RIE of solenoidal microcoil glass mould with integrated sample container for micro-MRI

M. Klein, T. Ono, M. Esashi, J. Korvink
{"title":"RIE of solenoidal microcoil glass mould with integrated sample container for micro-MRI","authors":"M. Klein, T. Ono, M. Esashi, J. Korvink","doi":"10.1109/MEMSYS.2007.4433106","DOIUrl":null,"url":null,"abstract":"We report the fabrication of a solenoidal microcoil mould structure based on reactive ion etching (RIE) of 100 mum thick borosilicate glass wafers. For magnetic resonance imaging (MRI), glass has superior properties compared to silicon, e.g. the lower dielectric constant and transparency. Double-side polished substrates are pre-etched in a two step process, and then anodically bonded together to achieve a hollow structure inside the coil to serve as a sample container. Two additional etch steps that are each performed on the top and bottom surfaces of the bonded wafers complete the solenoidal coil mould structure.","PeriodicalId":6388,"journal":{"name":"2007 IEEE 20th International Conference on Micro Electro Mechanical Systems (MEMS)","volume":"77 1","pages":"345-348"},"PeriodicalIF":0.0000,"publicationDate":"2007-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE 20th International Conference on Micro Electro Mechanical Systems (MEMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEMSYS.2007.4433106","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

We report the fabrication of a solenoidal microcoil mould structure based on reactive ion etching (RIE) of 100 mum thick borosilicate glass wafers. For magnetic resonance imaging (MRI), glass has superior properties compared to silicon, e.g. the lower dielectric constant and transparency. Double-side polished substrates are pre-etched in a two step process, and then anodically bonded together to achieve a hollow structure inside the coil to serve as a sample container. Two additional etch steps that are each performed on the top and bottom surfaces of the bonded wafers complete the solenoidal coil mould structure.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
微磁共振成像用集成样品容器的电磁微线圈玻璃模具的研制
我们报道了一种基于反应离子蚀刻(RIE)的100微米厚硼硅玻璃晶圆的电磁微线圈模具结构的制备。对于磁共振成像(MRI),玻璃比硅具有更优越的性能,例如更低的介电常数和透明度。双面抛光基板在两步工艺中预蚀刻,然后阳极粘合在一起,以实现线圈内部的空心结构,作为样品容器。两个额外的蚀刻步骤,分别在粘合晶圆的顶部和底部表面进行,完成了螺线管线圈模具结构。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Process compensated micromechanical resonators A novel scanning Thermal Microscopy System High aspect ratio nano-scale CFX structures fabricated by deep-rie Electrochromic voxel array for 3D display Pyrolyzed polymer mesh electrode integrated into fluidic channel for gate type sensor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1