on the outside and inside, respectively. The <sup>1</sup>H and <sup>23</sup>Na single-pair elements are tuned to resonance frequencies of 297.20 and 78.61 MHz, respectively. The single-pair geometry of the DLDT coil is extended to an 8-pair configuration to cover the human head, and the operation mode is transmission/reception (Tx/Rx). The 8-pair DLDT Tx/Rx coil array is designed with a non-overlapped single pair between the <sup>1</sup>H coil elements for geometric decoupling, and capacitive decoupling is implemented to minimize the mutual inductance coupling. The 2 resonance frequencies are fed through a single RF port to a common matching board, and each frequency is selected using the voltages at both ends of a PIN diode. Through use of the PIN diode in the DLDT coil configuration, with a voltage drop at both ends, different resonance frequencies can be selected for each coil element in accordance with the diode ON/OFF state. The experiments conducted showed that the proposed DLDT coil is effective in acquiring signals of <sup>1</sup>H and <sup>23</sup>Na in the MRI system.</p>","PeriodicalId":50623,"journal":{"name":"Concepts in Magnetic Resonance Part B-Magnetic Resonance Engineering","volume":"47B 4","pages":""},"PeriodicalIF":0.9000,"publicationDate":"2018-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/cmr.b.21363","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Concepts in Magnetic Resonance Part B-Magnetic Resonance Engineering","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cmr.b.21363","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 13

Abstract

This article presents a dual-tuned (DT) radiofrequency (RF) coil for signal acquisition of 2 nuclei, namely, hydrogen (1H) and sodium (23Na), in the ultra-high magnetic field of a 7-T magnetic resonance imaging (MRI) system. The double-layered dual-tuned (DLDT) coil comprises a 2-loop coil configuration per single-pair geometry, with the 1H and 23Na coils being located on the outside and inside, respectively. The 1H and 23Na single-pair elements are tuned to resonance frequencies of 297.20 and 78.61 MHz, respectively. The single-pair geometry of the DLDT coil is extended to an 8-pair configuration to cover the human head, and the operation mode is transmission/reception (Tx/Rx). The 8-pair DLDT Tx/Rx coil array is designed with a non-overlapped single pair between the 1H coil elements for geometric decoupling, and capacitive decoupling is implemented to minimize the mutual inductance coupling. The 2 resonance frequencies are fed through a single RF port to a common matching board, and each frequency is selected using the voltages at both ends of a PIN diode. Through use of the PIN diode in the DLDT coil configuration, with a voltage drop at both ends, different resonance frequencies can be selected for each coil element in accordance with the diode ON/OFF state. The experiments conducted showed that the proposed DLDT coil is effective in acquiring signals of 1H and 23Na in the MRI system.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
采用频率可选pin二极管控制的7-T MRI双层双调谐射频线圈
本文介绍了一种双调谐(DT)射频(RF)线圈,用于在7-T磁共振成像(MRI)系统的超高磁场中对氢(1H)和钠(23Na)两个核进行信号采集。双层双调谐(DLDT)线圈包括每个单对几何形状的2环线圈配置,1H和23Na线圈分别位于外部和内部。1H和23Na单对元件分别调谐到297.20和78.61 MHz的共振频率。DLDT线圈的单对几何结构扩展为8对配置,以覆盖人的头部,工作模式为发射/接收(Tx/Rx)。8对DLDT Tx/Rx线圈阵列在1H线圈元件之间设计了不重叠的单对,用于几何去耦,并实现了电容去耦,以最小化互感耦合。两个共振频率通过一个射频端口馈送到一个共同的匹配板,每个频率是使用在PIN二极管两端的电压选择。通过在DLDT线圈配置中使用PIN二极管,两端有一个压降,可以根据二极管的ON/OFF状态为每个线圈元件选择不同的谐振频率。实验结果表明,所提出的DLDT线圈可以有效地获取MRI系统中的1H和23Na信号。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.60
自引率
0.00%
发文量
3
审稿时长
>12 weeks
期刊介绍: Concepts in Magnetic Resonance Part B brings together engineers and physicists involved in the design and development of hardware and software employed in magnetic resonance techniques. The journal welcomes contributions predominantly from the fields of magnetic resonance imaging (MRI), nuclear magnetic resonance (NMR), and electron paramagnetic resonance (EPR), but also encourages submissions relating to less common magnetic resonance imaging and analytical methods. Contributors come from both academia and industry, to report the latest advancements in the development of instrumentation and computer programming to underpin medical, non-medical, and analytical magnetic resonance techniques.
期刊最新文献
Impact of Patient Body Posture on RF-Induced Energy Absorption by Orthopedic Plates Odd-Leg Birdcages for Geometric Decoupling in Multinuclear Imaging and Spectroscopy A General Framework for Automated Accurate Calculation of b-Matrix (Auto-b) in Diffusion MRI Pulse Sequences Development of Electron Paramagnetic Resonance Magnet System for In Vivo Tooth Dosimetry Diagnosis of Alzheimer’s Disease with Extreme Learning Machine on Whole-Brain Functional Connectivity
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1