补筋混凝土加固锚固体系静力拉拔试验

P. K, R. K
{"title":"补筋混凝土加固锚固体系静力拉拔试验","authors":"P. K, R. K","doi":"10.36348/sjce.2022.v06i04.004","DOIUrl":null,"url":null,"abstract":"This paper presents experimental results of retrofitted anchorage system of structural concrete by using Post-Installation of Supplementary Anchorage (PISA) as a implicit strengthening measure and to improve the nonlinear performance of conventional anchorage system in hardened concrete. A total sixty specimens of M25 grade concrete (150x150x300mm) with two different size of rebar anchorage of 12mm, 16mm and five different configuration of conventional anchorage system was retrofitted by PISA technique is verified under direct tension pullout quasi static loads. The configuration of anchorage comprised by straight bar (A1), 90degree bend (A2), 180degree hook (A3), single head bar (A4) and double head bar (A5). The test parameters considered are bond strength, ductility, stiffness and bar-slip and test variables are configuration of anchorage, size of rebar and presence of supplementary steel. The obtained results validated by ANSYS modeling. This study concludes that a considerable improvement of nonlinear parameters such as ultimate load (3-8%), stiffness (4%-17%), ductility (16%-52%) and concrete contribution (6%-23%) by using PISA technique.","PeriodicalId":437137,"journal":{"name":"Saudi Journal of Civil Engineering","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Static Pullout Tests on Retrofitted Anchorage System in Concrete Using Supplementary Reinforcement\",\"authors\":\"P. K, R. K\",\"doi\":\"10.36348/sjce.2022.v06i04.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents experimental results of retrofitted anchorage system of structural concrete by using Post-Installation of Supplementary Anchorage (PISA) as a implicit strengthening measure and to improve the nonlinear performance of conventional anchorage system in hardened concrete. A total sixty specimens of M25 grade concrete (150x150x300mm) with two different size of rebar anchorage of 12mm, 16mm and five different configuration of conventional anchorage system was retrofitted by PISA technique is verified under direct tension pullout quasi static loads. The configuration of anchorage comprised by straight bar (A1), 90degree bend (A2), 180degree hook (A3), single head bar (A4) and double head bar (A5). The test parameters considered are bond strength, ductility, stiffness and bar-slip and test variables are configuration of anchorage, size of rebar and presence of supplementary steel. The obtained results validated by ANSYS modeling. This study concludes that a considerable improvement of nonlinear parameters such as ultimate load (3-8%), stiffness (4%-17%), ductility (16%-52%) and concrete contribution (6%-23%) by using PISA technique.\",\"PeriodicalId\":437137,\"journal\":{\"name\":\"Saudi Journal of Civil Engineering\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Saudi Journal of Civil Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.36348/sjce.2022.v06i04.004\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Saudi Journal of Civil Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36348/sjce.2022.v06i04.004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文介绍了采用后补锚固(Post-Installation of Supplementary anchor, PISA)作为一种隐式加固措施,改进加固混凝土结构锚固体系非线性性能的试验结果。采用PISA技术对M25级混凝土(150x150x300mm)共60个试件进行了直接拉拔准静荷载下的试验验证,试件采用12mm、16mm两种不同尺寸的钢筋锚固和5种不同配置的常规锚固体系。锚固结构由直杆(A1)、90度弯杆(A2)、180度挂钩(A3)、单头杆(A4)和双头杆(A5)组成。考虑的试验参数为粘结强度、延性、刚度和杆滑移,试验变量为锚固结构、钢筋尺寸和补筋的存在。通过ANSYS建模验证了所得结果。本研究得出结论,通过使用PISA技术,非线性参数如极限荷载(3-8%),刚度(4%-17%),延性(16%-52%)和混凝土贡献(6%-23%)有相当大的改善。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Static Pullout Tests on Retrofitted Anchorage System in Concrete Using Supplementary Reinforcement
This paper presents experimental results of retrofitted anchorage system of structural concrete by using Post-Installation of Supplementary Anchorage (PISA) as a implicit strengthening measure and to improve the nonlinear performance of conventional anchorage system in hardened concrete. A total sixty specimens of M25 grade concrete (150x150x300mm) with two different size of rebar anchorage of 12mm, 16mm and five different configuration of conventional anchorage system was retrofitted by PISA technique is verified under direct tension pullout quasi static loads. The configuration of anchorage comprised by straight bar (A1), 90degree bend (A2), 180degree hook (A3), single head bar (A4) and double head bar (A5). The test parameters considered are bond strength, ductility, stiffness and bar-slip and test variables are configuration of anchorage, size of rebar and presence of supplementary steel. The obtained results validated by ANSYS modeling. This study concludes that a considerable improvement of nonlinear parameters such as ultimate load (3-8%), stiffness (4%-17%), ductility (16%-52%) and concrete contribution (6%-23%) by using PISA technique.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Laboratory Evaluation of the Hydraulic Conductivity as a Function of Changes in the Particle Size of a Cubitermes Sp Termite Mound Soil Treated with Lime Laboratory Evaluation of the Hydraulic Conductivity as a Function of Changes in the Particle Size of a Cubitermes Sp Termite Mound Soil Treated with Lime On-Grid Solar Traction System Experimental and Theoretical Shear Strength of Simply Supported Reinforced Concrete Beam Relationship between the Intrinsic Properties of Sands and the Parameters of Mathematical Particle Size Distribution Models for Predicting Geotechnical Quantities
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1