M. AboRas, G. Engelmann, D. May, M. Rothermund, R. Schacht, B. Wunderle, H. Oppermann, T. Winkler, S. Rzepka, B. Michel
{"title":"薄膜热测试芯片的研制及其集成到热界面表征测试系统中","authors":"M. AboRas, G. Engelmann, D. May, M. Rothermund, R. Schacht, B. Wunderle, H. Oppermann, T. Winkler, S. Rzepka, B. Michel","doi":"10.1109/THERMINIC.2013.6675188","DOIUrl":null,"url":null,"abstract":"This paper deals with the development und fabrication of a thermal test chip (TTC) to be used for thermal characterisation and qualification of materials and packages. The TTC is designed as a modular chip with the smallest full functional chip cell of 3.2mm × 3.2mm and consists of a heater structure and a temperature sensor. The chips can be applied in any required matrix. Heater and temperature sensors are realised by a 70 nm single Titanium layer as adhesion and barrier layer. The Titanium is structured a on 670μm silicon wafer by the cost efficient thin film technology. 3×3 matrix chips have been sawn, assembled on a FR4 substrate by flip chip technology and integrated into a test stand for characterisation of thermal interface materials (TIMA Tester). The calibration curves of the temperature sensors show 4-time higher sensitivity then Si diodes. The homogeneity of the surface temperature was checked by the Lock-In infra-red thermography and compared with a commercial thermo test chip.","PeriodicalId":369128,"journal":{"name":"19th International Workshop on Thermal Investigations of ICs and Systems (THERMINIC)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Development and fabrication of a thin film thermo test chip and its integration into a test system for thermal interface characterization\",\"authors\":\"M. AboRas, G. Engelmann, D. May, M. Rothermund, R. Schacht, B. Wunderle, H. Oppermann, T. Winkler, S. Rzepka, B. Michel\",\"doi\":\"10.1109/THERMINIC.2013.6675188\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with the development und fabrication of a thermal test chip (TTC) to be used for thermal characterisation and qualification of materials and packages. The TTC is designed as a modular chip with the smallest full functional chip cell of 3.2mm × 3.2mm and consists of a heater structure and a temperature sensor. The chips can be applied in any required matrix. Heater and temperature sensors are realised by a 70 nm single Titanium layer as adhesion and barrier layer. The Titanium is structured a on 670μm silicon wafer by the cost efficient thin film technology. 3×3 matrix chips have been sawn, assembled on a FR4 substrate by flip chip technology and integrated into a test stand for characterisation of thermal interface materials (TIMA Tester). The calibration curves of the temperature sensors show 4-time higher sensitivity then Si diodes. The homogeneity of the surface temperature was checked by the Lock-In infra-red thermography and compared with a commercial thermo test chip.\",\"PeriodicalId\":369128,\"journal\":{\"name\":\"19th International Workshop on Thermal Investigations of ICs and Systems (THERMINIC)\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"19th International Workshop on Thermal Investigations of ICs and Systems (THERMINIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/THERMINIC.2013.6675188\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"19th International Workshop on Thermal Investigations of ICs and Systems (THERMINIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/THERMINIC.2013.6675188","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development and fabrication of a thin film thermo test chip and its integration into a test system for thermal interface characterization
This paper deals with the development und fabrication of a thermal test chip (TTC) to be used for thermal characterisation and qualification of materials and packages. The TTC is designed as a modular chip with the smallest full functional chip cell of 3.2mm × 3.2mm and consists of a heater structure and a temperature sensor. The chips can be applied in any required matrix. Heater and temperature sensors are realised by a 70 nm single Titanium layer as adhesion and barrier layer. The Titanium is structured a on 670μm silicon wafer by the cost efficient thin film technology. 3×3 matrix chips have been sawn, assembled on a FR4 substrate by flip chip technology and integrated into a test stand for characterisation of thermal interface materials (TIMA Tester). The calibration curves of the temperature sensors show 4-time higher sensitivity then Si diodes. The homogeneity of the surface temperature was checked by the Lock-In infra-red thermography and compared with a commercial thermo test chip.