Lu Haiwei, Shi Kejian, Hui Shihan, Furu Wei, Yue Yongbin, Gu Taiyu
{"title":"配电网真空断路器转子结构对电机执行器运行特性的影响分析","authors":"Lu Haiwei, Shi Kejian, Hui Shihan, Furu Wei, Yue Yongbin, Gu Taiyu","doi":"10.1109/ACPEE53904.2022.9784101","DOIUrl":null,"url":null,"abstract":"Aiming at the problem of the permanent magnet loosening and falling off in the operation of the motor actuator used in vacuum circuit breaker, this paper puts forward three improvement schemes of driving motor rotor, which are rotor convex embedded type, linear embedded type and inverted V embedded type. Numerical simulation method is used to analyze the influence of rotor structure on the operating characteristics of vacuum circuit breaker motor actuator. The results show that the improved structure can effectively avoid the loosening and falling off of the permanent magnet due to mechanical impact, and the reliability of opening and closing operation of vacuum circuit breaker is improved.","PeriodicalId":118112,"journal":{"name":"2022 7th Asia Conference on Power and Electrical Engineering (ACPEE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Analysis of the influence of rotor structure on operating characteristics of motor actuator used in vacuum circuit breaker in distribution network\",\"authors\":\"Lu Haiwei, Shi Kejian, Hui Shihan, Furu Wei, Yue Yongbin, Gu Taiyu\",\"doi\":\"10.1109/ACPEE53904.2022.9784101\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aiming at the problem of the permanent magnet loosening and falling off in the operation of the motor actuator used in vacuum circuit breaker, this paper puts forward three improvement schemes of driving motor rotor, which are rotor convex embedded type, linear embedded type and inverted V embedded type. Numerical simulation method is used to analyze the influence of rotor structure on the operating characteristics of vacuum circuit breaker motor actuator. The results show that the improved structure can effectively avoid the loosening and falling off of the permanent magnet due to mechanical impact, and the reliability of opening and closing operation of vacuum circuit breaker is improved.\",\"PeriodicalId\":118112,\"journal\":{\"name\":\"2022 7th Asia Conference on Power and Electrical Engineering (ACPEE)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 7th Asia Conference on Power and Electrical Engineering (ACPEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ACPEE53904.2022.9784101\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 7th Asia Conference on Power and Electrical Engineering (ACPEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ACPEE53904.2022.9784101","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis of the influence of rotor structure on operating characteristics of motor actuator used in vacuum circuit breaker in distribution network
Aiming at the problem of the permanent magnet loosening and falling off in the operation of the motor actuator used in vacuum circuit breaker, this paper puts forward three improvement schemes of driving motor rotor, which are rotor convex embedded type, linear embedded type and inverted V embedded type. Numerical simulation method is used to analyze the influence of rotor structure on the operating characteristics of vacuum circuit breaker motor actuator. The results show that the improved structure can effectively avoid the loosening and falling off of the permanent magnet due to mechanical impact, and the reliability of opening and closing operation of vacuum circuit breaker is improved.