一种用于正交电流复用神经放大器的亚阈值电压阶梯整流器

Changhyuk Lee, Ben Johnson, A. Molnar
{"title":"一种用于正交电流复用神经放大器的亚阈值电压阶梯整流器","authors":"Changhyuk Lee, Ben Johnson, A. Molnar","doi":"10.1109/BioCAS.2013.6679713","DOIUrl":null,"url":null,"abstract":"We demonstrate an inductively powered, orthogonal current-reuse multi-channel amplifier for power-efficient neural recording. The power rectifier uses the input swing as a self-synchronous charge pump, making it a fully passive, full-wave ladder rectifier. The rectifier supplies 10.37μW at 1.224V to the multi-channel amplifier, which includes bias generation. The prototype device is fabricated in a TSMC 65nm CMOS process, with an active area of 0.107mm2. The maximum measured power conversion efficiency (PCE) is 16.58% with a 184mV input amplitude.","PeriodicalId":344317,"journal":{"name":"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A sub-threshold voltage ladder rectifier for orthogonal current-reuse neural amplifier\",\"authors\":\"Changhyuk Lee, Ben Johnson, A. Molnar\",\"doi\":\"10.1109/BioCAS.2013.6679713\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We demonstrate an inductively powered, orthogonal current-reuse multi-channel amplifier for power-efficient neural recording. The power rectifier uses the input swing as a self-synchronous charge pump, making it a fully passive, full-wave ladder rectifier. The rectifier supplies 10.37μW at 1.224V to the multi-channel amplifier, which includes bias generation. The prototype device is fabricated in a TSMC 65nm CMOS process, with an active area of 0.107mm2. The maximum measured power conversion efficiency (PCE) is 16.58% with a 184mV input amplitude.\",\"PeriodicalId\":344317,\"journal\":{\"name\":\"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BioCAS.2013.6679713\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BioCAS.2013.6679713","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

我们演示了一种用于高能效神经记录的电感供电、正交电流复用多通道放大器。功率整流器利用输入摆幅作为自同步电荷泵,使其成为全无源、全波阶梯整流器。整流器在1.224V电压下为多路放大器提供10.37μW,其中包括偏置产生。该原型器件采用台积电65nm CMOS工艺制造,有效面积为0.107mm2。当输入幅值为184mV时,最大测量功率转换效率(PCE)为16.58%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A sub-threshold voltage ladder rectifier for orthogonal current-reuse neural amplifier
We demonstrate an inductively powered, orthogonal current-reuse multi-channel amplifier for power-efficient neural recording. The power rectifier uses the input swing as a self-synchronous charge pump, making it a fully passive, full-wave ladder rectifier. The rectifier supplies 10.37μW at 1.224V to the multi-channel amplifier, which includes bias generation. The prototype device is fabricated in a TSMC 65nm CMOS process, with an active area of 0.107mm2. The maximum measured power conversion efficiency (PCE) is 16.58% with a 184mV input amplitude.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Multi-electrode amperometric biosensor for neurotransmitters detection A portable hardware implementation for temporal laser speckle imaging Automatic detection of sleep spindles using Teager energy and spectral edge frequency A 430nW 64nV/vHz current-reuse telescopic amplifier for neural recording applications Output stage of a current-steering multipolar and multisite deep brain stimulator
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1