外部影响对树脂铸造中压互感器频率相关传递比的影响

R. Stiegler, Jan Meyer
{"title":"外部影响对树脂铸造中压互感器频率相关传递比的影响","authors":"R. Stiegler, Jan Meyer","doi":"10.1109/ICHQP53011.2022.9808776","DOIUrl":null,"url":null,"abstract":"Inductive voltage transformers are widely used in medium voltage networks to measure harmonic voltages. The accuracy of these voltage transformers at frequencies other than nominal frequency (50Hz/60Hz) is not yet defined by standards, but can have a significant impact on the overall accuracy of voltage harmonic measurements. Consequently, the accurate assessment of harmonic voltage levels, e.g. for verifying compliance with compatibility levels, planning levels or emission limits, requires knowledge about the frequency-dependent transfer characteristic of the used voltage transformers. This transfer characteristic of a voltage transformer is not constant, but depends on a complex set of influence factors, like temperature, burden, etc. Therefore, within the EMPIR project 19NRM05 IT4PQ, the effects of different external factors on the accuracy of inductive voltage transformers is systematically investigated. This paper shows the influence of selected external factors (temperature, burden and primary voltage) on the frequency-dependent transfer characteristic of resin cast medium voltage instrument transformers.","PeriodicalId":249133,"journal":{"name":"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Impact of external influences on the frequency dependent transfer ratio of resin cast MV voltage instrument transformers\",\"authors\":\"R. Stiegler, Jan Meyer\",\"doi\":\"10.1109/ICHQP53011.2022.9808776\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Inductive voltage transformers are widely used in medium voltage networks to measure harmonic voltages. The accuracy of these voltage transformers at frequencies other than nominal frequency (50Hz/60Hz) is not yet defined by standards, but can have a significant impact on the overall accuracy of voltage harmonic measurements. Consequently, the accurate assessment of harmonic voltage levels, e.g. for verifying compliance with compatibility levels, planning levels or emission limits, requires knowledge about the frequency-dependent transfer characteristic of the used voltage transformers. This transfer characteristic of a voltage transformer is not constant, but depends on a complex set of influence factors, like temperature, burden, etc. Therefore, within the EMPIR project 19NRM05 IT4PQ, the effects of different external factors on the accuracy of inductive voltage transformers is systematically investigated. This paper shows the influence of selected external factors (temperature, burden and primary voltage) on the frequency-dependent transfer characteristic of resin cast medium voltage instrument transformers.\",\"PeriodicalId\":249133,\"journal\":{\"name\":\"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHQP53011.2022.9808776\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP53011.2022.9808776","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

电感式电压互感器广泛应用于中压电网中谐波电压的测量。这些电压互感器在标称频率(50Hz/60Hz)以外的频率下的精度尚未由标准定义,但可能对电压谐波测量的整体精度产生重大影响。因此,谐波电压水平的准确评估,例如为了验证是否符合兼容性水平、规划水平或排放限值,需要了解所用电压互感器的频率相关传输特性。电压互感器的这种传递特性不是恒定的,而是取决于一系列复杂的影响因素,如温度、负荷等。因此,在EMPIR项目19NRM05 IT4PQ中,系统地研究了不同外部因素对电感电压互感器精度的影响。本文介绍了选定的外部因素(温度、负荷和一次电压)对树脂铸造中压互感器频率相关传递特性的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Impact of external influences on the frequency dependent transfer ratio of resin cast MV voltage instrument transformers
Inductive voltage transformers are widely used in medium voltage networks to measure harmonic voltages. The accuracy of these voltage transformers at frequencies other than nominal frequency (50Hz/60Hz) is not yet defined by standards, but can have a significant impact on the overall accuracy of voltage harmonic measurements. Consequently, the accurate assessment of harmonic voltage levels, e.g. for verifying compliance with compatibility levels, planning levels or emission limits, requires knowledge about the frequency-dependent transfer characteristic of the used voltage transformers. This transfer characteristic of a voltage transformer is not constant, but depends on a complex set of influence factors, like temperature, burden, etc. Therefore, within the EMPIR project 19NRM05 IT4PQ, the effects of different external factors on the accuracy of inductive voltage transformers is systematically investigated. This paper shows the influence of selected external factors (temperature, burden and primary voltage) on the frequency-dependent transfer characteristic of resin cast medium voltage instrument transformers.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Voltage-Current Ratio Difference Method: Recommended for IEEE Standard 1547 to Determine the Customer Harmonic Contribution Operation of a Distributed Generation Plant in a Power Supply System with Non-linear and Asymmetric Load Trend analysis for power quality parameters based on long-term measurement campaigns Power Quality Data Platform for Analysis and Location of Voltage Dips: a Preliminary Study Classification of Scalogram Signatures for Power Quality Disturbances Using Transfer Learning
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1