{"title":"用于给药系统的大流量串联多腔压电微泵设计分析","authors":"E. D. Kurniawan, Widhya Budiawan, M. Chandra","doi":"10.1109/ICRAMET53537.2021.9650478","DOIUrl":null,"url":null,"abstract":"High flow rate of Lead Zirconate Titanate (PZT) actuated serial-connection multi-chamber piezoelectric micropumps (SCMCP micropumps) design for insulin therapy system was proposed. Four chambers in serial-connection micropumps with cantilever valves were introduced. The proposed design of micropumps will be made of biocompatible and non-toxic materials to ensure its safety. The specification of the proposed design of micropumps have a high flow rate of 10.7 mL/min and a backpressure of 34.3 kPa at driving voltage Vpp 36 V and 200 Hz operating frequency, respectively. Furthermore, the micropumps design was simulated by a simulations software tool to further study the pump model. The flow rate and static stress were investigated by software simulation.","PeriodicalId":269759,"journal":{"name":"2021 International Conference on Radar, Antenna, Microwave, Electronics, and Telecommunications (ICRAMET)","volume":"129 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Design Analysis of High Flow Rate Serial Connection Multi-Chamber Piezoelectric Micropump for Drug Delivery System\",\"authors\":\"E. D. Kurniawan, Widhya Budiawan, M. Chandra\",\"doi\":\"10.1109/ICRAMET53537.2021.9650478\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"High flow rate of Lead Zirconate Titanate (PZT) actuated serial-connection multi-chamber piezoelectric micropumps (SCMCP micropumps) design for insulin therapy system was proposed. Four chambers in serial-connection micropumps with cantilever valves were introduced. The proposed design of micropumps will be made of biocompatible and non-toxic materials to ensure its safety. The specification of the proposed design of micropumps have a high flow rate of 10.7 mL/min and a backpressure of 34.3 kPa at driving voltage Vpp 36 V and 200 Hz operating frequency, respectively. Furthermore, the micropumps design was simulated by a simulations software tool to further study the pump model. The flow rate and static stress were investigated by software simulation.\",\"PeriodicalId\":269759,\"journal\":{\"name\":\"2021 International Conference on Radar, Antenna, Microwave, Electronics, and Telecommunications (ICRAMET)\",\"volume\":\"129 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference on Radar, Antenna, Microwave, Electronics, and Telecommunications (ICRAMET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICRAMET53537.2021.9650478\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Radar, Antenna, Microwave, Electronics, and Telecommunications (ICRAMET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICRAMET53537.2021.9650478","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Design Analysis of High Flow Rate Serial Connection Multi-Chamber Piezoelectric Micropump for Drug Delivery System
High flow rate of Lead Zirconate Titanate (PZT) actuated serial-connection multi-chamber piezoelectric micropumps (SCMCP micropumps) design for insulin therapy system was proposed. Four chambers in serial-connection micropumps with cantilever valves were introduced. The proposed design of micropumps will be made of biocompatible and non-toxic materials to ensure its safety. The specification of the proposed design of micropumps have a high flow rate of 10.7 mL/min and a backpressure of 34.3 kPa at driving voltage Vpp 36 V and 200 Hz operating frequency, respectively. Furthermore, the micropumps design was simulated by a simulations software tool to further study the pump model. The flow rate and static stress were investigated by software simulation.