{"title":"电网短路条件下双馈感应发电转子电流的计算","authors":"Zengbao Wang, A. Tang, Xu Zheng, Qiushi Xu","doi":"10.1109/ICGEA.2019.8880760","DOIUrl":null,"url":null,"abstract":"the doubly-fed wind power generator is more sensitive to the voltage of the machine falls, with the increasing of wind power installed capacity, power grid failure of doubly-fed wind power generator rotor current analysis and it is very important to evaluate accurately, relationship with doubly-fed wind power generator through the implementation of the low voltage and the analysis and calculation of fault electric parameters. Starting from the principle of doubly-fed induction generator, mathematical model is established, when grid short-circuit fault of its rotor galvanometer formula is derived, by time domain simulation results verify the validity of the expression and an example. The proposed expression using the voltage of the machine and the grid inverter control parameters can be calculated from short circuit at any time when the rotor current, has clear physical meaning and good practicability.","PeriodicalId":170713,"journal":{"name":"2019 IEEE 3rd International Conference on Green Energy and Applications (ICGEA)","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Calculation of Rotor Currents for Doubly-Fed Induction Generation under Short Circuits in Power Grids\",\"authors\":\"Zengbao Wang, A. Tang, Xu Zheng, Qiushi Xu\",\"doi\":\"10.1109/ICGEA.2019.8880760\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"the doubly-fed wind power generator is more sensitive to the voltage of the machine falls, with the increasing of wind power installed capacity, power grid failure of doubly-fed wind power generator rotor current analysis and it is very important to evaluate accurately, relationship with doubly-fed wind power generator through the implementation of the low voltage and the analysis and calculation of fault electric parameters. Starting from the principle of doubly-fed induction generator, mathematical model is established, when grid short-circuit fault of its rotor galvanometer formula is derived, by time domain simulation results verify the validity of the expression and an example. The proposed expression using the voltage of the machine and the grid inverter control parameters can be calculated from short circuit at any time when the rotor current, has clear physical meaning and good practicability.\",\"PeriodicalId\":170713,\"journal\":{\"name\":\"2019 IEEE 3rd International Conference on Green Energy and Applications (ICGEA)\",\"volume\":\"51 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE 3rd International Conference on Green Energy and Applications (ICGEA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICGEA.2019.8880760\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 3rd International Conference on Green Energy and Applications (ICGEA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICGEA.2019.8880760","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Calculation of Rotor Currents for Doubly-Fed Induction Generation under Short Circuits in Power Grids
the doubly-fed wind power generator is more sensitive to the voltage of the machine falls, with the increasing of wind power installed capacity, power grid failure of doubly-fed wind power generator rotor current analysis and it is very important to evaluate accurately, relationship with doubly-fed wind power generator through the implementation of the low voltage and the analysis and calculation of fault electric parameters. Starting from the principle of doubly-fed induction generator, mathematical model is established, when grid short-circuit fault of its rotor galvanometer formula is derived, by time domain simulation results verify the validity of the expression and an example. The proposed expression using the voltage of the machine and the grid inverter control parameters can be calculated from short circuit at any time when the rotor current, has clear physical meaning and good practicability.