{"title":"脊髓刺激器植入脉冲发生器在择期手术后失活:一个认识不足的问题。","authors":"Jordan N Norris, Nathan Esplin, Rosh Bharthi, Michael Patterson, Nestor D Tomycz","doi":"10.1038/s41394-023-00591-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Study design: </strong>We retrospectively analyzed a database of implanted pulse generators (IPGs) for spinal cord stimulation (SCS) implanted by a single surgeon (NDT). We additionally report a series of five illustrative patient cases.</p><p><strong>Objectives: </strong>The electronics of SCS IPGs are susceptible to damage when implanted patients undergo surgery. Some SCSs have a dedicated surgery mode, while others recommend turning the SCS off to protect it from damage. IPG inactivation may require resetting or replacement surgery. We aimed to explore the prevalence of this real-world problem which has not been studied.</p><p><strong>Setting: </strong>Pittsburgh, Pennsylvania.</p><p><strong>Methods: </strong>Using a single surgeon SCS database, we identified cases of IPG inactivation after a non-SCS surgery and analyzed the management. We then reviewed the charts of five illustrative cases.</p><p><strong>Results: </strong>Among 490 SCS IPG implantations between 2016-2022, 15 (3%) of the 490 patients' IPGs became inactivated after another non-SCS surgery. 12 (80%) required surgical IPG replacement, while 3 (20%) were able to have their IPG function restored non-operatively. In cases analyzed thus far, surgery mode was often not activated prior to surgery.</p><p><strong>Conclusion: </strong>SCS IPG inactivation by surgery is not a rare problem and is presumably engendered by monopolar electrocautery. Premature IPG replacement surgery carries risks and reduces the cost-effectiveness of SCS. Awareness of this problem may prompt more preventative measures to be taken by surgeons, patients, and caretakers, and encourage technological advances to render IPGs less vulnerable to surgical tools. Further research is needed to determine what quality improvement measures could prevent electrical damage to IPGs.</p>","PeriodicalId":22079,"journal":{"name":"Spinal Cord Series and Cases","volume":"9 1","pages":"29"},"PeriodicalIF":0.7000,"publicationDate":"2023-07-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10336009/pdf/","citationCount":"0","resultStr":"{\"title\":\"Inactivation of spinal cord stimulator implanted pulse generators after elective surgery: an under-recognized problem.\",\"authors\":\"Jordan N Norris, Nathan Esplin, Rosh Bharthi, Michael Patterson, Nestor D Tomycz\",\"doi\":\"10.1038/s41394-023-00591-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Study design: </strong>We retrospectively analyzed a database of implanted pulse generators (IPGs) for spinal cord stimulation (SCS) implanted by a single surgeon (NDT). We additionally report a series of five illustrative patient cases.</p><p><strong>Objectives: </strong>The electronics of SCS IPGs are susceptible to damage when implanted patients undergo surgery. Some SCSs have a dedicated surgery mode, while others recommend turning the SCS off to protect it from damage. IPG inactivation may require resetting or replacement surgery. We aimed to explore the prevalence of this real-world problem which has not been studied.</p><p><strong>Setting: </strong>Pittsburgh, Pennsylvania.</p><p><strong>Methods: </strong>Using a single surgeon SCS database, we identified cases of IPG inactivation after a non-SCS surgery and analyzed the management. We then reviewed the charts of five illustrative cases.</p><p><strong>Results: </strong>Among 490 SCS IPG implantations between 2016-2022, 15 (3%) of the 490 patients' IPGs became inactivated after another non-SCS surgery. 12 (80%) required surgical IPG replacement, while 3 (20%) were able to have their IPG function restored non-operatively. In cases analyzed thus far, surgery mode was often not activated prior to surgery.</p><p><strong>Conclusion: </strong>SCS IPG inactivation by surgery is not a rare problem and is presumably engendered by monopolar electrocautery. Premature IPG replacement surgery carries risks and reduces the cost-effectiveness of SCS. Awareness of this problem may prompt more preventative measures to be taken by surgeons, patients, and caretakers, and encourage technological advances to render IPGs less vulnerable to surgical tools. Further research is needed to determine what quality improvement measures could prevent electrical damage to IPGs.</p>\",\"PeriodicalId\":22079,\"journal\":{\"name\":\"Spinal Cord Series and Cases\",\"volume\":\"9 1\",\"pages\":\"29\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2023-07-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10336009/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Spinal Cord Series and Cases\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1038/s41394-023-00591-5\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spinal Cord Series and Cases","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1038/s41394-023-00591-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

