CENTRAL CORNEAL THICKNESS AND INTRAOCULAR PRESSURE CHANGES POST- PHACOEMULSIFICATION SURGERY IN GLAUCOMA PATIENTS WITH CATARACT.

Q4 Medicine Ceska a Slovenska Oftalmologie Pub Date : 2023-01-01 DOI:10.31348/2023/12
N Hong-Kee, Ahmad-Marwan, M Julieana, Chong, Vivian-Gong, Liza-Sharmini, Y Azhany
{"title":"CENTRAL CORNEAL THICKNESS AND INTRAOCULAR PRESSURE CHANGES POST- PHACOEMULSIFICATION SURGERY IN GLAUCOMA PATIENTS WITH CATARACT.","authors":"N Hong-Kee,&nbsp;Ahmad-Marwan,&nbsp;M Julieana,&nbsp;Chong,&nbsp;Vivian-Gong,&nbsp;Liza-Sharmini,&nbsp;Y Azhany","doi":"10.31348/2023/12","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>To compare the changes of central corneal thickness (CCT) and intraocular pressure (IOP) post-phacoemulsification between cataract patients with and without pre-existing glaucoma.</p><p><strong>Materials and methods: </strong>A prospective cohort study of 86 patients with visually significant cataract: 43 with pre-existing glaucoma (GC group) and 43 without pre-existing glaucoma (CO group). CCT and IOP were evaluated at baseline (pre-phacoemulsification), as well as at 2 hours, 1 day, 1 week and 6 weeks post-phacoemulsification.</p><p><strong>Results: </strong>The GC group have significantly thinner CCT pre-operatively (p = 0.003). There was a steady increase of CCT with the highest peak at 1 day post-phacoemulsification, followed by a steady decline of CCT and back to baseline at 6 weeks post-phacoemulsification in both groups. The GC group demonstrated a significant difference in CCT at 2 hours (mean difference 60.2 μm, p = 0.003) and 1 day (mean difference 70.6 μm, p = 0.002) post-phacoemulsification, compared to the CO group. There was a sudden increase in IOP at 2 hours post-phacoemulsification measured by GAT and DCT in both groups. This was followed by a gradual reduction of IOP, with significant reduction at 6 weeks post-phacoemulsification in both groups. However, there was no significant difference in IOP between the two groups. IOP measured by GAT and DCT showed strong correlation (r &gt; 0.75, p &lt; 0.001) in both groups. There was no significant correlation between GAT-IOP and CCT changes; nor between DCT-IOP and CCT changes in both groups.</p><p><strong>Conclusions: </strong>CCT changes post-phacoemulsification in patients with pre-existing glaucoma were similar, in spite of having thinner CCT pre-operatively. IOP measurement was not affected by CCT changes in glaucoma patients post-phacoemulsification. IOP measurement using GAT is comparable with DCT post-phacoemulsification.</p>","PeriodicalId":39839,"journal":{"name":"Ceska a Slovenska Oftalmologie","volume":"79 2","pages":"70-78"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ceska a Slovenska Oftalmologie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31348/2023/12","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: To compare the changes of central corneal thickness (CCT) and intraocular pressure (IOP) post-phacoemulsification between cataract patients with and without pre-existing glaucoma.

Materials and methods: A prospective cohort study of 86 patients with visually significant cataract: 43 with pre-existing glaucoma (GC group) and 43 without pre-existing glaucoma (CO group). CCT and IOP were evaluated at baseline (pre-phacoemulsification), as well as at 2 hours, 1 day, 1 week and 6 weeks post-phacoemulsification.

