{"title":"补筋混凝土加固锚固体系静力拉拔试验","authors":"P. K, R. K","doi":"10.36348/sjce.2022.v06i04.004","DOIUrl":null,"url":null,"abstract":"This paper presents experimental results of retrofitted anchorage system of structural concrete by using Post-Installation of Supplementary Anchorage (PISA) as a implicit strengthening measure and to improve the nonlinear performance of conventional anchorage system in hardened concrete. A total sixty specimens of M25 grade concrete (150x150x300mm) with two different size of rebar anchorage of 12mm, 16mm and five different configuration of conventional anchorage system was retrofitted by PISA technique is verified under direct tension pullout quasi static loads. The configuration of anchorage comprised by straight bar (A1), 90degree bend (A2), 180degree hook (A3), single head bar (A4) and double head bar (A5). The test parameters considered are bond strength, ductility, stiffness and bar-slip and test variables are configuration of anchorage, size of rebar and presence of supplementary steel. The obtained results validated by ANSYS modeling. This study concludes that a considerable improvement of nonlinear parameters such as ultimate load (3-8%), stiffness (4%-17%), ductility (16%-52%) and concrete contribution (6%-23%) by using PISA technique.","PeriodicalId":437137,"journal":{"name":"Saudi Journal of Civil Engineering","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Static Pullout Tests on Retrofitted Anchorage System in Concrete Using Supplementary Reinforcement\",\"authors\":\"P. K, R. K\",\"doi\":\"10.36348/sjce.2022.v06i04.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents experimental results of retrofitted anchorage system of structural concrete by using Post-Installation of Supplementary Anchorage (PISA) as a implicit strengthening measure and to improve the nonlinear performance of conventional anchorage system in hardened concrete. A total sixty specimens of M25 grade concrete (150x150x300mm) with two different size of rebar anchorage of 12mm, 16mm and five different configuration of conventional anchorage system was retrofitted by PISA technique is verified under direct tension pullout quasi static loads. The configuration of anchorage comprised by straight bar (A1), 90degree bend (A2), 180degree hook (A3), single head bar (A4) and double head bar (A5). The test parameters considered are bond strength, ductility, stiffness and bar-slip and test variables are configuration of anchorage, size of rebar and presence of supplementary steel. The obtained results validated by ANSYS modeling. This study concludes that a considerable improvement of nonlinear parameters such as ultimate load (3-8%), stiffness (4%-17%), ductility (16%-52%) and concrete contribution (6%-23%) by using PISA technique.\",\"PeriodicalId\":437137,\"journal\":{\"name\":\"Saudi Journal of Civil Engineering\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Saudi Journal of Civil Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.36348/sjce.2022.v06i04.004\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Saudi Journal of Civil Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36348/sjce.2022.v06i04.004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
摘要
本文介绍了采用后补锚固(Post-Installation of Supplementary anchor, PISA)作为一种隐式加固措施,改进加固混凝土结构锚固体系非线性性能的试验结果。采用PISA技术对M25级混凝土(150x150x300mm)共60个试件进行了直接拉拔准静荷载下的试验验证,试件采用12mm、16mm两种不同尺寸的钢筋锚固和5种不同配置的常规锚固体系。锚固结构由直杆(A1)、90度弯杆(A2)、180度挂钩(A3)、单头杆(A4)和双头杆(A5)组成。考虑的试验参数为粘结强度、延性、刚度和杆滑移,试验变量为锚固结构、钢筋尺寸和补筋的存在。通过ANSYS建模验证了所得结果。本研究得出结论,通过使用PISA技术,非线性参数如极限荷载(3-8%),刚度(4%-17%),延性(16%-52%)和混凝土贡献(6%-23%)有相当大的改善。
Static Pullout Tests on Retrofitted Anchorage System in Concrete Using Supplementary Reinforcement
This paper presents experimental results of retrofitted anchorage system of structural concrete by using Post-Installation of Supplementary Anchorage (PISA) as a implicit strengthening measure and to improve the nonlinear performance of conventional anchorage system in hardened concrete. A total sixty specimens of M25 grade concrete (150x150x300mm) with two different size of rebar anchorage of 12mm, 16mm and five different configuration of conventional anchorage system was retrofitted by PISA technique is verified under direct tension pullout quasi static loads. The configuration of anchorage comprised by straight bar (A1), 90degree bend (A2), 180degree hook (A3), single head bar (A4) and double head bar (A5). The test parameters considered are bond strength, ductility, stiffness and bar-slip and test variables are configuration of anchorage, size of rebar and presence of supplementary steel. The obtained results validated by ANSYS modeling. This study concludes that a considerable improvement of nonlinear parameters such as ultimate load (3-8%), stiffness (4%-17%), ductility (16%-52%) and concrete contribution (6%-23%) by using PISA technique.