{"title":"在混浊介质中使用近红外光谱的宽带仪器","authors":"C. Mu, A. Daryoush","doi":"10.1109/LTIMC.2004.1370991","DOIUrl":null,"url":null,"abstract":"A custom designed broadband NIR spectroscopy system is reported. A high-speed high power optical transmitter is designed over the frequency range from 100 MHz up to 3 GHz. Phantom experiments are performed to extract optical parameters of a turbid media simulating a breast tissue. Both broadband and single-frequency extraction methods are used to extract optical parameters of the phantom model. The comparison shows that the achieved extraction accuracy of optical parameter (/spl mu//sub a/, /spl mu//sub z/) using broadband extraction method is better than the single frequency technique.","PeriodicalId":317707,"journal":{"name":"Proceedings of the Lightwave Technologies in Instrumentation and Measurement Conference, 2004.","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-12-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Broadband instrumentation for spectroscopy in turbid media using NIR\",\"authors\":\"C. Mu, A. Daryoush\",\"doi\":\"10.1109/LTIMC.2004.1370991\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A custom designed broadband NIR spectroscopy system is reported. A high-speed high power optical transmitter is designed over the frequency range from 100 MHz up to 3 GHz. Phantom experiments are performed to extract optical parameters of a turbid media simulating a breast tissue. Both broadband and single-frequency extraction methods are used to extract optical parameters of the phantom model. The comparison shows that the achieved extraction accuracy of optical parameter (/spl mu//sub a/, /spl mu//sub z/) using broadband extraction method is better than the single frequency technique.\",\"PeriodicalId\":317707,\"journal\":{\"name\":\"Proceedings of the Lightwave Technologies in Instrumentation and Measurement Conference, 2004.\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-12-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Lightwave Technologies in Instrumentation and Measurement Conference, 2004.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/LTIMC.2004.1370991\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Lightwave Technologies in Instrumentation and Measurement Conference, 2004.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/LTIMC.2004.1370991","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Broadband instrumentation for spectroscopy in turbid media using NIR
A custom designed broadband NIR spectroscopy system is reported. A high-speed high power optical transmitter is designed over the frequency range from 100 MHz up to 3 GHz. Phantom experiments are performed to extract optical parameters of a turbid media simulating a breast tissue. Both broadband and single-frequency extraction methods are used to extract optical parameters of the phantom model. The comparison shows that the achieved extraction accuracy of optical parameter (/spl mu//sub a/, /spl mu//sub z/) using broadband extraction method is better than the single frequency technique.