神经消融导管三维卷曲聚合物- si结构的研制

Ruiqi Lim, Weiguo Chen, D. Choong, M. R. Damalerio, Ming-Yuan Cheng
{"title":"神经消融导管三维卷曲聚合物- si结构的研制","authors":"Ruiqi Lim, Weiguo Chen, D. Choong, M. R. Damalerio, Ming-Yuan Cheng","doi":"10.1109/EPTC.2018.8654386","DOIUrl":null,"url":null,"abstract":"Renal denervation procedure had been emerging as a potential treatment for resistant hypertension condition. It is a minimally invasive procedure where radiofrequency (RF) energy is supplied to ablate and deactivate the renal artery nerve. The deactivation of the renal nerve helps to reduce and control the patient’s blood pressure level. In order to achieve multiple ablation sites per ablation cycle, multiple discrete RF electrodes and temperature sensors components are required for integration with ablation catheter. This is a tedious and time consuming process. To address this issue, this paper proposed a three dimensional roll-up polymer-silicon structure with an overall thickness of 110um for easy of assembly. This roll-up structure with a ‘belt’ slot feature will be used for assembling of MEMS based sensor chip into a single component. Bench-top mechanical testing to simulate the activation and de-activation of the catheter had been performed. The roll-up structure was able to achieve a smooth activation of 5° to 62° with a maximum length of 8mm (diameter) for 10 repeated cycles.","PeriodicalId":360239,"journal":{"name":"2018 IEEE 20th Electronics Packaging Technology Conference (EPTC)","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Development of Three Dimensional Roll-up Polymer-Si Structure for Nerve Ablation Catheter\",\"authors\":\"Ruiqi Lim, Weiguo Chen, D. Choong, M. R. Damalerio, Ming-Yuan Cheng\",\"doi\":\"10.1109/EPTC.2018.8654386\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Renal denervation procedure had been emerging as a potential treatment for resistant hypertension condition. It is a minimally invasive procedure where radiofrequency (RF) energy is supplied to ablate and deactivate the renal artery nerve. The deactivation of the renal nerve helps to reduce and control the patient’s blood pressure level. In order to achieve multiple ablation sites per ablation cycle, multiple discrete RF electrodes and temperature sensors components are required for integration with ablation catheter. This is a tedious and time consuming process. To address this issue, this paper proposed a three dimensional roll-up polymer-silicon structure with an overall thickness of 110um for easy of assembly. This roll-up structure with a ‘belt’ slot feature will be used for assembling of MEMS based sensor chip into a single component. Bench-top mechanical testing to simulate the activation and de-activation of the catheter had been performed. The roll-up structure was able to achieve a smooth activation of 5° to 62° with a maximum length of 8mm (diameter) for 10 repeated cycles.\",\"PeriodicalId\":360239,\"journal\":{\"name\":\"2018 IEEE 20th Electronics Packaging Technology Conference (EPTC)\",\"volume\":\"50 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE 20th Electronics Packaging Technology Conference (EPTC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPTC.2018.8654386\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE 20th Electronics Packaging Technology Conference (EPTC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPTC.2018.8654386","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

肾去神经手术已成为一种治疗顽固性高血压的潜在方法。这是一种微创手术,提供射频(RF)能量来消融和使肾动脉神经失活。肾神经的失活有助于降低和控制患者的血压水平。为了实现每个消融周期的多个消融点,需要多个离散的射频电极和温度传感器组件与消融导管集成。这是一个冗长而耗时的过程。为了解决这一问题,本文提出了一种总厚度为110um的三维卷卷式聚合物硅结构,便于组装。这种带有“带”槽特征的卷式结构将用于将基于MEMS的传感器芯片组装成单个组件。已经进行了模拟导管激活和停用的台式机械测试。卷起结构能够实现5°至62°的平滑激活,最大长度为8mm(直径),重复循环10次。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development of Three Dimensional Roll-up Polymer-Si Structure for Nerve Ablation Catheter
Renal denervation procedure had been emerging as a potential treatment for resistant hypertension condition. It is a minimally invasive procedure where radiofrequency (RF) energy is supplied to ablate and deactivate the renal artery nerve. The deactivation of the renal nerve helps to reduce and control the patient’s blood pressure level. In order to achieve multiple ablation sites per ablation cycle, multiple discrete RF electrodes and temperature sensors components are required for integration with ablation catheter. This is a tedious and time consuming process. To address this issue, this paper proposed a three dimensional roll-up polymer-silicon structure with an overall thickness of 110um for easy of assembly. This roll-up structure with a ‘belt’ slot feature will be used for assembling of MEMS based sensor chip into a single component. Bench-top mechanical testing to simulate the activation and de-activation of the catheter had been performed. The roll-up structure was able to achieve a smooth activation of 5° to 62° with a maximum length of 8mm (diameter) for 10 repeated cycles.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Package Integrity and Reliability Effects of Mold Compound Chemistry for Power Device Application Kirkendall Voids Improvement in Thin Small No Lead Package Implementation of High-Temperature Pressure Sensor Package and Characterization up to 500°C EPIC Via Last on SOI Wafer Integration Challenges Laser hybrid integration on silicon photonic integrated circuits with reflected grating
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1