Paul Billoir, Virginie Barbay, Marielle Fresel, Sabine Brunel, Véronique Le Cam Duchez
{"title":"[Evaluation of a diagnostic test for heparin-induced thrombocytopenia: validation of a delayed test time].","authors":"Paul Billoir, Virginie Barbay, Marielle Fresel, Sabine Brunel, Véronique Le Cam Duchez","doi":"10.1684/abc.2023.1810","DOIUrl":null,"url":null,"abstract":"<p><p>Heparin-induced thrombocytopenia (HIT) is a rare, iatrogenic condition, characterized by its potential severity and diagnostic difficulties. The diagnosis is based on a set of arguments allowing the calculation of a pre-test score pointing to HIT. There are rapid diagnostic tests for suspected HIT. Among these, the STic Expert® HIT has a good sensitivity to detect HIT. However, it must be performed within 2 hours after sampling. The aim of this study was to evaluate a delayed STic Expert® HIT test at 8 hours and in frozen plasma. Thirty-six patients were prospectively included for HIT testing between April 01, 2018, and July 1, 2022, at the University Rouen Hospital. For any request for HIT testing, an analysis by STic Expert® HIT was performed within 2 hours and 8 hours post-sampling. Any positive result was confirmed by a functional test, platelet aggregation with heparin, release of 14C-serotonin assay (SRA), and immunological assay by a research for anti-platelet factor 4 IgG antibodies. Twenty-three patients had a STic Expert® HIT. Sixteen presented platelet aggregations in the presence of heparin and had a positive anti-PF4 test, 17 had a positive SRA. Six patients had no HIT. For the test performed within 2 hours of collection, the Se = 100%, Sp = 68.42%, PPV = 73.91%, and NPV = 100%. The X2 = 18.21 with p < 0.001. For the test performed at 8 hours post sampling, the Se = 100%, Sp = 68.42%, PPV = 73.91% and NPV = 100%. The X2 = 18.21 with p < 0.001. In conclusion, we have demonstrated that the STic Expert® can be used to perform an HIT diagnostic test 8 hours after sampling and on thawed plasma. However, this study needs to be confirmed on a larger number of samples.</p>","PeriodicalId":7892,"journal":{"name":"Annales de biologie clinique","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2023-07-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annales de biologie clinique","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1684/abc.2023.1810","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Heparin-induced thrombocytopenia (HIT) is a rare, iatrogenic condition, characterized by its potential severity and diagnostic difficulties. The diagnosis is based on a set of arguments allowing the calculation of a pre-test score pointing to HIT. There are rapid diagnostic tests for suspected HIT. Among these, the STic Expert® HIT has a good sensitivity to detect HIT. However, it must be performed within 2 hours after sampling. The aim of this study was to evaluate a delayed STic Expert® HIT test at 8 hours and in frozen plasma. Thirty-six patients were prospectively included for HIT testing between April 01, 2018, and July 1, 2022, at the University Rouen Hospital. For any request for HIT testing, an analysis by STic Expert® HIT was performed within 2 hours and 8 hours post-sampling. Any positive result was confirmed by a functional test, platelet aggregation with heparin, release of 14C-serotonin assay (SRA), and immunological assay by a research for anti-platelet factor 4 IgG antibodies. Twenty-three patients had a STic Expert® HIT. Sixteen presented platelet aggregations in the presence of heparin and had a positive anti-PF4 test, 17 had a positive SRA. Six patients had no HIT. For the test performed within 2 hours of collection, the Se = 100%, Sp = 68.42%, PPV = 73.91%, and NPV = 100%. The X2 = 18.21 with p < 0.001. For the test performed at 8 hours post sampling, the Se = 100%, Sp = 68.42%, PPV = 73.91% and NPV = 100%. The X2 = 18.21 with p < 0.001. In conclusion, we have demonstrated that the STic Expert® can be used to perform an HIT diagnostic test 8 hours after sampling and on thawed plasma. However, this study needs to be confirmed on a larger number of samples.
期刊介绍:
Multidisciplinary information with direct relevance to everyday practice
Annales de Biologie Clinique, the official journal of the French Society of Clinical Biology (SFBC), supports biologists in areas including continuing education, laboratory accreditation and technique validation.
With original articles, abstracts and accounts of everyday practice, the journal provides details of advances in knowledge, techniques and equipment, as well as a forum for discussion open to the entire community.