一种133.3 dB动态范围脉搏血氧仪前端,具有低噪声区域高效失调抵消电流DAC

Soungchul Park, Wooyoung Kim, Suhwan Kim, Jooyeol Rhee
{"title":"一种133.3 dB动态范围脉搏血氧仪前端,具有低噪声区域高效失调抵消电流DAC","authors":"Soungchul Park, Wooyoung Kim, Suhwan Kim, Jooyeol Rhee","doi":"10.1109/ICEIC57457.2023.10049972","DOIUrl":null,"url":null,"abstract":"This paper introduces a pulse oximeter front-end with low-noise area-efficient offset cancellation current digital-to-analog converter (DAC). The proposed offset cancellation current DAC is implemented to cancel the input DC current to improve the effective dynamic range (DR). The current DAC is designed to have low-noise and area-efficient characteristics by applying the dynamic element matching technique and reducing the number of idle current mirror transistors. It can generate a current of up to 256 μA. Due to the offset cancellation of the current DAC, the proposed pulse oximeter has a signal-to-noise ratio of 77.4 dB and an effective DR of 133.3 dB. The pulse oximeter front-end is designed in 0.13 μm CMOS and consumes 307.1 μW from a 1.65 V supply. The figure-of-merit is 0.81 pJ/Sample.","PeriodicalId":373752,"journal":{"name":"2023 International Conference on Electronics, Information, and Communication (ICEIC)","volume":"1473 ","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A 133.3 dB Dynamic Range Pulse Oximeter Front-End with Low-Noise Area-Efficient Offset Cancellation Current DAC\",\"authors\":\"Soungchul Park, Wooyoung Kim, Suhwan Kim, Jooyeol Rhee\",\"doi\":\"10.1109/ICEIC57457.2023.10049972\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper introduces a pulse oximeter front-end with low-noise area-efficient offset cancellation current digital-to-analog converter (DAC). The proposed offset cancellation current DAC is implemented to cancel the input DC current to improve the effective dynamic range (DR). The current DAC is designed to have low-noise and area-efficient characteristics by applying the dynamic element matching technique and reducing the number of idle current mirror transistors. It can generate a current of up to 256 μA. Due to the offset cancellation of the current DAC, the proposed pulse oximeter has a signal-to-noise ratio of 77.4 dB and an effective DR of 133.3 dB. The pulse oximeter front-end is designed in 0.13 μm CMOS and consumes 307.1 μW from a 1.65 V supply. The figure-of-merit is 0.81 pJ/Sample.\",\"PeriodicalId\":373752,\"journal\":{\"name\":\"2023 International Conference on Electronics, Information, and Communication (ICEIC)\",\"volume\":\"1473 \",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 International Conference on Electronics, Information, and Communication (ICEIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEIC57457.2023.10049972\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 International Conference on Electronics, Information, and Communication (ICEIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEIC57457.2023.10049972","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了一种采用低噪声区域高效失调抵消电流数模转换器(DAC)的脉搏血氧仪前端。提出的失调抵消电流DAC是为了抵消输入直流电流以提高有效动态范围(DR)。采用动态元件匹配技术和减少空闲电流镜像晶体管的数量,设计出低噪声和面积效率高的电流DAC。它可以产生高达256 μA的电流。由于当前DAC的偏移抵消,所提出的脉搏血氧仪的信噪比为77.4 dB,有效DR为133.3 dB。脉搏血氧仪前端采用0.13 μm CMOS,功耗为307.1 μW,电源为1.65 V。品质因数为0.81 pJ/样品。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A 133.3 dB Dynamic Range Pulse Oximeter Front-End with Low-Noise Area-Efficient Offset Cancellation Current DAC
This paper introduces a pulse oximeter front-end with low-noise area-efficient offset cancellation current digital-to-analog converter (DAC). The proposed offset cancellation current DAC is implemented to cancel the input DC current to improve the effective dynamic range (DR). The current DAC is designed to have low-noise and area-efficient characteristics by applying the dynamic element matching technique and reducing the number of idle current mirror transistors. It can generate a current of up to 256 μA. Due to the offset cancellation of the current DAC, the proposed pulse oximeter has a signal-to-noise ratio of 77.4 dB and an effective DR of 133.3 dB. The pulse oximeter front-end is designed in 0.13 μm CMOS and consumes 307.1 μW from a 1.65 V supply. The figure-of-merit is 0.81 pJ/Sample.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
DWT+DWT: Deep Learning Domain Generalization Techniques Using Discrete Wavelet Transform with Deep Whitening Transform Fast Virtual Keyboard Typing Using Vowel Hand Gesture Recognition A Study on Edge Computing-Based Microservices Architecture Supporting IoT Device Management and Artificial Intelligence Inference Efficient Pavement Crack Detection in Drone Images using Deep Neural Networks High Performance 3.3KV 4H-SiC MOSFET with a Floating Island and Hetero Junction Diode
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1