V. Diky, L. S. Zhura, A. G. Kabo, V. Y. Markov, G. J. Kabo
{"title":"HIGH-TEMPERATURE HEAT CAPACITY OF C60 FULLERENE","authors":"V. Diky, L. S. Zhura, A. G. Kabo, V. Y. Markov, G. J. Kabo","doi":"10.1081/FST-100107155","DOIUrl":null,"url":null,"abstract":"Heat capacity of C60 fullerene was measured by the scanning calorimetry method in the range 285–640 K and by the adiabatic calorimetry method in the range 99–310 K. The results are in agreement with a prediction made on the basis of the statistical thermodynamics.","PeriodicalId":12470,"journal":{"name":"Fullerene Science and Technology","volume":"24 3","pages":"543 - 551"},"PeriodicalIF":0.0000,"publicationDate":"2001-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fullerene Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1081/FST-100107155","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16
Abstract
Heat capacity of C60 fullerene was measured by the scanning calorimetry method in the range 285–640 K and by the adiabatic calorimetry method in the range 99–310 K. The results are in agreement with a prediction made on the basis of the statistical thermodynamics.