Axial voltage and gradient distribution of metal oxide surge arresters

N. Alame, G. Melik
{"title":"Axial voltage and gradient distribution of metal oxide surge arresters","authors":"N. Alame, G. Melik","doi":"10.1109/ICPADM.1991.172280","DOIUrl":null,"url":null,"abstract":"An investigation of the external axial voltage and gradient distribution along the porcelain shells of metal oxide arresters was conducted. Various service conditions such as on ground or elevated installation, proximity to energized apparatus or large earthed objects, and their influence on the voltage and gradient distribution were studied. It was found that if an EHV arrester designed for on ground installation is erected on a tall slender pedestal, then the voltage gradient along its bottom section is greatly increased. If such an arrester is operating in a polluted environment the increase in voltage gradient in one location may cause external surface arcing and excessive voltage stresses on zinc-oxide blocks in that part of the arrester. Such a situation can be effectively improved by fitting a bottom grading ring, the shape of which can be determined through a modeling procedure. Both computer modeling and experimental techniques were used in the analysis and close agreement between the theoretical and experimental results was obtained. An innovative, fast, and simple method of measurement was developed and extensively tested on 500 kV surge arresters.<<ETX>>","PeriodicalId":6450,"journal":{"name":"[1991] Proceedings of the 3rd International Conference on Properties and Applications of Dielectric Materials","volume":"24 1","pages":"1149-1151 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1991-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"[1991] Proceedings of the 3rd International Conference on Properties and Applications of Dielectric Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPADM.1991.172280","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

An investigation of the external axial voltage and gradient distribution along the porcelain shells of metal oxide arresters was conducted. Various service conditions such as on ground or elevated installation, proximity to energized apparatus or large earthed objects, and their influence on the voltage and gradient distribution were studied. It was found that if an EHV arrester designed for on ground installation is erected on a tall slender pedestal, then the voltage gradient along its bottom section is greatly increased. If such an arrester is operating in a polluted environment the increase in voltage gradient in one location may cause external surface arcing and excessive voltage stresses on zinc-oxide blocks in that part of the arrester. Such a situation can be effectively improved by fitting a bottom grading ring, the shape of which can be determined through a modeling procedure. Both computer modeling and experimental techniques were used in the analysis and close agreement between the theoretical and experimental results was obtained. An innovative, fast, and simple method of measurement was developed and extensively tested on 500 kV surge arresters.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
金属氧化物避雷器的轴向电压和梯度分布
对金属氧化物避雷器瓷壳外轴向电压和梯度分布进行了研究。研究了地面或高架安装、靠近带电设备或大型接地物体等各种使用条件对电压和梯度分布的影响。研究发现,将地面安装的超高压避雷器安装在细长的高基座上,会大大增加其底部的电压梯度。如果这样的避雷器在污染的环境中工作,在一个位置电压梯度的增加可能导致外部表面电弧和在避雷器的那一部分氧化锌块上的过大电压应力。这种情况可以通过拟合底部分级环来有效改善,通过建模程序可以确定底部分级环的形状。采用计算机模拟和实验相结合的方法进行了分析,理论结果与实验结果吻合较好。开发了一种创新、快速、简单的测量方法,并在500千伏避雷器上进行了广泛的测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Fluorocarbon liquid dielectric at DC-stresses Seismically superior substation insulator concepts based on polymer concrete Application of a triband partial discharge detector to on-site measurement Comparative analysis of vacuum and SF/sub 6/ as high voltage insulations Influence of defects on insulating properties of XLPE cable
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1