热老化对抗电晕磁铁导线电气寿命的影响

T. Han, A. Caprara, G. Ciotti, A. Rumi, A. Cavallini
{"title":"热老化对抗电晕磁铁导线电气寿命的影响","authors":"T. Han, A. Caprara, G. Ciotti, A. Rumi, A. Cavallini","doi":"10.1109/eic47619.2020.9158680","DOIUrl":null,"url":null,"abstract":"Corona-resistant winding wires help to mitigate the impact of partial discharge activity in inverter-fed machines. Despite the fact they are on the market since about 20 years, it is still unclear how wires with different insulation systems should be compared. We propose a combined thermo-electrical procedure that might help to provide a more accurate ranking of the wires assuming that corona-resistant winding wires might help to prevent premature failure, but they will not be able to withstand partial discharge activity throughout the expected lifetime of the insulation (e.g. 20 years).","PeriodicalId":286019,"journal":{"name":"2020 IEEE Electrical Insulation Conference (EIC)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Impact Of Thermal Aging On The Electrical Endurance Of Corona-Resistant Magnet Wires\",\"authors\":\"T. Han, A. Caprara, G. Ciotti, A. Rumi, A. Cavallini\",\"doi\":\"10.1109/eic47619.2020.9158680\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Corona-resistant winding wires help to mitigate the impact of partial discharge activity in inverter-fed machines. Despite the fact they are on the market since about 20 years, it is still unclear how wires with different insulation systems should be compared. We propose a combined thermo-electrical procedure that might help to provide a more accurate ranking of the wires assuming that corona-resistant winding wires might help to prevent premature failure, but they will not be able to withstand partial discharge activity throughout the expected lifetime of the insulation (e.g. 20 years).\",\"PeriodicalId\":286019,\"journal\":{\"name\":\"2020 IEEE Electrical Insulation Conference (EIC)\",\"volume\":\"34 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE Electrical Insulation Conference (EIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/eic47619.2020.9158680\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Electrical Insulation Conference (EIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/eic47619.2020.9158680","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

抗电晕绕组线有助于减轻部分放电活动对逆变器供电机器的影响。尽管它们在市场上已经存在了大约20年,但人们仍然不清楚不同绝缘系统的电线应该如何进行比较。我们提出了一种结合热电程序,该程序可能有助于提供更准确的电线排名,假设抗电晕绕组电线可能有助于防止过早失效,但在绝缘的预期使用寿命(例如20年)内,它们将无法承受局部放电活动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Impact Of Thermal Aging On The Electrical Endurance Of Corona-Resistant Magnet Wires
Corona-resistant winding wires help to mitigate the impact of partial discharge activity in inverter-fed machines. Despite the fact they are on the market since about 20 years, it is still unclear how wires with different insulation systems should be compared. We propose a combined thermo-electrical procedure that might help to provide a more accurate ranking of the wires assuming that corona-resistant winding wires might help to prevent premature failure, but they will not be able to withstand partial discharge activity throughout the expected lifetime of the insulation (e.g. 20 years).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Onsite Testing and Diagnosis of Medium Voltage Resin Impregnated Paper (RIP) Insulated Buses by Using Very Low Frequency High Voltage Analysis and suggestion on the chromatographic detection of inverted oil immersed current transformer Detection of Partial Discharges Occurring in Propulsion Coils of Superconducting Maglev Systems from a Test Bogie Running at High Speed Using a Radio Interferometer System with a Vector-Antenna Life expectancy of high voltage bushings based on incipient failure detections: a practical approach Approaches to the forensic failure investigation of medium voltage polymeric cables
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1