不平衡电网中基于mmc的光伏系统功率失配消除策略

H. Bayat, A. Yazdani
{"title":"不平衡电网中基于mmc的光伏系统功率失配消除策略","authors":"H. Bayat, A. Yazdani","doi":"10.1109/EPEC.2018.8598280","DOIUrl":null,"url":null,"abstract":"Application of modular multilevel converter (MMC) for grid integration of photovoltaic (PV) generators has gained much attention lately. This paper proposes a modified power mismatch elimination strategy for an MMC-based PV system. Although the existing power mismatch elimination strategy based on internal power flow of the MMC is capable of eliminating power mismatches in a perfectly balanced power system, it will fail to do so if the grid voltage is unbalanced at point of common coupling (PCC). The proposed modified power mismatch elimination strategy, utilizes the internal power flow of the MMC-based PV system to ensure that the converter leg connected to grid phase with higher voltage delivers higher power to the grid and the leg connected to the phase with lower voltage delivers less power to the grid. As a result, the currents delivered to the host grid become balanced and symmetrical in spite of existing power mismatches and unbalanced grid voltage. The effectiveness of the proposed modified power mismatch elimination strategy is demonstrated by time-domain simulations conducted on a model of the PV system in PSCAD/EMTDC software environment.","PeriodicalId":265297,"journal":{"name":"2018 IEEE Electrical Power and Energy Conference (EPEC)","volume":"43 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"A Power Mismatch Elimination Strategy for an MMC-based PV System in Unbalanced Grids\",\"authors\":\"H. Bayat, A. Yazdani\",\"doi\":\"10.1109/EPEC.2018.8598280\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Application of modular multilevel converter (MMC) for grid integration of photovoltaic (PV) generators has gained much attention lately. This paper proposes a modified power mismatch elimination strategy for an MMC-based PV system. Although the existing power mismatch elimination strategy based on internal power flow of the MMC is capable of eliminating power mismatches in a perfectly balanced power system, it will fail to do so if the grid voltage is unbalanced at point of common coupling (PCC). The proposed modified power mismatch elimination strategy, utilizes the internal power flow of the MMC-based PV system to ensure that the converter leg connected to grid phase with higher voltage delivers higher power to the grid and the leg connected to the phase with lower voltage delivers less power to the grid. As a result, the currents delivered to the host grid become balanced and symmetrical in spite of existing power mismatches and unbalanced grid voltage. The effectiveness of the proposed modified power mismatch elimination strategy is demonstrated by time-domain simulations conducted on a model of the PV system in PSCAD/EMTDC software environment.\",\"PeriodicalId\":265297,\"journal\":{\"name\":\"2018 IEEE Electrical Power and Energy Conference (EPEC)\",\"volume\":\"43 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE Electrical Power and Energy Conference (EPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPEC.2018.8598280\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Electrical Power and Energy Conference (EPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPEC.2018.8598280","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

模块化多电平变流器(MMC)在光伏发电机组并网中的应用近年来备受关注。针对基于mmc的光伏系统,提出了一种改进的功率失配消除策略。虽然现有的基于MMC内部潮流的功率失配消除策略能够在完全平衡的电力系统中消除功率失配,但如果在共耦合点(PCC)电网电压不平衡,则无法消除功率失配。提出的修正功率失配消除策略,利用基于mmc的光伏系统的内部功率流,确保与高电压相连接的变流器分支向电网输出更高的功率,而与低电压相连接的分支向电网输出更少的功率。因此,尽管存在功率不匹配和电网电压不平衡,但输送到主电网的电流仍然保持平衡和对称。在PSCAD/EMTDC软件环境下对光伏系统模型进行时域仿真,验证了改进后的功率失配消除策略的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Power Mismatch Elimination Strategy for an MMC-based PV System in Unbalanced Grids
Application of modular multilevel converter (MMC) for grid integration of photovoltaic (PV) generators has gained much attention lately. This paper proposes a modified power mismatch elimination strategy for an MMC-based PV system. Although the existing power mismatch elimination strategy based on internal power flow of the MMC is capable of eliminating power mismatches in a perfectly balanced power system, it will fail to do so if the grid voltage is unbalanced at point of common coupling (PCC). The proposed modified power mismatch elimination strategy, utilizes the internal power flow of the MMC-based PV system to ensure that the converter leg connected to grid phase with higher voltage delivers higher power to the grid and the leg connected to the phase with lower voltage delivers less power to the grid. As a result, the currents delivered to the host grid become balanced and symmetrical in spite of existing power mismatches and unbalanced grid voltage. The effectiveness of the proposed modified power mismatch elimination strategy is demonstrated by time-domain simulations conducted on a model of the PV system in PSCAD/EMTDC software environment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Power Mismatch Elimination Strategy for an MMC-based PV System in Unbalanced Grids Implementation and Testing of a Hybrid Protection Scheme for Active Distribution Network Evaluation of Parametric Statistical Models for Wind Speed Probability Density Estimation Modeling of Ferroresonance Phenomena in MV Networks Emulating Subsynchronous Resonance using Hardware and Software Implementation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1