{"title":"利用直焊冷却系统(DiSAC)提高超高导热模块C4的可靠性","authors":"O. Yamada, Y. Sawada, M. Harada, T. Yokozuka, A. Yasukawa, H. Moriya, N. Saito, K. Kasai, T. Uda, T. Netsu, K. Koyano","doi":"10.1109/ECTC.2001.927969","DOIUrl":null,"url":null,"abstract":"In the HITACHI MP6000 (HDS Skyline Trinium TM), the bipolar-CMOS processor dissipates about 600 W, and the new direct solder-attached cooling (named DiSAC) method has been developed for use with it. In this cooling method, the HDM is supported by the 97Sn/Ag C4 (or CCB; controlled collapse bonding) bumps, which are affected by almost all the deformation that occurs in the power on/off cycle. Hence, the fatigue life of the C4 bumps is most important in the application of this cooling method. In this paper, the causes of C4 bump strain are analyzed by the finite element method, and several techniques for reducing strain are simulated. A new method of estimating the fatigue life of the C4 connections, pseudo-elastic plastic creep analysis (EPC), is developed in order to improve the accuracy of fatigue life calculations, and is used to evaluate the creep strain in a 3D model. Using EPC and experimental C4 power cycle damage data, a new strain-fatigue life curve is defined. Process defects in the direct solder attachment are found to markedly shorten the fatigue life of the C4 connections, and the effects are estimated. All the technological developments presented are implemented in the DiSAC model, and the improvement in reliability is verified by experiment.","PeriodicalId":340217,"journal":{"name":"2001 Proceedings. 51st Electronic Components and Technology Conference (Cat. No.01CH37220)","volume":"75 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Improvement of the reliability of the C4 for ultrahigh thermal conduction module with the direct solder-attached cooling system (DiSAC)\",\"authors\":\"O. Yamada, Y. Sawada, M. Harada, T. Yokozuka, A. Yasukawa, H. Moriya, N. Saito, K. Kasai, T. Uda, T. Netsu, K. Koyano\",\"doi\":\"10.1109/ECTC.2001.927969\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the HITACHI MP6000 (HDS Skyline Trinium TM), the bipolar-CMOS processor dissipates about 600 W, and the new direct solder-attached cooling (named DiSAC) method has been developed for use with it. In this cooling method, the HDM is supported by the 97Sn/Ag C4 (or CCB; controlled collapse bonding) bumps, which are affected by almost all the deformation that occurs in the power on/off cycle. Hence, the fatigue life of the C4 bumps is most important in the application of this cooling method. In this paper, the causes of C4 bump strain are analyzed by the finite element method, and several techniques for reducing strain are simulated. A new method of estimating the fatigue life of the C4 connections, pseudo-elastic plastic creep analysis (EPC), is developed in order to improve the accuracy of fatigue life calculations, and is used to evaluate the creep strain in a 3D model. Using EPC and experimental C4 power cycle damage data, a new strain-fatigue life curve is defined. Process defects in the direct solder attachment are found to markedly shorten the fatigue life of the C4 connections, and the effects are estimated. All the technological developments presented are implemented in the DiSAC model, and the improvement in reliability is verified by experiment.\",\"PeriodicalId\":340217,\"journal\":{\"name\":\"2001 Proceedings. 51st Electronic Components and Technology Conference (Cat. No.01CH37220)\",\"volume\":\"75 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-05-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2001 Proceedings. 51st Electronic Components and Technology Conference (Cat. No.01CH37220)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECTC.2001.927969\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 Proceedings. 51st Electronic Components and Technology Conference (Cat. No.01CH37220)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECTC.2001.927969","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

在日立MP6000 (HDS Skyline Trinium TM)中,双极cmos处理器的功耗约为600 W,并且已经开发了新的直接焊接冷却(称为DiSAC)方法。在这种冷却方法中,HDM由97Sn/Ag C4(或CCB;可控的坍塌键合)颠簸,这是几乎所有的变形,发生在电源开/关周期的影响。因此,在采用这种冷却方法时,C4凸起的疲劳寿命是最重要的。本文采用有限元方法分析了C4碰撞应变产生的原因,并对几种减小应变的方法进行了模拟。为了提高C4连接疲劳寿命计算的精度,提出了一种估算C4连接疲劳寿命的新方法——伪弹塑性蠕变分析(EPC),并将其用于三维模型的蠕变应变评估。利用EPC和C4功率循环损伤实验数据,定义了新的应变-疲劳寿命曲线。发现直接焊料连接的工艺缺陷会显著缩短C4连接的疲劳寿命,并对其影响进行了估计。提出的所有技术发展都在DiSAC模型中实现,并通过实验验证了可靠性的提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Improvement of the reliability of the C4 for ultrahigh thermal conduction module with the direct solder-attached cooling system (DiSAC)
In the HITACHI MP6000 (HDS Skyline Trinium TM), the bipolar-CMOS processor dissipates about 600 W, and the new direct solder-attached cooling (named DiSAC) method has been developed for use with it. In this cooling method, the HDM is supported by the 97Sn/Ag C4 (or CCB; controlled collapse bonding) bumps, which are affected by almost all the deformation that occurs in the power on/off cycle. Hence, the fatigue life of the C4 bumps is most important in the application of this cooling method. In this paper, the causes of C4 bump strain are analyzed by the finite element method, and several techniques for reducing strain are simulated. A new method of estimating the fatigue life of the C4 connections, pseudo-elastic plastic creep analysis (EPC), is developed in order to improve the accuracy of fatigue life calculations, and is used to evaluate the creep strain in a 3D model. Using EPC and experimental C4 power cycle damage data, a new strain-fatigue life curve is defined. Process defects in the direct solder attachment are found to markedly shorten the fatigue life of the C4 connections, and the effects are estimated. All the technological developments presented are implemented in the DiSAC model, and the improvement in reliability is verified by experiment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A quasi three-dimensional distributed electromagnetic model for complex power distribution networks Thermal fatigue properties of lead-free solders on Cu and NiP under bump metallurgies Microlens arrays with integrated thin film power monitors Intermetallic reactions between lead-free SnAgCu solder and Ni(P)/Au surface finish on PWBs Nondestructive detection of intermetallics in solder joints by high energy X-ray diffraction
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1