油导向冷却条件下酯油变压器连续热过载性能研究

Jeyabalan Velandy, Ankita Garg, C. Narasimhan
{"title":"油导向冷却条件下酯油变压器连续热过载性能研究","authors":"Jeyabalan Velandy, Ankita Garg, C. Narasimhan","doi":"10.1109/PIICON49524.2020.9113026","DOIUrl":null,"url":null,"abstract":"The prediction of temperature distribution in ester oil (natural and synthetic ester oil) filled transformer due to different types of cooling modes are important for thermal designer in order to utilize the ester oil benefits of biodegradable, fire safety substations and continuous overloading capabilities with respect to mineral oil. It is still a technical challenge for ester oil to utilize in transformers since higher viscosity of ester oil will leads to reduce the heat transfer process mainly in convection. With the ester oil in a transformer, there will be reduction of convection fluid currents which leads to higher temperature in top temperature oil and winding temperature rise in ester oil filled transformers. In this paper, the effects of mineral oil and ester oil on top oil rise, winding rise and hot-spot temperature arising from their potentially different thermal properties are investigated using Thermal hydraulic network model (THNM) on 60/75/90MVA, 220/33kV transformer. The power losses are calculated from FEM based simulations and experimental data for thermal analysis using THNM model. The direct impact of oil flow rate and total pressure drop over the windings in oil directed (OD) cooling modes are analyzed under rated loading and 120% continuous overloading capabilities (108MVA) with respect to mineral oil.","PeriodicalId":422853,"journal":{"name":"2020 IEEE 9th Power India International Conference (PIICON)","volume":"108 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Continuous Thermal Overloading Capabilities of Ester Oil Transformers in Oil Directed Cooling Conditions\",\"authors\":\"Jeyabalan Velandy, Ankita Garg, C. Narasimhan\",\"doi\":\"10.1109/PIICON49524.2020.9113026\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The prediction of temperature distribution in ester oil (natural and synthetic ester oil) filled transformer due to different types of cooling modes are important for thermal designer in order to utilize the ester oil benefits of biodegradable, fire safety substations and continuous overloading capabilities with respect to mineral oil. It is still a technical challenge for ester oil to utilize in transformers since higher viscosity of ester oil will leads to reduce the heat transfer process mainly in convection. With the ester oil in a transformer, there will be reduction of convection fluid currents which leads to higher temperature in top temperature oil and winding temperature rise in ester oil filled transformers. In this paper, the effects of mineral oil and ester oil on top oil rise, winding rise and hot-spot temperature arising from their potentially different thermal properties are investigated using Thermal hydraulic network model (THNM) on 60/75/90MVA, 220/33kV transformer. The power losses are calculated from FEM based simulations and experimental data for thermal analysis using THNM model. The direct impact of oil flow rate and total pressure drop over the windings in oil directed (OD) cooling modes are analyzed under rated loading and 120% continuous overloading capabilities (108MVA) with respect to mineral oil.\",\"PeriodicalId\":422853,\"journal\":{\"name\":\"2020 IEEE 9th Power India International Conference (PIICON)\",\"volume\":\"108 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE 9th Power India International Conference (PIICON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PIICON49524.2020.9113026\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 9th Power India International Conference (PIICON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PIICON49524.2020.9113026","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

对于热设计人员来说,预测不同冷却方式下酯油(天然酯油和合成酯油)填充变压器的温度分布是非常重要的,以便利用酯油在生物可降解、防火安全变电站中的优势,以及相对于矿物油的连续过载能力。高粘度的酯油会导致以对流为主的换热过程减少,因此在变压器中应用酯油仍然是一个技术难题。变压器中加入酯油后,对流流体电流减小,导致顶温油温度升高,充酯油变压器绕组温度升高。在60/75/90MVA、220/33kV变压器上,采用热液网络模型(THNM)研究了矿物油和酯油对因其热性能不同而产生的顶油升、绕组升和热点温度的影响。基于有限元模拟和THNM模型热分析的实验数据计算了功率损耗。在额定负载和矿物油120%连续过载能力(108MVA)下,分析了油导向(OD)冷却模式下油流量和绕组上总压降的直接影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Continuous Thermal Overloading Capabilities of Ester Oil Transformers in Oil Directed Cooling Conditions
The prediction of temperature distribution in ester oil (natural and synthetic ester oil) filled transformer due to different types of cooling modes are important for thermal designer in order to utilize the ester oil benefits of biodegradable, fire safety substations and continuous overloading capabilities with respect to mineral oil. It is still a technical challenge for ester oil to utilize in transformers since higher viscosity of ester oil will leads to reduce the heat transfer process mainly in convection. With the ester oil in a transformer, there will be reduction of convection fluid currents which leads to higher temperature in top temperature oil and winding temperature rise in ester oil filled transformers. In this paper, the effects of mineral oil and ester oil on top oil rise, winding rise and hot-spot temperature arising from their potentially different thermal properties are investigated using Thermal hydraulic network model (THNM) on 60/75/90MVA, 220/33kV transformer. The power losses are calculated from FEM based simulations and experimental data for thermal analysis using THNM model. The direct impact of oil flow rate and total pressure drop over the windings in oil directed (OD) cooling modes are analyzed under rated loading and 120% continuous overloading capabilities (108MVA) with respect to mineral oil.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An Improved Grid Synchronization Method of Grid-Interactive Power Converter System During Distorted Grid Conditions Design and Implementation of Biquad Filter for Shunt Compensation under Normal and Distorted Grid Conditions High Voltage Gain DC-DC Non-Isolated Converter with Generalized Stages Irregular-shaped Particle Motion and Charge Transfer Mechanism in Transformer Oil under Varying Field Reduce, Recycle And Reuse First Ever Initiative By Any Haryana Govt. Power Utility And Its Outcomes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1