Results: The GC group have significantly thinner CCT pre-operatively (p = 0.003). There was a steady increase of CCT with the highest peak at 1 day post-phacoemulsification, followed by a steady decline of CCT and back to baseline at 6 weeks post-phacoemulsification in both groups. The GC group demonstrated a significant difference in CCT at 2 hours (mean difference 60.2 μm, p = 0.003) and 1 day (mean difference 70.6 μm, p = 0.002) post-phacoemulsification, compared to the CO group. There was a sudden increase in IOP at 2 hours post-phacoemulsification measured by GAT and DCT in both groups. This was followed by a gradual reduction of IOP, with significant reduction at 6 weeks post-phacoemulsification in both groups. However, there was no significant difference in IOP between the two groups. IOP measured by GAT and DCT showed strong correlation (r > 0.75, p < 0.001) in both groups. There was no significant correlation between GAT-IOP and CCT changes; nor between DCT-IOP and CCT changes in both groups.

Conclusions: CCT changes post-phacoemulsification in patients with pre-existing glaucoma were similar, in spite of having thinner CCT pre-operatively. IOP measurement was not affected by CCT changes in glaucoma patients post-phacoemulsification. IOP measurement using GAT is comparable with DCT post-phacoemulsification.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
青光眼合并白内障超声乳化手术后角膜中央厚度和眼压的变化。
目的:比较合并和不合并青光眼的白内障患者超声乳化术后角膜中央厚度(CCT)和眼压(IOP)的变化。材料与方法:对86例视力显著性白内障患者进行前瞻性队列研究,其中43例存在青光眼(GC组),43例未存在青光眼(CO组)。在基线(超声乳化术前)以及超声乳化术后2小时、1天、1周和6周评估CCT和IOP。结果:GC组术前CCT明显变薄(p = 0.003)。两组患者的CCT均稳定升高,在超声乳化术后1天达到峰值,随后稳定下降,并在超声乳化术后6周恢复到基线水平。与CO组相比,GC组在超声乳化术后2小时(平均差值60.2 μm, p = 0.003)和1天(平均差值70.6 μm, p = 0.002) CCT有显著差异。两组超声乳化术后2小时GAT和DCT测量IOP均突然升高。随后IOP逐渐降低,两组在超声乳化术后6周均显著降低。然而,两组间IOP无显著差异。GAT和DCT测量的IOP有很强的相关性(r >0.75, p <0.001)。GAT-IOP与CCT变化无显著相关;两组DCT-IOP和CCT的差异也不明显。结论:既往青光眼患者超声乳化术后的CCT变化相似,尽管术前CCT较薄。超声乳化术后青光眼患者的IOP测量不受CCT变化的影响。使用GAT测量IOP与超声乳化术后的DCT相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Ceska a Slovenska Oftalmologie
Ceska a Slovenska Oftalmologie Medicine-Ophthalmology
CiteScore
0.80
自引率
0.00%
发文量
0
期刊介绍: - Redakce přijímá pouze práce vyhovující po odborné stránce, které jsou na odpovídající profesionální a formální úrovni. - Uveřejněná práce se stává majetkem časopisu, přetisknout její část nebo obrázek lze jen s citací původu. - Rukopis zasílejte v originále a dobře čitelné kopii (je nutná také kopie tabulek, legend, podle možnosti i obrázků). - Listy číslujte v pravém horním rohu a spojujte svorkou, nesešívejte. Přijímáme práce psané na jedné straně kvalitního bílého nelesklého papíru formátu A4 (neprůklepový) na psacím stroji nebo počítači s obvyklými typy.
期刊最新文献
ULTRASOUND EXAMINATION OF THE ORBIT IN PATIENTS WITH THYROIDASSOCIATED ORBITOPATHY - EXAMINATION GUIDE AND RECOMMENDATIONS FOR EVERYDAY PRACTICE. A REVIEW. Diagnostic Importance of OCT Pachymetry in Keratoconus. Improvement of Visual Field Defects after Neuroembolization Treatment of Intracranial Aneurysms. Case Reports. Pars Plana Vitrectomy in the Treatment of Rhegmatogenous Retinal Detachment. Refractive Errors Among Members of the Armed Forces of the Czech Republic.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1