有功配电网混合保护方案的实现与试验

A. Pathirana, A. Rajapakse, A. C. Adewole
{"title":"有功配电网混合保护方案的实现与试验","authors":"A. Pathirana, A. Rajapakse, A. C. Adewole","doi":"10.1109/EPEC.2018.8598293","DOIUrl":null,"url":null,"abstract":"This paper describes implementation of a hybrid protection scheme consisting of both transient-based protection and conventional time over-current protection in a laboratory environment. Transient base protection scheme uses initial polarities of current transients to determine whether a fault is in the protected zone, while the conventional protection scheme confirms the existence of fault. The scope of testing is limited to testing the functionality and generic performance characteristics of hybrid protection scheme. The implementation consists of both hardware and software sections including power system modelling, sensor designing and programming of the conventional relay logic. The operation of the hybrid protection scheme is demonstrated using hardware-in-the-loop simulations.","PeriodicalId":265297,"journal":{"name":"2018 IEEE Electrical Power and Energy Conference (EPEC)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Implementation and Testing of a Hybrid Protection Scheme for Active Distribution Network\",\"authors\":\"A. Pathirana, A. Rajapakse, A. C. Adewole\",\"doi\":\"10.1109/EPEC.2018.8598293\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes implementation of a hybrid protection scheme consisting of both transient-based protection and conventional time over-current protection in a laboratory environment. Transient base protection scheme uses initial polarities of current transients to determine whether a fault is in the protected zone, while the conventional protection scheme confirms the existence of fault. The scope of testing is limited to testing the functionality and generic performance characteristics of hybrid protection scheme. The implementation consists of both hardware and software sections including power system modelling, sensor designing and programming of the conventional relay logic. The operation of the hybrid protection scheme is demonstrated using hardware-in-the-loop simulations.\",\"PeriodicalId\":265297,\"journal\":{\"name\":\"2018 IEEE Electrical Power and Energy Conference (EPEC)\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE Electrical Power and Energy Conference (EPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPEC.2018.8598293\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Electrical Power and Energy Conference (EPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPEC.2018.8598293","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文介绍了一种由瞬态保护和常规时间过流保护组成的混合保护方案在实验室环境中的实现。暂态基极保护方案利用电流暂态的初始极性来判断故障是否在保护区内,而常规保护方案则确定故障是否存在。测试范围限于测试混合保护方案的功能和一般性能特征。实现包括硬件和软件两部分,包括电力系统建模、传感器设计和传统继电器逻辑编程。通过硬件在环仿真验证了混合保护方案的运行。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Implementation and Testing of a Hybrid Protection Scheme for Active Distribution Network
This paper describes implementation of a hybrid protection scheme consisting of both transient-based protection and conventional time over-current protection in a laboratory environment. Transient base protection scheme uses initial polarities of current transients to determine whether a fault is in the protected zone, while the conventional protection scheme confirms the existence of fault. The scope of testing is limited to testing the functionality and generic performance characteristics of hybrid protection scheme. The implementation consists of both hardware and software sections including power system modelling, sensor designing and programming of the conventional relay logic. The operation of the hybrid protection scheme is demonstrated using hardware-in-the-loop simulations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Power Mismatch Elimination Strategy for an MMC-based PV System in Unbalanced Grids Implementation and Testing of a Hybrid Protection Scheme for Active Distribution Network Evaluation of Parametric Statistical Models for Wind Speed Probability Density Estimation Modeling of Ferroresonance Phenomena in MV Networks Emulating Subsynchronous Resonance using Hardware and Software Implementation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1