Kelsey L Bower, Angela M Noecker, Martin M Reich, Cameron C McIntyre
{"title":"量化与脑深部刺激电极术后定位相关的变异性。","authors":"Kelsey L Bower, Angela M Noecker, Martin M Reich, Cameron C McIntyre","doi":"10.1159/000530462","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Computational models of deep brain stimulation (DBS) have become common tools in clinical research studies that attempt to establish correlations between stimulation locations in the brain and behavioral outcome measures. However, the accuracy of any patient-specific DBS model depends heavily upon accurate localization of the DBS electrodes within the anatomy, which is typically defined via co-registration of clinical CT and MRI datasets. Several different approaches exist for this challenging registration problem, and each approach will result in a slightly different electrode localization. The goal of this study was to better understand how different processing steps (e.g., cost-function masking, brain extraction, intensity remapping) affect the estimate of the DBS electrode location in the brain.</p><p><strong>Methods: </strong>No \"gold standard\" exists for this kind of analysis, as the exact location of the electrode in the living human brain cannot be determined with existing clinical imaging approaches. However, we can estimate the uncertainty associated with the electrode position, which can be used to guide statistical analyses in DBS mapping studies. Therefore, we used high-quality clinical datasets from 10 subthalamic DBS subjects and co-registered their long-term postoperative CT with their preoperative surgical targeting MRI using 9 different approaches. The distances separating all of the electrode location estimates were calculated for each subject.</p><p><strong>Results: </strong>On average, electrodes were located within a median distance of 0.57 mm (0.49-0.74) of one another across the different registration approaches. However, when considering electrode location estimates from short-term postoperative CTs, the median distance increased to 2.01 mm (1.55-2.78).</p><p><strong>Conclusions: </strong>The results of this study suggest that electrode location uncertainty needs to be factored into statistical analyses that attempt to define correlations between stimulation locations and clinical outcomes.</p>","PeriodicalId":22078,"journal":{"name":"Stereotactic and Functional Neurosurgery","volume":"101 4","pages":"277-284"},"PeriodicalIF":1.9000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10833063/pdf/","citationCount":"0","resultStr":"{\"title\":\"Quantifying the Variability Associated with Postoperative Localization of Deep Brain Stimulation Electrodes.\",\"authors\":\"Kelsey L Bower, Angela M Noecker, Martin M Reich, Cameron C McIntyre\",\"doi\":\"10.1159/000530462\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Computational models of deep brain stimulation (DBS) have become common tools in clinical research studies that attempt to establish correlations between stimulation locations in the brain and behavioral outcome measures. However, the accuracy of any patient-specific DBS model depends heavily upon accurate localization of the DBS electrodes within the anatomy, which is typically defined via co-registration of clinical CT and MRI datasets. Several different approaches exist for this challenging registration problem, and each approach will result in a slightly different electrode localization. The goal of this study was to better understand how different processing steps (e.g., cost-function masking, brain extraction, intensity remapping) affect the estimate of the DBS electrode location in the brain.</p><p><strong>Methods: </strong>No \\\"gold standard\\\" exists for this kind of analysis, as the exact location of the electrode in the living human brain cannot be determined with existing clinical imaging approaches. However, we can estimate the uncertainty associated with the electrode position, which can be used to guide statistical analyses in DBS mapping studies. Therefore, we used high-quality clinical datasets from 10 subthalamic DBS subjects and co-registered their long-term postoperative CT with their preoperative surgical targeting MRI using 9 different approaches. The distances separating all of the electrode location estimates were calculated for each subject.</p><p><strong>Results: </strong>On average, electrodes were located within a median distance of 0.57 mm (0.49-0.74) of one another across the different registration approaches. However, when considering electrode location estimates from short-term postoperative CTs, the median distance increased to 2.01 mm (1.55-2.78).</p><p><strong>Conclusions: </strong>The results of this study suggest that electrode location uncertainty needs to be factored into statistical analyses that attempt to define correlations between stimulation locations and clinical outcomes.</p>\",\"PeriodicalId\":22078,\"journal\":{\"name\":\"Stereotactic and Functional Neurosurgery\",\"volume\":\"101 4\",\"pages\":\"277-284\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10833063/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Stereotactic and Functional Neurosurgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1159/000530462\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/6/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"NEUROIMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Stereotactic and Functional Neurosurgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000530462","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/6/28 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"NEUROIMAGING","Score":null,"Total":0}
Quantifying the Variability Associated with Postoperative Localization of Deep Brain Stimulation Electrodes.
Introduction: Computational models of deep brain stimulation (DBS) have become common tools in clinical research studies that attempt to establish correlations between stimulation locations in the brain and behavioral outcome measures. However, the accuracy of any patient-specific DBS model depends heavily upon accurate localization of the DBS electrodes within the anatomy, which is typically defined via co-registration of clinical CT and MRI datasets. Several different approaches exist for this challenging registration problem, and each approach will result in a slightly different electrode localization. The goal of this study was to better understand how different processing steps (e.g., cost-function masking, brain extraction, intensity remapping) affect the estimate of the DBS electrode location in the brain.
Methods: No "gold standard" exists for this kind of analysis, as the exact location of the electrode in the living human brain cannot be determined with existing clinical imaging approaches. However, we can estimate the uncertainty associated with the electrode position, which can be used to guide statistical analyses in DBS mapping studies. Therefore, we used high-quality clinical datasets from 10 subthalamic DBS subjects and co-registered their long-term postoperative CT with their preoperative surgical targeting MRI using 9 different approaches. The distances separating all of the electrode location estimates were calculated for each subject.
Results: On average, electrodes were located within a median distance of 0.57 mm (0.49-0.74) of one another across the different registration approaches. However, when considering electrode location estimates from short-term postoperative CTs, the median distance increased to 2.01 mm (1.55-2.78).
Conclusions: The results of this study suggest that electrode location uncertainty needs to be factored into statistical analyses that attempt to define correlations between stimulation locations and clinical outcomes.
期刊介绍:
''Stereotactic and Functional Neurosurgery'' provides a single source for the reader to keep abreast of developments in the most rapidly advancing subspecialty within neurosurgery. Technological advances in computer-assisted surgery, robotics, imaging and neurophysiology are being applied to clinical problems with ever-increasing rapidity in stereotaxis more than any other field, providing opportunities for new approaches to surgical and radiotherapeutic management of diseases of the brain, spinal cord, and spine. Issues feature advances in the use of deep-brain stimulation, imaging-guided techniques in stereotactic biopsy and craniotomy, stereotactic radiosurgery, and stereotactically implanted and guided radiotherapeutics and biologicals in the treatment of functional and movement disorders, brain tumors, and other diseases of the brain. Background information from basic science laboratories related to such clinical advances provides the reader with an overall perspective of this field. Proceedings and abstracts from many of the key international meetings furnish an overview of this specialty available nowhere else. ''Stereotactic and Functional Neurosurgery'' meets the information needs of both investigators and clinicians in this rapidly advancing field.