Markus Andresen, Marco Liserre, F. Fuchs, N. Hoffmann
{"title":"带LCL滤波器的PWM变换器的网格自适应控制器设计","authors":"Markus Andresen, Marco Liserre, F. Fuchs, N. Hoffmann","doi":"10.1109/IECON.2015.7392671","DOIUrl":null,"url":null,"abstract":"The system resonance frequency of a grid connected inverter with LCL filter depends on the filter parameters and the time varying grid impedance. To obtain stability and to preserve good dynamic behavior of the system, grid impedance adaptation of the current controller is proposed. The design of the current controller is described and the adaptation strategy to prevent the excitation of the system resonance frequency during grid-impedance changes is introduced. The actual grid impedance is estimated by an extended Kalman filter (EKF) and a Luenberger observer allows to use the same number of voltage and current sensors as in conventional PI controllers. The proposed control method provides the possibility to tune the controller dynamics independently from the grid impedance. The theoretical analysis is validated with laboratory measurements.","PeriodicalId":190550,"journal":{"name":"IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Design of a grid adaptive controller for PWM converters with LCL filters\",\"authors\":\"Markus Andresen, Marco Liserre, F. Fuchs, N. Hoffmann\",\"doi\":\"10.1109/IECON.2015.7392671\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The system resonance frequency of a grid connected inverter with LCL filter depends on the filter parameters and the time varying grid impedance. To obtain stability and to preserve good dynamic behavior of the system, grid impedance adaptation of the current controller is proposed. The design of the current controller is described and the adaptation strategy to prevent the excitation of the system resonance frequency during grid-impedance changes is introduced. The actual grid impedance is estimated by an extended Kalman filter (EKF) and a Luenberger observer allows to use the same number of voltage and current sensors as in conventional PI controllers. The proposed control method provides the possibility to tune the controller dynamics independently from the grid impedance. The theoretical analysis is validated with laboratory measurements.\",\"PeriodicalId\":190550,\"journal\":{\"name\":\"IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IECON.2015.7392671\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.2015.7392671","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design of a grid adaptive controller for PWM converters with LCL filters
The system resonance frequency of a grid connected inverter with LCL filter depends on the filter parameters and the time varying grid impedance. To obtain stability and to preserve good dynamic behavior of the system, grid impedance adaptation of the current controller is proposed. The design of the current controller is described and the adaptation strategy to prevent the excitation of the system resonance frequency during grid-impedance changes is introduced. The actual grid impedance is estimated by an extended Kalman filter (EKF) and a Luenberger observer allows to use the same number of voltage and current sensors as in conventional PI controllers. The proposed control method provides the possibility to tune the controller dynamics independently from the grid impedance. The theoretical analysis is validated with laboratory measurements.