{"title":"考虑负载扰动影响的SM DTC-SVM IM控制性能研究","authors":"F. B. Salem, N. Derbel","doi":"10.1109/SSD.2016.7473722","DOIUrl":null,"url":null,"abstract":"This work is developed within the objective to discard load disturbances effects on the induction machine drives under DTC-SVM control. The paper is devoted to the presentation of a comparison study between two DTC-SVM strategies applied to the speed control of an induction motor: (i) a DTC-SVM control using PI controllers and (ii) a DTC-SVM control using sliding mode controllers without and with gain load estimator. Firstly, mathematical fundamentals of both strategies are briefly formulated. Then, and considering a linear torque case, an adaptive load torque estimator is inserted in the speed loop in order to overcome the problem of load disturbance effects. Finally, simulation results dealing with steady-state as well as dynamic behaviors of the induction motor under both DTC-SVM strategies are presented and compared. Simulation results clearly show that SM DTC-SVM strategy with load estimator offers the best performances and the load disturbances effects can be completely discarded.","PeriodicalId":149580,"journal":{"name":"2016 13th International Multi-Conference on Systems, Signals & Devices (SSD)","volume":"80 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Investigation of SM DTC-SVM performances of IM control considering load disturbances effects\",\"authors\":\"F. B. Salem, N. Derbel\",\"doi\":\"10.1109/SSD.2016.7473722\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work is developed within the objective to discard load disturbances effects on the induction machine drives under DTC-SVM control. The paper is devoted to the presentation of a comparison study between two DTC-SVM strategies applied to the speed control of an induction motor: (i) a DTC-SVM control using PI controllers and (ii) a DTC-SVM control using sliding mode controllers without and with gain load estimator. Firstly, mathematical fundamentals of both strategies are briefly formulated. Then, and considering a linear torque case, an adaptive load torque estimator is inserted in the speed loop in order to overcome the problem of load disturbance effects. Finally, simulation results dealing with steady-state as well as dynamic behaviors of the induction motor under both DTC-SVM strategies are presented and compared. Simulation results clearly show that SM DTC-SVM strategy with load estimator offers the best performances and the load disturbances effects can be completely discarded.\",\"PeriodicalId\":149580,\"journal\":{\"name\":\"2016 13th International Multi-Conference on Systems, Signals & Devices (SSD)\",\"volume\":\"80 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-03-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 13th International Multi-Conference on Systems, Signals & Devices (SSD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SSD.2016.7473722\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 13th International Multi-Conference on Systems, Signals & Devices (SSD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SSD.2016.7473722","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Investigation of SM DTC-SVM performances of IM control considering load disturbances effects
This work is developed within the objective to discard load disturbances effects on the induction machine drives under DTC-SVM control. The paper is devoted to the presentation of a comparison study between two DTC-SVM strategies applied to the speed control of an induction motor: (i) a DTC-SVM control using PI controllers and (ii) a DTC-SVM control using sliding mode controllers without and with gain load estimator. Firstly, mathematical fundamentals of both strategies are briefly formulated. Then, and considering a linear torque case, an adaptive load torque estimator is inserted in the speed loop in order to overcome the problem of load disturbance effects. Finally, simulation results dealing with steady-state as well as dynamic behaviors of the induction motor under both DTC-SVM strategies are presented and compared. Simulation results clearly show that SM DTC-SVM strategy with load estimator offers the best performances and the load disturbances effects can be completely discarded.