Yun-Yong Lin , Lin Mao , Jin Li, Zhi-Min Zhu, Yan-Hua Luo, Xiao-Hua Zhou, Shao-Dong Qiu, Fei Chen
{"title":"Exploring the anatomical factors influencing testes elasticity via ultrasound shear wave elastography: Preliminary results","authors":"Yun-Yong Lin , Lin Mao , Jin Li, Zhi-Min Zhu, Yan-Hua Luo, Xiao-Hua Zhou, Shao-Dong Qiu, Fei Chen","doi":"10.1016/j.androl.2023.100367","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>The aim of this study is to evaluate the anatomical factors influencing elasticity values of normal testicular parenchyma using shear wave elastography (SWE).</p></div><div><h3>Methods</h3><p><span>This study examined 68 healthy male volunteers (117 testes<span> in which standard transverse axis ultrasonography views could be obtained) via conventional scrotal ultrasonography and SWE. Both the mean (</span></span><em>E</em><sub>Mean</sub>) and standard deviation (<em>E</em><sub>SD</sub>) elasticity values were acquired.</p></div><div><h3>Results</h3><p>In the standard transverse axis view of the rete testis at the mid-lateral edge of the testes, the <em>E</em><sub>Mean</sub> values in 2<!--> <!-->mm the testicular parenchyma from the rete testis and the testicular capsule at the same level as the rete testis were all significantly larger than in the central zone (<em>P</em> <!--><<!--> <!-->0.001, <em>P</em> <!--><<!--> <!-->0.001, respectively). The <em>E</em><sub>Mean</sub> value in the testicular parenchyma 2<!--> <!-->mm from the testicular capsule on the line formed approximately 45° below the horizontal line of the rete testis was significantly larger than in the rete testis approximately 45° above the horizontal line (<em>P</em> <!--><<!--> <!-->0.001). In two standard transverse axis views, the <em>E</em><sub>SD</sub> values in other regions were significantly larger than those in the central zones (all <em>P</em> <!--><<!--> <!-->0.001). Also, the <em>E</em><sub>Mean</sub> values in the transmediastinal arteries were larger than those of the surrounding normal testicular parenchyma (<em>P</em> <!--><<!--> <!-->0.001).</p></div><div><h3>Conclusion</h3><p>Based on SWE, factors including the testicular capsule, the density of testicular fibrous septa, the depth of the Q-Box™, and the transmediastinal artery may influence the testes elasticity measurement.</p></div>","PeriodicalId":49129,"journal":{"name":"Revista Internacional De Andrologia","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Internacional De Andrologia","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1698031X23000274","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ANDROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose
The aim of this study is to evaluate the anatomical factors influencing elasticity values of normal testicular parenchyma using shear wave elastography (SWE).
Methods
This study examined 68 healthy male volunteers (117 testes in which standard transverse axis ultrasonography views could be obtained) via conventional scrotal ultrasonography and SWE. Both the mean (EMean) and standard deviation (ESD) elasticity values were acquired.
Results
In the standard transverse axis view of the rete testis at the mid-lateral edge of the testes, the EMean values in 2 mm the testicular parenchyma from the rete testis and the testicular capsule at the same level as the rete testis were all significantly larger than in the central zone (P < 0.001, P < 0.001, respectively). The EMean value in the testicular parenchyma 2 mm from the testicular capsule on the line formed approximately 45° below the horizontal line of the rete testis was significantly larger than in the rete testis approximately 45° above the horizontal line (P < 0.001). In two standard transverse axis views, the ESD values in other regions were significantly larger than those in the central zones (all P < 0.001). Also, the EMean values in the transmediastinal arteries were larger than those of the surrounding normal testicular parenchyma (P < 0.001).
Conclusion
Based on SWE, factors including the testicular capsule, the density of testicular fibrous septa, the depth of the Q-Box™, and the transmediastinal artery may influence the testes elasticity measurement.
期刊介绍:
Revista Internacional de Andrología es la revista oficial de la Asociación Española de Andrología, Medicina Sexual y Reproductiva (ASESA), la Sociedade Portuguesa de Ardrologia, la Sociedad Argentina de Andrología (SAA), la Asociación Iberoamericana de Sociedades de Andrología (ANDRO), y la Federación Española de Sociedades de Sexología.
La revista publicada trimestralmente es revisada por pares y es líder en el la especialidad y en español y portugués. Recientemente también publica artículos en inglés.
El objetivo de la revista es principalmente la promoción del conocimiento y la educación médica continua, con un enfoque especial en el público español y latinoamericano, a través de la publicación de las contribuciones importantes de la investigación en el campo. Todos los miembros de las sociedades antes mencionadas reciben la revista y otros suscriptores individuales e institucionales de España, Portugal y América Latina.