{"title":"H2−H∞控制设计的两步LMI方案","authors":"Tianyi He, G. Zhu, Xiang Chen","doi":"10.23919/ACC45564.2020.9148042","DOIUrl":null,"url":null,"abstract":"In this paper, a two-step H<inf>2</inf> − H<inf>∞</inf> control design scheme with guaranteed mixed H<inf>2</inf> and H<inf>∞</inf> performance is proposed. Different from the traditional H<inf>2</inf>/H<inf>∞</inf> control, the proposed method designs an H<inf>2</inf> controller for a nominal plant and then designs an extra Q operator to recover robustness in H<inf>∞</inf> sense for the closed-loop system. When the system uncertainty occurs, operator Q is triggered by a residual signal due to the error between the nominal model and the actual plants, and an extra control signal is generated by operator Q to compensate the nominal H<inf>2</inf> controller. It is noted that the proposed H<inf>2</inf> − H<inf>∞</inf> design scheme provides additional design freedom to reduce conservativeness, comparing with the traditional mixed H<inf>2</inf>/H<inf>∞</inf> control. The control design in the Linear Matrix Inequality (LMI) approach is applied to synthesize the H<inf>2</inf> − H<inf>∞</inf> controller. Simulation results of a numerical example are given to demonstrate that H<inf>2</inf> − H<inf>∞</inf> control design is able to compensate the nominal H<inf>2</inf> control and significantly improve system performance in the presence of system uncertainty. Moreover, two-step H<inf>2</inf> −H<inf>∞</inf> control renders better state responses than the traditional mixed H<inf>2</inf>/H<inf>∞</inf> control.","PeriodicalId":288450,"journal":{"name":"2020 American Control Conference (ACC)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"A Two-step LMI Scheme for H2 − H∞ Control Design\",\"authors\":\"Tianyi He, G. Zhu, Xiang Chen\",\"doi\":\"10.23919/ACC45564.2020.9148042\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a two-step H<inf>2</inf> − H<inf>∞</inf> control design scheme with guaranteed mixed H<inf>2</inf> and H<inf>∞</inf> performance is proposed. Different from the traditional H<inf>2</inf>/H<inf>∞</inf> control, the proposed method designs an H<inf>2</inf> controller for a nominal plant and then designs an extra Q operator to recover robustness in H<inf>∞</inf> sense for the closed-loop system. When the system uncertainty occurs, operator Q is triggered by a residual signal due to the error between the nominal model and the actual plants, and an extra control signal is generated by operator Q to compensate the nominal H<inf>2</inf> controller. It is noted that the proposed H<inf>2</inf> − H<inf>∞</inf> design scheme provides additional design freedom to reduce conservativeness, comparing with the traditional mixed H<inf>2</inf>/H<inf>∞</inf> control. The control design in the Linear Matrix Inequality (LMI) approach is applied to synthesize the H<inf>2</inf> − H<inf>∞</inf> controller. Simulation results of a numerical example are given to demonstrate that H<inf>2</inf> − H<inf>∞</inf> control design is able to compensate the nominal H<inf>2</inf> control and significantly improve system performance in the presence of system uncertainty. Moreover, two-step H<inf>2</inf> −H<inf>∞</inf> control renders better state responses than the traditional mixed H<inf>2</inf>/H<inf>∞</inf> control.\",\"PeriodicalId\":288450,\"journal\":{\"name\":\"2020 American Control Conference (ACC)\",\"volume\":\"49 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 American Control Conference (ACC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/ACC45564.2020.9148042\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 American Control Conference (ACC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/ACC45564.2020.9148042","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
In this paper, a two-step H2 − H∞ control design scheme with guaranteed mixed H2 and H∞ performance is proposed. Different from the traditional H2/H∞ control, the proposed method designs an H2 controller for a nominal plant and then designs an extra Q operator to recover robustness in H∞ sense for the closed-loop system. When the system uncertainty occurs, operator Q is triggered by a residual signal due to the error between the nominal model and the actual plants, and an extra control signal is generated by operator Q to compensate the nominal H2 controller. It is noted that the proposed H2 − H∞ design scheme provides additional design freedom to reduce conservativeness, comparing with the traditional mixed H2/H∞ control. The control design in the Linear Matrix Inequality (LMI) approach is applied to synthesize the H2 − H∞ controller. Simulation results of a numerical example are given to demonstrate that H2 − H∞ control design is able to compensate the nominal H2 control and significantly improve system performance in the presence of system uncertainty. Moreover, two-step H2 −H∞ control renders better state responses than the traditional mixed H2/H∞ control.