{"title":"标准化人工老化后的基台去除扭矩和种植体锥形表面形态变化:体外研究","authors":"Zhihao Zhai DDS, PhD , Tamaki Nakano DDS, PhD , Yuming Chen DDS , Shota Watanabe DDS, PhD , Takashi Matsuoka DDS, PhD , Shoichi Ishigaki DDS, PhD","doi":"10.1016/j.prosdent.2022.11.016","DOIUrl":null,"url":null,"abstract":"<div><h3>Statement of problem</h3><div><span>Zirconia </span>abutments have become popular as they provide favorable esthetic outcomes. However, studies investigating how abutment material affects abutment screw torque performance and implant conical surface morphological changes in internal conical connection systems are scarce.</div></div><div><h3>Purpose</h3><div>The purpose of this in vitro study was to investigate the influence of abutment material on abutment removal torque and implant conical surface morphological changes in internal conical connection implant–abutment assemblies of 2 diameters after simulated long-term oral use.</div></div><div><h3>Material and methods</h3><div><span><span>Thirty abutments of 3 materials (1-piece titanium, 1-piece zirconia, zirconia with alloy base) and 2 diameters (regular, narrow) made by the original manufacturer were connected to internal conical connection implants and subjected to a standardized artificial aging process consisting of thermal cycling and mechanical cyclic loading with parameters corresponding to anterior and posterior </span>mastication<span> scenarios simulating long-term oral use. An abutment removal torque test was done before and after aging. Morphological changes in the implant conical contact surface were observed with a scanning electron microscope (SEM). Initial and after-aging torque loss values were calculated and analyzed separately with 1-way ANOVA and Tukey HSD </span></span>post hoc tests (α=.05).</div></div><div><h3>Results</h3><div>All specimens survived artificial aging. For initial and after-aging torque loss, the 1-piece zirconia groups showed significantly greater values (<em>P</em><.001) for both diameters. In the SEM observation, the 1-piece zirconia groups showed distinct widespread surface damage while the other groups exhibited only minor damages.</div></div><div><h3>Conclusions</h3><div>Regardless of diameter, 1-piece zirconia abutments tend to induce more abutment removal torque loss and implant conical surface morphological changes than those with metal connections, both initially and after simulated long-term oral use. Zirconia abutments with an alloy base performed similarly to 1-piece titanium abutments.</div></div>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":"132 5","pages":"Pages 1005-1013"},"PeriodicalIF":4.3000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Abutment removal torque and implant conical surface morphological changes after standardized artificial aging: An in vitro study\",\"authors\":\"Zhihao Zhai DDS, PhD , Tamaki Nakano DDS, PhD , Yuming Chen DDS , Shota Watanabe DDS, PhD , Takashi Matsuoka DDS, PhD , Shoichi Ishigaki DDS, PhD\",\"doi\":\"10.1016/j.prosdent.2022.11.016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Statement of problem</h3><div><span>Zirconia </span>abutments have become popular as they provide favorable esthetic outcomes. However, studies investigating how abutment material affects abutment screw torque performance and implant conical surface morphological changes in internal conical connection systems are scarce.</div></div><div><h3>Purpose</h3><div>The purpose of this in vitro study was to investigate the influence of abutment material on abutment removal torque and implant conical surface morphological changes in internal conical connection implant–abutment assemblies of 2 diameters after simulated long-term oral use.</div></div><div><h3>Material and methods</h3><div><span><span>Thirty abutments of 3 materials (1-piece titanium, 1-piece zirconia, zirconia with alloy base) and 2 diameters (regular, narrow) made by the original manufacturer were connected to internal conical connection implants and subjected to a standardized artificial aging process consisting of thermal cycling and mechanical cyclic loading with parameters corresponding to anterior and posterior </span>mastication<span> scenarios simulating long-term oral use. An abutment removal torque test was done before and after aging. Morphological changes in the implant conical contact surface were observed with a scanning electron microscope (SEM). Initial and after-aging torque loss values were calculated and analyzed separately with 1-way ANOVA and Tukey HSD </span></span>post hoc tests (α=.05).</div></div><div><h3>Results</h3><div>All specimens survived artificial aging. For initial and after-aging torque loss, the 1-piece zirconia groups showed significantly greater values (<em>P</em><.001) for both diameters. In the SEM observation, the 1-piece zirconia groups showed distinct widespread surface damage while the other groups exhibited only minor damages.</div></div><div><h3>Conclusions</h3><div>Regardless of diameter, 1-piece zirconia abutments tend to induce more abutment removal torque loss and implant conical surface morphological changes than those with metal connections, both initially and after simulated long-term oral use. Zirconia abutments with an alloy base performed similarly to 1-piece titanium abutments.</div></div>\",\"PeriodicalId\":16866,\"journal\":{\"name\":\"Journal of Prosthetic Dentistry\",\"volume\":\"132 5\",\"pages\":\"Pages 1005-1013\"},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Prosthetic Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0022391322007387\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022391322007387","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Abutment removal torque and implant conical surface morphological changes after standardized artificial aging: An in vitro study
Statement of problem
Zirconia abutments have become popular as they provide favorable esthetic outcomes. However, studies investigating how abutment material affects abutment screw torque performance and implant conical surface morphological changes in internal conical connection systems are scarce.
Purpose
The purpose of this in vitro study was to investigate the influence of abutment material on abutment removal torque and implant conical surface morphological changes in internal conical connection implant–abutment assemblies of 2 diameters after simulated long-term oral use.
Material and methods
Thirty abutments of 3 materials (1-piece titanium, 1-piece zirconia, zirconia with alloy base) and 2 diameters (regular, narrow) made by the original manufacturer were connected to internal conical connection implants and subjected to a standardized artificial aging process consisting of thermal cycling and mechanical cyclic loading with parameters corresponding to anterior and posterior mastication scenarios simulating long-term oral use. An abutment removal torque test was done before and after aging. Morphological changes in the implant conical contact surface were observed with a scanning electron microscope (SEM). Initial and after-aging torque loss values were calculated and analyzed separately with 1-way ANOVA and Tukey HSD post hoc tests (α=.05).
Results
All specimens survived artificial aging. For initial and after-aging torque loss, the 1-piece zirconia groups showed significantly greater values (P<.001) for both diameters. In the SEM observation, the 1-piece zirconia groups showed distinct widespread surface damage while the other groups exhibited only minor damages.
Conclusions
Regardless of diameter, 1-piece zirconia abutments tend to induce more abutment removal torque loss and implant conical surface morphological changes than those with metal connections, both initially and after simulated long-term oral use. Zirconia abutments with an alloy base performed similarly to 1-piece titanium abutments.
期刊介绍:
The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.