一种新型功率加权并联逆变器同步控制方法

W. Shuang, Ma Yundong, Wang Junqi, Jing XiaoLan
{"title":"一种新型功率加权并联逆变器同步控制方法","authors":"W. Shuang, Ma Yundong, Wang Junqi, Jing XiaoLan","doi":"10.1109/ICIEA.2010.5514880","DOIUrl":null,"url":null,"abstract":"For parallel inverters, the sinusoidal output ac voltages in the same-phase should be ensured. This paper presents a power weighted synchronous control method, which is suitable for parallel inverters of different power capabilities. The key concept of the proposed strategy is that the sinusoidal reference signal is decided by the common synchronous pulse signal, which is determined by the majority of the inverters, and the power weighting factor is taken into account. By doing so, the sinusoidal reference signal cannot be interrupted even though one of the modules is fault or dropout. Firstly, the operation principle is described by comparing the conventional method and the proposed method in this paper. Secondly, the hardware implementation is given. Then a detailed reliability failure analysis of synchronous regulation is presented, which shows that higher precision of the control system is obtained compared with the existing methods. At last, the experimental results prove that the control strategy can be well achieved by the designed circuit, and the synchronization of each module is realized.","PeriodicalId":234296,"journal":{"name":"2010 5th IEEE Conference on Industrial Electronics and Applications","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A novel power weighted synchronous control method for parallel inverters\",\"authors\":\"W. Shuang, Ma Yundong, Wang Junqi, Jing XiaoLan\",\"doi\":\"10.1109/ICIEA.2010.5514880\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For parallel inverters, the sinusoidal output ac voltages in the same-phase should be ensured. This paper presents a power weighted synchronous control method, which is suitable for parallel inverters of different power capabilities. The key concept of the proposed strategy is that the sinusoidal reference signal is decided by the common synchronous pulse signal, which is determined by the majority of the inverters, and the power weighting factor is taken into account. By doing so, the sinusoidal reference signal cannot be interrupted even though one of the modules is fault or dropout. Firstly, the operation principle is described by comparing the conventional method and the proposed method in this paper. Secondly, the hardware implementation is given. Then a detailed reliability failure analysis of synchronous regulation is presented, which shows that higher precision of the control system is obtained compared with the existing methods. At last, the experimental results prove that the control strategy can be well achieved by the designed circuit, and the synchronization of each module is realized.\",\"PeriodicalId\":234296,\"journal\":{\"name\":\"2010 5th IEEE Conference on Industrial Electronics and Applications\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-06-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 5th IEEE Conference on Industrial Electronics and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIEA.2010.5514880\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 5th IEEE Conference on Industrial Electronics and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIEA.2010.5514880","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

对于并联逆变器,应保证输出的正弦交流电压在同一相位。本文提出了一种功率加权同步控制方法,适用于不同功率容量的并联逆变器。提出的策略的关键概念是正弦参考信号由大多数逆变器确定的公共同步脉冲信号决定,并考虑功率加权因素。通过这样做,即使其中一个模块出现故障或丢失,正弦参考信号也不会中断。首先,通过对传统方法和本文提出的方法的比较,阐述了该方法的工作原理。其次,给出了硬件实现。然后对同步调节的可靠性失效进行了详细的分析,结果表明,与现有方法相比,该方法获得了更高的控制精度。最后,实验结果证明了所设计的电路能够很好地实现控制策略,并实现了各模块的同步。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A novel power weighted synchronous control method for parallel inverters
For parallel inverters, the sinusoidal output ac voltages in the same-phase should be ensured. This paper presents a power weighted synchronous control method, which is suitable for parallel inverters of different power capabilities. The key concept of the proposed strategy is that the sinusoidal reference signal is decided by the common synchronous pulse signal, which is determined by the majority of the inverters, and the power weighting factor is taken into account. By doing so, the sinusoidal reference signal cannot be interrupted even though one of the modules is fault or dropout. Firstly, the operation principle is described by comparing the conventional method and the proposed method in this paper. Secondly, the hardware implementation is given. Then a detailed reliability failure analysis of synchronous regulation is presented, which shows that higher precision of the control system is obtained compared with the existing methods. At last, the experimental results prove that the control strategy can be well achieved by the designed circuit, and the synchronization of each module is realized.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Forecasting next-day electricity prices with Hidden Markov Models Design of HTS Linear Induction Motor using GA and the Finite Element Method Hybrid recurrent fuzzy neural network control for permanent magnet synchronous motor applied in electric scooter Integrating human factors into nanotech sustainability assessment and communication An ID-based content extraction signatures without trusted party
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1