L. Gallin-Martel, O. Rossetto, Y. Arnoud, B. Boyer, R. Delorme, R. Fabbro, M. Gallin-Martel, O. Guillaudin, A. Pélissier
{"title":"用于放射治疗在线剂量测量的高动态范围集成电荷-数字转换器的设计","authors":"L. Gallin-Martel, O. Rossetto, Y. Arnoud, B. Boyer, R. Delorme, R. Fabbro, M. Gallin-Martel, O. Guillaudin, A. Pélissier","doi":"10.1109/NSSMIC.2016.8069397","DOIUrl":null,"url":null,"abstract":"The Intensity Modulated Radiotherapy allows a more efficient dose delivery in the tumour leading to a reduction of the dose deposited in the nearby healthy organs. However, this technique requires additional resources to perform on line dosimetry and insure patient safety. A quasi transparent 2D transmission detector for monitoring the treatment X-ray beam has been developed. It includes a high performance embedded electronics relying on a Charge to Digital Converter designed in a CMOS 0.35 μm process. The Charge Balancing Integration technique coupled to an internal 6-bit Analog to Digital Converter allows high resolution and high dynamic range to be reached. This 16-channel, 16-bit converter exhibits a 6 fC LSB value, a nonlinearity better than 0.1 LSB and a RMS noise lower than 0.5 LSB.","PeriodicalId":184587,"journal":{"name":"2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)","volume":"152 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Design of a high dynamic range integrated charge to digital converter for online dosimetry in radiotherapy\",\"authors\":\"L. Gallin-Martel, O. Rossetto, Y. Arnoud, B. Boyer, R. Delorme, R. Fabbro, M. Gallin-Martel, O. Guillaudin, A. Pélissier\",\"doi\":\"10.1109/NSSMIC.2016.8069397\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Intensity Modulated Radiotherapy allows a more efficient dose delivery in the tumour leading to a reduction of the dose deposited in the nearby healthy organs. However, this technique requires additional resources to perform on line dosimetry and insure patient safety. A quasi transparent 2D transmission detector for monitoring the treatment X-ray beam has been developed. It includes a high performance embedded electronics relying on a Charge to Digital Converter designed in a CMOS 0.35 μm process. The Charge Balancing Integration technique coupled to an internal 6-bit Analog to Digital Converter allows high resolution and high dynamic range to be reached. This 16-channel, 16-bit converter exhibits a 6 fC LSB value, a nonlinearity better than 0.1 LSB and a RMS noise lower than 0.5 LSB.\",\"PeriodicalId\":184587,\"journal\":{\"name\":\"2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)\",\"volume\":\"152 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2016.8069397\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2016.8069397","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
摘要
强度调制放射治疗允许在肿瘤中更有效的剂量传递,从而减少沉积在附近健康器官中的剂量。然而,这项技术需要额外的资源来进行在线剂量测定并确保患者的安全。研制了一种用于监测治疗x射线束的准透明二维透射探测器。它包括一个高性能的嵌入式电子元件,依赖于以CMOS 0.35 μm工艺设计的电荷到数字转换器。电荷平衡集成技术与内部6位模数转换器相结合,可以达到高分辨率和高动态范围。该16通道16位转换器具有6 fC LSB值,非线性优于0.1 LSB, RMS噪声低于0.5 LSB。
Design of a high dynamic range integrated charge to digital converter for online dosimetry in radiotherapy
The Intensity Modulated Radiotherapy allows a more efficient dose delivery in the tumour leading to a reduction of the dose deposited in the nearby healthy organs. However, this technique requires additional resources to perform on line dosimetry and insure patient safety. A quasi transparent 2D transmission detector for monitoring the treatment X-ray beam has been developed. It includes a high performance embedded electronics relying on a Charge to Digital Converter designed in a CMOS 0.35 μm process. The Charge Balancing Integration technique coupled to an internal 6-bit Analog to Digital Converter allows high resolution and high dynamic range to be reached. This 16-channel, 16-bit converter exhibits a 6 fC LSB value, a nonlinearity better than 0.1 LSB and a RMS noise lower than 0.5 LSB.