A hysteresis current control based shunt current compensation scheme for power quality improvement in high power radiology applications

Shridevi R. Angadi, R. Nanjundaswamy, N. Srinivas, R. S. Ananda Murthy
{"title":"A hysteresis current control based shunt current compensation scheme for power quality improvement in high power radiology applications","authors":"Shridevi R. Angadi, R. Nanjundaswamy, N. Srinivas, R. S. Ananda Murthy","doi":"10.1109/ICPACE.2015.7274916","DOIUrl":null,"url":null,"abstract":"In this paper, a shunt active power filter scheme is proposed for a three phase system feeding a non-linear load. The system represents the HV generator used in high power radiology equipment. Hysteresis current control is used, which controls the operation such that a sinusoidal current is drawn from the source. The proposed method also reduces the THD, thus improving the power quality. The compensating currents are injected in phase opposition at the point of common contact to cancel out the harmonic currents in ac lines. The Hysteresis current control is used because it is simple and easy to implement. The simulation is carried out using MATLAB-SIMULINK software, whose results are displayed.","PeriodicalId":6644,"journal":{"name":"2015 International Conference on Power and Advanced Control Engineering (ICPACE)","volume":"40 1","pages":"53-58"},"PeriodicalIF":0.0000,"publicationDate":"2015-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Power and Advanced Control Engineering (ICPACE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPACE.2015.7274916","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In this paper, a shunt active power filter scheme is proposed for a three phase system feeding a non-linear load. The system represents the HV generator used in high power radiology equipment. Hysteresis current control is used, which controls the operation such that a sinusoidal current is drawn from the source. The proposed method also reduces the THD, thus improving the power quality. The compensating currents are injected in phase opposition at the point of common contact to cancel out the harmonic currents in ac lines. The Hysteresis current control is used because it is simple and easy to implement. The simulation is carried out using MATLAB-SIMULINK software, whose results are displayed.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种基于磁滞电流控制的高功率放射应用中电能质量改善的分流电流补偿方案
针对非线性负载的三相系统,提出了一种并联型有源电力滤波方案。该系统代表了大功率放射设备中使用的高压发电机。使用迟滞电流控制,它控制操作,使正弦电流从源提取。该方法还降低了THD,从而提高了电能质量。补偿电流在共触点相反注入,以抵消交流线路中的谐波电流。由于迟滞电流控制简单,易于实现,所以采用迟滞电流控制。利用MATLAB-SIMULINK软件进行了仿真,并给出了仿真结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Asset management in smart grids using improved Dissolved Gas Analysis PLC based intelligent power factor correctors for industrial power systems-A case study A multiple environment dispatch problem solution using ant colony optimization for micro-grids Modeling, simulation and comparative study of new compound alloy based P-I-N solar cells - An efficient way of energy management Modeling and analysis of 6 pulse rectifier used in HVDC link
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1