{"title":"大尺度真实心室模型中节律性兴奋的模拟","authors":"G. Huiskamp","doi":"10.1109/IEMBS.1993.978816","DOIUrl":null,"url":null,"abstract":"Simulations of paced ventricular excitation using a model based on Beeler/Reuter ion dynamics have been performed. The resulting activation sequence is compared to one computed from ECG's measured on a patient undergoing cardiac pacing at the same stimulus location. Results show that in spite of the isotropic, homogeneous structure of the model major characteristics of the activation sequences are similar. In addition, ECG waveforms in the extremity leads computed from the simulated seqlience are similar to the ones measured on the patient.","PeriodicalId":408657,"journal":{"name":"Proceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Societ","volume":"1997 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Simulation of paced excitation in a large scale realistic ventricular model\",\"authors\":\"G. Huiskamp\",\"doi\":\"10.1109/IEMBS.1993.978816\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Simulations of paced ventricular excitation using a model based on Beeler/Reuter ion dynamics have been performed. The resulting activation sequence is compared to one computed from ECG's measured on a patient undergoing cardiac pacing at the same stimulus location. Results show that in spite of the isotropic, homogeneous structure of the model major characteristics of the activation sequences are similar. In addition, ECG waveforms in the extremity leads computed from the simulated seqlience are similar to the ones measured on the patient.\",\"PeriodicalId\":408657,\"journal\":{\"name\":\"Proceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Societ\",\"volume\":\"1997 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-10-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Societ\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMBS.1993.978816\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Societ","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1993.978816","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Simulation of paced excitation in a large scale realistic ventricular model
Simulations of paced ventricular excitation using a model based on Beeler/Reuter ion dynamics have been performed. The resulting activation sequence is compared to one computed from ECG's measured on a patient undergoing cardiac pacing at the same stimulus location. Results show that in spite of the isotropic, homogeneous structure of the model major characteristics of the activation sequences are similar. In addition, ECG waveforms in the extremity leads computed from the simulated seqlience are similar to the ones measured on the patient.