研究设计:我们回顾性分析了由一名外科医生(NDT)植入的用于脊髓刺激(SCS)的植入式脉冲发生器(IPG)数据库。此外,我们还报告了五例典型患者的系列病例:SCS IPG 的电子元件在植入患者接受手术时很容易损坏。有些 SCS 有专门的手术模式,有些则建议关闭 SCS 以防止其受损。IPG 失活可能需要重置或更换手术。我们的目的是探索这一尚未研究过的现实问题的普遍性:地点:宾夕法尼亚州匹兹堡:利用单个外科医生 SCS 数据库,我们确定了非 SCS 手术后 IPG 失活的病例,并分析了处理方法。然后,我们查看了五个典型病例的病历:结果:在 2016-2022 年间植入的 490 例 SCS IPG 中,有 15 例(3%)患者的 IPG 在另一次非 SCS 手术后失活。12例(80%)需要手术更换IPG,3例(20%)通过非手术恢复了IPG功能。在迄今为止分析的病例中,手术模式通常在手术前未被激活:结论:手术导致 SCS IPG 失活并非罕见问题,可能是由单极电烧引起的。过早进行 IPG 更换手术会带来风险,并降低 SCS 的成本效益。对这一问题的认识可能会促使外科医生、患者和护理人员采取更多预防措施,并鼓励技术进步,使 IPG 不易受手术工具的影响。要确定哪些质量改进措施可以防止 IPG 受到电损伤,还需要进一步的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Inactivation of spinal cord stimulator implanted pulse generators after elective surgery: an under-recognized problem.

Study design: We retrospectively analyzed a database of implanted pulse generators (IPGs) for spinal cord stimulation (SCS) implanted by a single surgeon (NDT). We additionally report a series of five illustrative patient cases.

Objectives: The electronics of SCS IPGs are susceptible to damage when implanted patients undergo surgery. Some SCSs have a dedicated surgery mode, while others recommend turning the SCS off to protect it from damage. IPG inactivation may require resetting or replacement surgery. We aimed to explore the prevalence of this real-world problem which has not been studied.

Setting: Pittsburgh, Pennsylvania.

Methods: Using a single surgeon SCS database, we identified cases of IPG inactivation after a non-SCS surgery and analyzed the management. We then reviewed the charts of five illustrative cases.

Results: Among 490 SCS IPG implantations between 2016-2022, 15 (3%) of the 490 patients' IPGs became inactivated after another non-SCS surgery. 12 (80%) required surgical IPG replacement, while 3 (20%) were able to have their IPG function restored non-operatively. In cases analyzed thus far, surgery mode was often not activated prior to surgery.

Conclusion: SCS IPG inactivation by surgery is not a rare problem and is presumably engendered by monopolar electrocautery. Premature IPG replacement surgery carries risks and reduces the cost-effectiveness of SCS. Awareness of this problem may prompt more preventative measures to be taken by surgeons, patients, and caretakers, and encourage technological advances to render IPGs less vulnerable to surgical tools. Further research is needed to determine what quality improvement measures could prevent electrical damage to IPGs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Spinal Cord Series and Cases
Spinal Cord Series and Cases Medicine-Neurology (clinical)
CiteScore
2.20
自引率
8.30%
发文量
92
期刊最新文献
Validation of the Nepali version of the Spinal Cord Independence Measure Self-Report. Clinical features and rehabilitation outcome after surgical treatment of spinal meningioma. Surgically managed traumatic spinal cord injury in Singapore: a descriptive study across two level one trauma centres. Non-surgical spinal cord infarction: case series & long-term follow-up of functional outcome. The frequency of osteomyelitis after pressure injury in spinal cord injury: a systematic review and meta-analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1