物联网模块的热功率外壳

Jared A. Shipman, S. Chigullapalli, J. Mata, Thomas A. Martin
{"title":"物联网模块的热功率外壳","authors":"Jared A. Shipman, S. Chigullapalli, J. Mata, Thomas A. Martin","doi":"10.1109/SEMI-THERM.2017.7896914","DOIUrl":null,"url":null,"abstract":"IoT space is very dynamic and there is a multidimensional matrix of end-customer use-cases possible with the same module. A simple spec of Tcasemax and Thermal Design Power (TDP) will no longer suffice for an accurate design of the system complexity. The basic principle in this paper is to create a standard temperature and power envelope based on two broad classification of use cases: Application Processing Only (AP) and Application + Communication Processing (AP+CP). The final curves will change based on the thermal limiters, the type of thermal solution used, stack-up details, etc. All analysis is done using a systematic system engineering approach.","PeriodicalId":442782,"journal":{"name":"2017 33rd Thermal Measurement, Modeling & Management Symposium (SEMI-THERM)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Thermal power envelope for IoT modules\",\"authors\":\"Jared A. Shipman, S. Chigullapalli, J. Mata, Thomas A. Martin\",\"doi\":\"10.1109/SEMI-THERM.2017.7896914\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"IoT space is very dynamic and there is a multidimensional matrix of end-customer use-cases possible with the same module. A simple spec of Tcasemax and Thermal Design Power (TDP) will no longer suffice for an accurate design of the system complexity. The basic principle in this paper is to create a standard temperature and power envelope based on two broad classification of use cases: Application Processing Only (AP) and Application + Communication Processing (AP+CP). The final curves will change based on the thermal limiters, the type of thermal solution used, stack-up details, etc. All analysis is done using a systematic system engineering approach.\",\"PeriodicalId\":442782,\"journal\":{\"name\":\"2017 33rd Thermal Measurement, Modeling & Management Symposium (SEMI-THERM)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 33rd Thermal Measurement, Modeling & Management Symposium (SEMI-THERM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SEMI-THERM.2017.7896914\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 33rd Thermal Measurement, Modeling & Management Symposium (SEMI-THERM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SEMI-THERM.2017.7896914","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

物联网空间是非常动态的,有一个多维矩阵的终端客户用例可能与相同的模块。简单的Tcasemax和热设计功率(TDP)规格将不再足以精确设计系统的复杂性。本文的基本原理是基于两种广泛的用例分类:仅应用程序处理(AP)和应用程序+通信处理(AP+CP)来创建标准的温度和功率包络。最终的曲线将根据热限制器、使用的热解决方案类型、堆叠细节等而变化。所有的分析都是使用系统的系统工程方法完成的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Thermal power envelope for IoT modules
IoT space is very dynamic and there is a multidimensional matrix of end-customer use-cases possible with the same module. A simple spec of Tcasemax and Thermal Design Power (TDP) will no longer suffice for an accurate design of the system complexity. The basic principle in this paper is to create a standard temperature and power envelope based on two broad classification of use cases: Application Processing Only (AP) and Application + Communication Processing (AP+CP). The final curves will change based on the thermal limiters, the type of thermal solution used, stack-up details, etc. All analysis is done using a systematic system engineering approach.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An experimental and theoretical investigation of the effects of supply air conditions on computational efficiency in data centers employing aisle containment Performance of a mixed mode air handling unit for direct liquid-cooled servers High performance computing (HPC) 3 dimensional integrated (3DI) thermal test vehicle validation effort Rack-level study of hybrid cooled servers using warm water cooling for distributed vs. centralized pumping systems A new hybrid heat sink with impinging micro-jet arrays and microchannels fabricated using high volume additive manufacturing
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1