通过多因素降维实现医学超声扫描仪维护变量之间的相互作用。

IF 2.9 3区 医学 Q3 ENGINEERING, BIOMEDICAL Expert Review of Medical Devices Pub Date : 2023-07-01 Epub Date: 2023-08-07 DOI:10.1080/17434440.2023.2243208
Alejandro Prieto-Fernández, Gonzalo Sánchez-Barroso, Jaime González-Domínguez, Justo García-Sanz-Calcedo
{"title":"通过多因素降维实现医学超声扫描仪维护变量之间的相互作用。","authors":"Alejandro Prieto-Fernández,&nbsp;Gonzalo Sánchez-Barroso,&nbsp;Jaime González-Domínguez,&nbsp;Justo García-Sanz-Calcedo","doi":"10.1080/17434440.2023.2243208","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Proper maintenance of electro-medical devices is crucial for the quality of care to patients and the economic performance of healthcare organizations. This research aims to identify the interaction between Ultrasound scanners (US) maintenance variables as a function of maintenance indicators: US in service or decommissioned, excessive number of failures, and failure rate. Knowing those interactions, specific maintenance measures will be developed to improve the reliability of the US.</p><p><strong>Research design and methods: </strong>Multifactor Dimensionality Reduction (MDR) method was eployed to analyze data from 222 US and their four-year maintenance history. Models were developed based on the variables with the greatest influence on maintenance indicators, where US were classified according to the associated risk.</p><p><strong>Results: </strong>US with more than one major failure or at least one major component replacement had up to 496.4% more failures than the average. Failure rate increased by up to 188.7% over the average for those US with more than three moderate failures, three replacements, or both.</p><p><strong>Conclusions: </strong>This study identifies and quantifies the causes of risk to establish a specific maintenance plan for US. It helps to better understand the degradation of US to optimize their operation and maintenance.</p>","PeriodicalId":12330,"journal":{"name":"Expert Review of Medical Devices","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Interaction between maintenance variables of medical ultrasound scanners through multifactor dimensionality reduction.\",\"authors\":\"Alejandro Prieto-Fernández,&nbsp;Gonzalo Sánchez-Barroso,&nbsp;Jaime González-Domínguez,&nbsp;Justo García-Sanz-Calcedo\",\"doi\":\"10.1080/17434440.2023.2243208\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Proper maintenance of electro-medical devices is crucial for the quality of care to patients and the economic performance of healthcare organizations. This research aims to identify the interaction between Ultrasound scanners (US) maintenance variables as a function of maintenance indicators: US in service or decommissioned, excessive number of failures, and failure rate. Knowing those interactions, specific maintenance measures will be developed to improve the reliability of the US.</p><p><strong>Research design and methods: </strong>Multifactor Dimensionality Reduction (MDR) method was eployed to analyze data from 222 US and their four-year maintenance history. Models were developed based on the variables with the greatest influence on maintenance indicators, where US were classified according to the associated risk.</p><p><strong>Results: </strong>US with more than one major failure or at least one major component replacement had up to 496.4% more failures than the average. Failure rate increased by up to 188.7% over the average for those US with more than three moderate failures, three replacements, or both.</p><p><strong>Conclusions: </strong>This study identifies and quantifies the causes of risk to establish a specific maintenance plan for US. It helps to better understand the degradation of US to optimize their operation and maintenance.</p>\",\"PeriodicalId\":12330,\"journal\":{\"name\":\"Expert Review of Medical Devices\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Expert Review of Medical Devices\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/17434440.2023.2243208\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/8/7 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert Review of Medical Devices","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/17434440.2023.2243208","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/7 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:电子医疗设备的正确维护对患者的护理质量和医疗机构的经济绩效至关重要。本研究旨在确定超声扫描仪(US)维护变量与维护指标之间的相互作用:US在役或退役、故障次数过多和故障率。了解这些相互作用,将制定具体的维护措施来提高美国的可靠性。研究设计和方法:采用多因素降维(MDR)方法分析222名美国及其四年维护历史的数据。模型是基于对维护指标影响最大的变量开发的,其中US根据相关风险进行分类。结果:美国发生一次以上重大故障或至少更换一次主要部件的故障率比平均水平高出496.4%。对于三次以上中度故障、三次更换或两者兼有的美国,故障率比平均水平上升了188.7%。结论:本研究通过识别和量化风险原因,为US制定具体的维护计划。有助于更好地了解US的退化情况,优化其操作和维护。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Interaction between maintenance variables of medical ultrasound scanners through multifactor dimensionality reduction.

Background: Proper maintenance of electro-medical devices is crucial for the quality of care to patients and the economic performance of healthcare organizations. This research aims to identify the interaction between Ultrasound scanners (US) maintenance variables as a function of maintenance indicators: US in service or decommissioned, excessive number of failures, and failure rate. Knowing those interactions, specific maintenance measures will be developed to improve the reliability of the US.

Research design and methods: Multifactor Dimensionality Reduction (MDR) method was eployed to analyze data from 222 US and their four-year maintenance history. Models were developed based on the variables with the greatest influence on maintenance indicators, where US were classified according to the associated risk.

Results: US with more than one major failure or at least one major component replacement had up to 496.4% more failures than the average. Failure rate increased by up to 188.7% over the average for those US with more than three moderate failures, three replacements, or both.

Conclusions: This study identifies and quantifies the causes of risk to establish a specific maintenance plan for US. It helps to better understand the degradation of US to optimize their operation and maintenance.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Expert Review of Medical Devices
Expert Review of Medical Devices 医学-工程:生物医学
CiteScore
5.90
自引率
3.20%
发文量
69
审稿时长
6-12 weeks
期刊介绍: The journal serves the device research community by providing a comprehensive body of high-quality information from leading experts, all subject to rigorous peer review. The Expert Review format is specially structured to optimize the value of the information to reader. Comprehensive coverage by each author in a key area of research or clinical practice is augmented by the following sections: Expert commentary - a personal view on the most effective or promising strategies Five-year view - a clear perspective of future prospects within a realistic timescale Key issues - an executive summary cutting to the author''s most critical points In addition to the Review program, each issue also features Medical Device Profiles - objective assessments of specific devices in development or clinical use to help inform clinical practice. There are also Perspectives - overviews highlighting areas of current debate and controversy, together with reports from the conference scene and invited Editorials.
期刊最新文献
Future perspectives and challenges of artificial intelligence implementation in remote monitoring of cardiac implantable electronic devices. His bundle pacing combined with atrioventricular node ablation for atrial fibrillation: a systematic review and meta-analysis. Complications after peripherally inserted central catheter versus central venous catheter implantation in intensive care unit: propensity score analysis using a nationwide database. Thoracic impedance monitoring in heart failure: from theory to practice. Dynamic versus standard bougies for tracheal intubation with direct or indirect laryngoscopy in simulated or real scenarios: a systematic review and meta-analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1