Y. Sortais, S. Bize, C. Nicolas, C. Mandache, G. Santarelli, A. Clairon, C. Salomon
{"title":"一个喷泉中的铷和铯:寻找精细结构常数时间变化的新工具","authors":"Y. Sortais, S. Bize, C. Nicolas, C. Mandache, G. Santarelli, A. Clairon, C. Salomon","doi":"10.1109/FREQ.2001.956154","DOIUrl":null,"url":null,"abstract":"We have built in experiment to perform a test of the stability of the fine structure constant /spl alpha/=e/sup 2///spl nabla/c. This test is based on high accuracy comparisons between atomic microwave frequency standards using different atomic species. We have first developed a /sup 87/Rb fountain with a relative accuracy of 2/spl times/10/sup -15/ that we compare with BNM-LPTF Cs fountains. This comparison leads to a test of the stability of the fine structure constant at the level of 8/spl times/10/sup -15/ yr/sup -1/. We are now developing a dual fountain that will operate with /sup 87/Rb and /sup 133/Cs simultaneously. Using this device, we expect to improve the accuracy of Rb and Cs fountains and bring the resolution of the test of the stability of /spl alpha/ in the 10/sup -16/ yr/sup -1/ range. The Cs part of this device is giving satisfactory preliminary results.","PeriodicalId":369101,"journal":{"name":"Proceedings of the 2001 IEEE International Frequncy Control Symposium and PDA Exhibition (Cat. No.01CH37218)","volume":"86 4","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Rubidium and cesium in one fountain: a new tool for the search of the time variation of the fine structure constant\",\"authors\":\"Y. Sortais, S. Bize, C. Nicolas, C. Mandache, G. Santarelli, A. Clairon, C. Salomon\",\"doi\":\"10.1109/FREQ.2001.956154\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We have built in experiment to perform a test of the stability of the fine structure constant /spl alpha/=e/sup 2///spl nabla/c. This test is based on high accuracy comparisons between atomic microwave frequency standards using different atomic species. We have first developed a /sup 87/Rb fountain with a relative accuracy of 2/spl times/10/sup -15/ that we compare with BNM-LPTF Cs fountains. This comparison leads to a test of the stability of the fine structure constant at the level of 8/spl times/10/sup -15/ yr/sup -1/. We are now developing a dual fountain that will operate with /sup 87/Rb and /sup 133/Cs simultaneously. Using this device, we expect to improve the accuracy of Rb and Cs fountains and bring the resolution of the test of the stability of /spl alpha/ in the 10/sup -16/ yr/sup -1/ range. The Cs part of this device is giving satisfactory preliminary results.\",\"PeriodicalId\":369101,\"journal\":{\"name\":\"Proceedings of the 2001 IEEE International Frequncy Control Symposium and PDA Exhibition (Cat. No.01CH37218)\",\"volume\":\"86 4\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-06-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 2001 IEEE International Frequncy Control Symposium and PDA Exhibition (Cat. No.01CH37218)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/FREQ.2001.956154\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2001 IEEE International Frequncy Control Symposium and PDA Exhibition (Cat. No.01CH37218)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FREQ.2001.956154","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Rubidium and cesium in one fountain: a new tool for the search of the time variation of the fine structure constant
We have built in experiment to perform a test of the stability of the fine structure constant /spl alpha/=e/sup 2///spl nabla/c. This test is based on high accuracy comparisons between atomic microwave frequency standards using different atomic species. We have first developed a /sup 87/Rb fountain with a relative accuracy of 2/spl times/10/sup -15/ that we compare with BNM-LPTF Cs fountains. This comparison leads to a test of the stability of the fine structure constant at the level of 8/spl times/10/sup -15/ yr/sup -1/. We are now developing a dual fountain that will operate with /sup 87/Rb and /sup 133/Cs simultaneously. Using this device, we expect to improve the accuracy of Rb and Cs fountains and bring the resolution of the test of the stability of /spl alpha/ in the 10/sup -16/ yr/sup -1/ range. The Cs part of this device is giving satisfactory preliminary results.