Ariba Siddiqui, Kamalesh Tripathy, M. Bhattacharjee
{"title":"柔性换能器在生物医学植入物中的超声功率传输","authors":"Ariba Siddiqui, Kamalesh Tripathy, M. Bhattacharjee","doi":"10.1109/fleps53764.2022.9781494","DOIUrl":null,"url":null,"abstract":"Biomedical implants, considered as a remarkable breakthrough in the field of medical science has been evolving gradually over the past few decades. However, charging them through batteries is a major issue due to their short lifespan and bulky nature. Therefore, to eliminate the use of batteries Ultrasonic Power Transmission (UPT) technology is perceived as the ideal technique for charging implants. This paper proposes an optimum computational model of the UPT system employing PVDF (polyvinylidene fluoride) based transducer. It was simulated at an optimum frequency of 900 kHz that resulted in an acoustic pressure of 218 Pa at the transmitting end. At a depth of 3 cm, the simulated model is able to generate a maximum output voltage of 0.13 volts and an energy density of 4.21 µJ/m3 at the receiver output. The proposed UPT model on a PVDF (polyvinylidene fluoride) substrate facilitates higher flexibility, superior biocompatibility with light-weight structure and stable mechanical property.","PeriodicalId":221424,"journal":{"name":"2022 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Ultrasonic Power Transfer in Biomedical Implants using Flexible Transducer\",\"authors\":\"Ariba Siddiqui, Kamalesh Tripathy, M. Bhattacharjee\",\"doi\":\"10.1109/fleps53764.2022.9781494\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Biomedical implants, considered as a remarkable breakthrough in the field of medical science has been evolving gradually over the past few decades. However, charging them through batteries is a major issue due to their short lifespan and bulky nature. Therefore, to eliminate the use of batteries Ultrasonic Power Transmission (UPT) technology is perceived as the ideal technique for charging implants. This paper proposes an optimum computational model of the UPT system employing PVDF (polyvinylidene fluoride) based transducer. It was simulated at an optimum frequency of 900 kHz that resulted in an acoustic pressure of 218 Pa at the transmitting end. At a depth of 3 cm, the simulated model is able to generate a maximum output voltage of 0.13 volts and an energy density of 4.21 µJ/m3 at the receiver output. The proposed UPT model on a PVDF (polyvinylidene fluoride) substrate facilitates higher flexibility, superior biocompatibility with light-weight structure and stable mechanical property.\",\"PeriodicalId\":221424,\"journal\":{\"name\":\"2022 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS)\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-07-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/fleps53764.2022.9781494\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/fleps53764.2022.9781494","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Ultrasonic Power Transfer in Biomedical Implants using Flexible Transducer
Biomedical implants, considered as a remarkable breakthrough in the field of medical science has been evolving gradually over the past few decades. However, charging them through batteries is a major issue due to their short lifespan and bulky nature. Therefore, to eliminate the use of batteries Ultrasonic Power Transmission (UPT) technology is perceived as the ideal technique for charging implants. This paper proposes an optimum computational model of the UPT system employing PVDF (polyvinylidene fluoride) based transducer. It was simulated at an optimum frequency of 900 kHz that resulted in an acoustic pressure of 218 Pa at the transmitting end. At a depth of 3 cm, the simulated model is able to generate a maximum output voltage of 0.13 volts and an energy density of 4.21 µJ/m3 at the receiver output. The proposed UPT model on a PVDF (polyvinylidene fluoride) substrate facilitates higher flexibility, superior biocompatibility with light-weight structure and stable mechanical property.