一种基于模块化多电平矩阵变换器的变速驱动器功率损耗穿越控制策略

Efraín Ibaceta, M. Díaz, Matías Uriarte, F. Rojas, A. Letelier, R. Cárdenas
{"title":"一种基于模块化多电平矩阵变换器的变速驱动器功率损耗穿越控制策略","authors":"Efraín Ibaceta, M. Díaz, Matías Uriarte, F. Rojas, A. Letelier, R. Cárdenas","doi":"10.1109/ICAACCA51523.2021.9465236","DOIUrl":null,"url":null,"abstract":"Modern variable-speed drives must be able to deal with ride-through faults with dips of 70–90% to ensure the continuity of the process without the energy store station discharge and carry out significant effects to its performance. So, the existent contingencies to such case are tripping-method from grid, robust DC-Link with higher capacitors and additional power electronic hardware. Nevertheless, they comprehend a common drawback for being costly in the industry. Therefore, the Power Loss Ride Through behaviour on variable-speed drives is an important feature which is a worst-case where the system can suffer dips near to 99% on grid. Recently, Modular Multilevel Cascade Converters have been applied in Variable-Speed Drives applications due to their capability to operate at high-power rates and features such as enhanced fault-ride through capability during critical dip voltage (e.g., 99% of amplitude) in grid. Therefore, this paper presents a control strategy based on a transition mechanism between outer control loops on the nested control of a Modular Multilevel Matrix Converter drive with the aim to improve the Power Loss Ride-Through performance through keeping the energy store station uniform and stable. Simulation results obtained using PLECS software are presented to validate the effectiveness of the proposed control strategy.","PeriodicalId":328922,"journal":{"name":"2021 IEEE International Conference on Automation/XXIV Congress of the Chilean Association of Automatic Control (ICA-ACCA)","volume":"102 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A Power Loss Ride Through Control Strategy for Variable Speed Drives based on the Modular Multilevel Matrix Converter\",\"authors\":\"Efraín Ibaceta, M. Díaz, Matías Uriarte, F. Rojas, A. Letelier, R. Cárdenas\",\"doi\":\"10.1109/ICAACCA51523.2021.9465236\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Modern variable-speed drives must be able to deal with ride-through faults with dips of 70–90% to ensure the continuity of the process without the energy store station discharge and carry out significant effects to its performance. So, the existent contingencies to such case are tripping-method from grid, robust DC-Link with higher capacitors and additional power electronic hardware. Nevertheless, they comprehend a common drawback for being costly in the industry. Therefore, the Power Loss Ride Through behaviour on variable-speed drives is an important feature which is a worst-case where the system can suffer dips near to 99% on grid. Recently, Modular Multilevel Cascade Converters have been applied in Variable-Speed Drives applications due to their capability to operate at high-power rates and features such as enhanced fault-ride through capability during critical dip voltage (e.g., 99% of amplitude) in grid. Therefore, this paper presents a control strategy based on a transition mechanism between outer control loops on the nested control of a Modular Multilevel Matrix Converter drive with the aim to improve the Power Loss Ride-Through performance through keeping the energy store station uniform and stable. Simulation results obtained using PLECS software are presented to validate the effectiveness of the proposed control strategy.\",\"PeriodicalId\":328922,\"journal\":{\"name\":\"2021 IEEE International Conference on Automation/XXIV Congress of the Chilean Association of Automatic Control (ICA-ACCA)\",\"volume\":\"102 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-03-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE International Conference on Automation/XXIV Congress of the Chilean Association of Automatic Control (ICA-ACCA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICAACCA51523.2021.9465236\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE International Conference on Automation/XXIV Congress of the Chilean Association of Automatic Control (ICA-ACCA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICAACCA51523.2021.9465236","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

现代变速传动必须能够处理70-90%的行程故障,以保证过程的连续性,而不需要储能站放电,对其性能产生重大影响。因此,针对这种情况,现有的应急措施是脱离电网的跳闸方法、采用更高电容的鲁棒直流链路和额外的电力电子硬件。尽管如此,他们理解了一个共同的缺点,即在该行业中成本高昂。因此,变速驱动器上的功率损耗行驶行为是一个重要的特征,这是系统在电网上可能遭受接近99%的下降的最坏情况。最近,模块化多电平级联变换器已经应用于变速驱动应用,因为它们能够以高功率速率运行,并且具有在电网临界倾斜电压(例如,99%的幅度)期间增强的故障穿越能力等特点。因此,本文提出了一种基于外部控制回路之间过渡机制的模块化多电平矩阵变换器驱动嵌套控制策略,旨在通过保持储能站的均匀稳定来提高功率损耗穿越性能。利用PLECS软件进行了仿真,验证了所提控制策略的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Power Loss Ride Through Control Strategy for Variable Speed Drives based on the Modular Multilevel Matrix Converter
Modern variable-speed drives must be able to deal with ride-through faults with dips of 70–90% to ensure the continuity of the process without the energy store station discharge and carry out significant effects to its performance. So, the existent contingencies to such case are tripping-method from grid, robust DC-Link with higher capacitors and additional power electronic hardware. Nevertheless, they comprehend a common drawback for being costly in the industry. Therefore, the Power Loss Ride Through behaviour on variable-speed drives is an important feature which is a worst-case where the system can suffer dips near to 99% on grid. Recently, Modular Multilevel Cascade Converters have been applied in Variable-Speed Drives applications due to their capability to operate at high-power rates and features such as enhanced fault-ride through capability during critical dip voltage (e.g., 99% of amplitude) in grid. Therefore, this paper presents a control strategy based on a transition mechanism between outer control loops on the nested control of a Modular Multilevel Matrix Converter drive with the aim to improve the Power Loss Ride-Through performance through keeping the energy store station uniform and stable. Simulation results obtained using PLECS software are presented to validate the effectiveness of the proposed control strategy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Software Streamlining: Reducing Software to Essentials Parameter Estimation of Single Phase Transformer Using Jellyfish Search Optimizer Algorithm Radial Position Control of a Bearingless Machine with Active Disturbance Rejection Control Fuzzy an approach Technical Losses on Distribution Networks in the Presence of Distributed Energy Resources Efficiency Improvement of Solar Cells by Coating with Chlorophyll and Different Types of Oils
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1