开放式定子绕组双逆变器馈电五相交流驱动器的共模电压消除方案

P. Rajeevan, H. Abu-Rub, A. Iqbal, K. Gopakumar
{"title":"开放式定子绕组双逆变器馈电五相交流驱动器的共模电压消除方案","authors":"P. Rajeevan, H. Abu-Rub, A. Iqbal, K. Gopakumar","doi":"10.1109/ICIT.2013.6505927","DOIUrl":null,"url":null,"abstract":"This paper proposes a PWM scheme for common-mode voltage elimination of a five-phase inverter fed AC drive with open-end stator windings. Alternating common mode voltages are eliminated from the inverter poles as well as phase voltages thereby mitigating all the problems due to common mode voltages usually encountered in PWM inverter-fed drives, considered to be one of the main reasons for mechanical failures of the motor. In addition, the elimination of common mode voltages facilitates the use of single DC source for feeding both ends of the windings through two five-phase, two-level inverters. A carrier based technique without involving any dwell time calculations or sector identification is proposed for implementation of the PWM scheme. The proposed PWM scheme is validated by extensive simulation on a Matlab/Simulink platform and then verified experimentally on a laboratory prototype.","PeriodicalId":192784,"journal":{"name":"2013 IEEE International Conference on Industrial Technology (ICIT)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":"{\"title\":\"Common mode voltage elimination scheme for dual-inverter fed five phase AC drives with open-end stator windings\",\"authors\":\"P. Rajeevan, H. Abu-Rub, A. Iqbal, K. Gopakumar\",\"doi\":\"10.1109/ICIT.2013.6505927\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a PWM scheme for common-mode voltage elimination of a five-phase inverter fed AC drive with open-end stator windings. Alternating common mode voltages are eliminated from the inverter poles as well as phase voltages thereby mitigating all the problems due to common mode voltages usually encountered in PWM inverter-fed drives, considered to be one of the main reasons for mechanical failures of the motor. In addition, the elimination of common mode voltages facilitates the use of single DC source for feeding both ends of the windings through two five-phase, two-level inverters. A carrier based technique without involving any dwell time calculations or sector identification is proposed for implementation of the PWM scheme. The proposed PWM scheme is validated by extensive simulation on a Matlab/Simulink platform and then verified experimentally on a laboratory prototype.\",\"PeriodicalId\":192784,\"journal\":{\"name\":\"2013 IEEE International Conference on Industrial Technology (ICIT)\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-04-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE International Conference on Industrial Technology (ICIT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIT.2013.6505927\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE International Conference on Industrial Technology (ICIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIT.2013.6505927","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

摘要

本文提出了一种采用开端定子绕组的五相变频器共模电压消除的PWM方案。交流共模电压从逆变器极点以及相位电压中消除,从而减轻了由于PWM逆变器驱动中通常遇到的共模电压而引起的所有问题,这被认为是电机机械故障的主要原因之一。此外,消除共模电压有助于使用单个直流电源通过两个五相双电平逆变器为绕组的两端供电。提出了一种基于载波的技术,不涉及任何停留时间计算或扇区识别,用于实现PWM方案。在Matlab/Simulink平台上对所提出的PWM方案进行了广泛的仿真验证,然后在实验室样机上进行了实验验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Common mode voltage elimination scheme for dual-inverter fed five phase AC drives with open-end stator windings
This paper proposes a PWM scheme for common-mode voltage elimination of a five-phase inverter fed AC drive with open-end stator windings. Alternating common mode voltages are eliminated from the inverter poles as well as phase voltages thereby mitigating all the problems due to common mode voltages usually encountered in PWM inverter-fed drives, considered to be one of the main reasons for mechanical failures of the motor. In addition, the elimination of common mode voltages facilitates the use of single DC source for feeding both ends of the windings through two five-phase, two-level inverters. A carrier based technique without involving any dwell time calculations or sector identification is proposed for implementation of the PWM scheme. The proposed PWM scheme is validated by extensive simulation on a Matlab/Simulink platform and then verified experimentally on a laboratory prototype.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Low cost circular couplers for bi-directional IPT systems Performance evaluation of variable rates raptor codes in mobile WiMAX Improved non-ideality compensation for the V/f controlled permanent magnet synchronous motor Overview of helical foil winding design for planar magnetic components Tactile proximity sensors for robotic applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1