计算机辅助灯温测量装置和最大灯形温度

D. Li
{"title":"计算机辅助灯温测量装置和最大灯形温度","authors":"D. Li","doi":"10.1109/IAS.1993.299208","DOIUrl":null,"url":null,"abstract":"Recognizing the limitations of existing test equipment the Canadian Standards Association developed a computer-aided lamp temperature measuring apparatus. This equipment incorporates a simple approach to detecting thermal characteristics of tungsten filament lamps. The key element of this equipment is a data acquisition system that compiles measured test data and selects the maximum temperatures. The test data can be used to develop an empirical equation for determining the maximum temperatures of new tungsten filament lamps. This equation will compute maximum permissible profile temperature limits for new lamps with different bulb size or different lamp wattages.<<ETX>>","PeriodicalId":345027,"journal":{"name":"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Computer-aided lamp temperature measuring apparatus and maximum lamp profile temperature\",\"authors\":\"D. Li\",\"doi\":\"10.1109/IAS.1993.299208\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Recognizing the limitations of existing test equipment the Canadian Standards Association developed a computer-aided lamp temperature measuring apparatus. This equipment incorporates a simple approach to detecting thermal characteristics of tungsten filament lamps. The key element of this equipment is a data acquisition system that compiles measured test data and selects the maximum temperatures. The test data can be used to develop an empirical equation for determining the maximum temperatures of new tungsten filament lamps. This equation will compute maximum permissible profile temperature limits for new lamps with different bulb size or different lamp wattages.<<ETX>>\",\"PeriodicalId\":345027,\"journal\":{\"name\":\"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.1993.299208\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1993.299208","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

认识到现有测试设备的局限性,加拿大标准协会开发了一种计算机辅助灯温测量装置。该设备采用一种简单的方法来检测钨丝灯的热特性。该设备的关键元件是数据采集系统,该系统可以编译测量的测试数据并选择最高温度。试验数据可用于建立确定新型钨丝灯最高温度的经验公式。此公式将计算不同灯泡尺寸或不同灯瓦数的新灯的最大允许外形温度限制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Computer-aided lamp temperature measuring apparatus and maximum lamp profile temperature
Recognizing the limitations of existing test equipment the Canadian Standards Association developed a computer-aided lamp temperature measuring apparatus. This equipment incorporates a simple approach to detecting thermal characteristics of tungsten filament lamps. The key element of this equipment is a data acquisition system that compiles measured test data and selects the maximum temperatures. The test data can be used to develop an empirical equation for determining the maximum temperatures of new tungsten filament lamps. This equation will compute maximum permissible profile temperature limits for new lamps with different bulb size or different lamp wattages.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Maximum torque control of an induction machine in the field weakening region Production of O/W type uniformly sized droplets using a convergent AC electric field The effect of temperature on starting and stabilization of compact fluorescent systems A low cost compact CCD grating spectrometer Surface handling effects of fabricating thin dielectric film HDPE on TSDC analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1