{"title":"高压电缆局部放电故障的统计分析","authors":"Yangchun Cheng, Li Zhao, Xu-tao Wu, H. Ni, Pei Ding, Xiuguang Li, Xiu Zhou","doi":"10.1109/eic47619.2020.9158684","DOIUrl":null,"url":null,"abstract":"High voltage XLPE cable has become the mainstream of power transmission equipment. At present, the application experience of cable condition diagnosis technology is insufficient, and there is still room for improvement in key issues such as technical limitations, application methods, detection cycle and evaluation criteria. Therefore, it is very important to get more accurate cable condition evaluation criteria by statistical analysis of cable faults. In this paper, the partial discharge fault of cable is analyzed. First of all, the guidelines and regulations of existing cables in China are studied, and the standards related to partial discharge and temperature in current cable condition evaluation are understood. Secondly, the typical cable fault cases are collected, the partial discharge data of the fault cable is recorded, and its distribution form is obtained. Finally, on the basis of the above research work, a calculation method of conditional fault probability of cable under given local discharge amplitude is proposed, which can reflect the severity of partial discharge fault of high voltage cable to a certain extent.","PeriodicalId":286019,"journal":{"name":"2020 IEEE Electrical Insulation Conference (EIC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Statistical Analysis of Partial Discharge Faults of HV Cables\",\"authors\":\"Yangchun Cheng, Li Zhao, Xu-tao Wu, H. Ni, Pei Ding, Xiuguang Li, Xiu Zhou\",\"doi\":\"10.1109/eic47619.2020.9158684\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"High voltage XLPE cable has become the mainstream of power transmission equipment. At present, the application experience of cable condition diagnosis technology is insufficient, and there is still room for improvement in key issues such as technical limitations, application methods, detection cycle and evaluation criteria. Therefore, it is very important to get more accurate cable condition evaluation criteria by statistical analysis of cable faults. In this paper, the partial discharge fault of cable is analyzed. First of all, the guidelines and regulations of existing cables in China are studied, and the standards related to partial discharge and temperature in current cable condition evaluation are understood. Secondly, the typical cable fault cases are collected, the partial discharge data of the fault cable is recorded, and its distribution form is obtained. Finally, on the basis of the above research work, a calculation method of conditional fault probability of cable under given local discharge amplitude is proposed, which can reflect the severity of partial discharge fault of high voltage cable to a certain extent.\",\"PeriodicalId\":286019,\"journal\":{\"name\":\"2020 IEEE Electrical Insulation Conference (EIC)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE Electrical Insulation Conference (EIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/eic47619.2020.9158684\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Electrical Insulation Conference (EIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/eic47619.2020.9158684","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

高压交联聚乙烯电缆已成为电力输送设备的主流。目前,电缆状态诊断技术的应用经验不足,在技术限制、应用方法、检测周期、评价标准等关键问题上仍有改进的空间。因此,通过对电缆故障的统计分析,得到更准确的电缆状态评价标准是十分重要的。本文对电缆局部放电故障进行了分析。首先,对国内现有电缆的导则和法规进行了研究,了解了现行电缆状态评定中局部放电和温度的相关标准。其次,收集典型电缆故障案例,记录故障电缆局部放电数据,得到其分布形式;最后,在上述研究工作的基础上,提出了给定局部放电幅度下电缆条件故障概率的计算方法,该方法能在一定程度上反映高压电缆局部放电故障的严重程度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Statistical Analysis of Partial Discharge Faults of HV Cables
High voltage XLPE cable has become the mainstream of power transmission equipment. At present, the application experience of cable condition diagnosis technology is insufficient, and there is still room for improvement in key issues such as technical limitations, application methods, detection cycle and evaluation criteria. Therefore, it is very important to get more accurate cable condition evaluation criteria by statistical analysis of cable faults. In this paper, the partial discharge fault of cable is analyzed. First of all, the guidelines and regulations of existing cables in China are studied, and the standards related to partial discharge and temperature in current cable condition evaluation are understood. Secondly, the typical cable fault cases are collected, the partial discharge data of the fault cable is recorded, and its distribution form is obtained. Finally, on the basis of the above research work, a calculation method of conditional fault probability of cable under given local discharge amplitude is proposed, which can reflect the severity of partial discharge fault of high voltage cable to a certain extent.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Onsite Testing and Diagnosis of Medium Voltage Resin Impregnated Paper (RIP) Insulated Buses by Using Very Low Frequency High Voltage Analysis and suggestion on the chromatographic detection of inverted oil immersed current transformer Detection of Partial Discharges Occurring in Propulsion Coils of Superconducting Maglev Systems from a Test Bogie Running at High Speed Using a Radio Interferometer System with a Vector-Antenna Life expectancy of high voltage bushings based on incipient failure detections: a practical approach Approaches to the forensic failure investigation of medium voltage polymeric cables
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1