一种用于吊扇的新型三相感应电机驱动器,提高了直流链路的利用率

A. Hota, V. Agarwal
{"title":"一种用于吊扇的新型三相感应电机驱动器,提高了直流链路的利用率","authors":"A. Hota, V. Agarwal","doi":"10.1109/SeFet48154.2021.9375648","DOIUrl":null,"url":null,"abstract":"A novel three phase induction motor drive for domestic ceiling fan application is proposed in this paper with improved dc-bus utilization. The proposed system is fed from a 50Hz single phase ac power source using a flyback-based power factor correction rectifier circuit, which results in 100Hz voltage ripple in the dc-link. The voltage ripple is considerable (nearly 10%) as a low value of capacitor is used to avoid high system cost. By using special carrier based space vector modulation (SVM) strategy the motor performance can be made immune to this voltage ripple but it limits the dc-bus utilization considerably. In this paper this problem is addressed by introducing an appropriate phase difference between the reference vector of the SVM and the dc-link voltage ripple. This phase difference is calculated by aligning the peaks of the modulation signal and the dc-link voltage ripple. It is shown that by doing so the dc-bus utilization can be increased. In the proposed case the dc-bus utilization is achieved to be 61% whereas any existing PWM strategy with ripple free dc-link voltage cannot have more than 57.7% dcbus utilization. Simulation studies are carried out in PLECS to support the theoretical claims. The experimental validation would be included in the final paper.","PeriodicalId":232560,"journal":{"name":"2021 International Conference on Sustainable Energy and Future Electric Transportation (SEFET)","volume":"119 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A Novel Three Phase Induction Motor Drive for Ceiling Fan Application with Improved Dc-link Utilization\",\"authors\":\"A. Hota, V. Agarwal\",\"doi\":\"10.1109/SeFet48154.2021.9375648\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A novel three phase induction motor drive for domestic ceiling fan application is proposed in this paper with improved dc-bus utilization. The proposed system is fed from a 50Hz single phase ac power source using a flyback-based power factor correction rectifier circuit, which results in 100Hz voltage ripple in the dc-link. The voltage ripple is considerable (nearly 10%) as a low value of capacitor is used to avoid high system cost. By using special carrier based space vector modulation (SVM) strategy the motor performance can be made immune to this voltage ripple but it limits the dc-bus utilization considerably. In this paper this problem is addressed by introducing an appropriate phase difference between the reference vector of the SVM and the dc-link voltage ripple. This phase difference is calculated by aligning the peaks of the modulation signal and the dc-link voltage ripple. It is shown that by doing so the dc-bus utilization can be increased. In the proposed case the dc-bus utilization is achieved to be 61% whereas any existing PWM strategy with ripple free dc-link voltage cannot have more than 57.7% dcbus utilization. Simulation studies are carried out in PLECS to support the theoretical claims. The experimental validation would be included in the final paper.\",\"PeriodicalId\":232560,\"journal\":{\"name\":\"2021 International Conference on Sustainable Energy and Future Electric Transportation (SEFET)\",\"volume\":\"119 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference on Sustainable Energy and Future Electric Transportation (SEFET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SeFet48154.2021.9375648\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Sustainable Energy and Future Electric Transportation (SEFET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SeFet48154.2021.9375648","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

提出了一种适用于家用吊扇的新型三相感应电动机驱动,提高了直流母线利用率。该系统采用基于反激的功率因数校正整流电路,从50Hz的单相交流电源供电,导致直流链路产生100Hz的电压纹波。电压纹波相当大(近10%),因为采用了低值的电容器以避免高系统成本。通过采用特殊的基于载波的空间矢量调制(SVM)策略,可以使电机性能不受电压纹波的影响,但这极大地限制了直流母线的利用率。本文通过在支持向量机的参考向量和直流电压纹波之间引入适当的相位差来解决这个问题。这个相位差是通过对准调制信号的峰值和直流链路电压纹波来计算的。结果表明,这样做可以提高直流母线的利用率。在这种情况下,直流总线利用率达到61%,而任何现有的无纹波直流链路电压的PWM策略都不能超过57.7%的直流总线利用率。仿真研究在PLECS中进行,以支持理论主张。实验验证将包含在最终论文中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Novel Three Phase Induction Motor Drive for Ceiling Fan Application with Improved Dc-link Utilization
A novel three phase induction motor drive for domestic ceiling fan application is proposed in this paper with improved dc-bus utilization. The proposed system is fed from a 50Hz single phase ac power source using a flyback-based power factor correction rectifier circuit, which results in 100Hz voltage ripple in the dc-link. The voltage ripple is considerable (nearly 10%) as a low value of capacitor is used to avoid high system cost. By using special carrier based space vector modulation (SVM) strategy the motor performance can be made immune to this voltage ripple but it limits the dc-bus utilization considerably. In this paper this problem is addressed by introducing an appropriate phase difference between the reference vector of the SVM and the dc-link voltage ripple. This phase difference is calculated by aligning the peaks of the modulation signal and the dc-link voltage ripple. It is shown that by doing so the dc-bus utilization can be increased. In the proposed case the dc-bus utilization is achieved to be 61% whereas any existing PWM strategy with ripple free dc-link voltage cannot have more than 57.7% dcbus utilization. Simulation studies are carried out in PLECS to support the theoretical claims. The experimental validation would be included in the final paper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Retrofication Of ICE Driven Auto-Rickshaw Seamless Transition between Grid-Connected and Islanded Operation Modes for Hybrid PV-BESS Combination used in Single-Phase, Critical Load Applications A Critical Study on Campus Energy Monitoring System and Role of IoT A Novel Switched-Capacitor Based Three-phase MultiLevel Inverter Fed induction motor for Agricultural Applications A New Single-Phase Five-Level Neutral Point Clamped Cascaded Multilevel Inverter for Minimization of Leakage Current in PV Systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1