越多越好——在进行单囊泡表型分析时确定最佳范围

M. Gómez-Serrano, C. Preußer, Kathrin Stelter, E. Pogge von Strandmann
{"title":"越多越好——在进行单囊泡表型分析时确定最佳范围","authors":"M. Gómez-Serrano, C. Preußer, Kathrin Stelter, E. Pogge von Strandmann","doi":"10.47184/tev.2021.01.03","DOIUrl":null,"url":null,"abstract":"The characterization of extracellular vesicles (EVs) has evolved rapidly in recent years due to advances in straightforward technologies. Based on these more sensitive methods, it is now possible to describe EV populations in their entirety more precisely. However, these applications require an equivalently delicate experiment design and optimization steps to draw valid conclusions in the end. One of these methods is represented by the highly sensitive nanoflow cytometry (nFCM), by which particles can be analyzed not only on their size (< 40 nm) and concentration but also concerning surface markers. In this work, we addressed some of the potential caveats of this method, especially when characterizing particles with fluorescently labelled antibodies. In particular, we show, when using low particle concentrations, which are inevitably encountered when working with EVs, the characterization of surface markers is prone to significantly varying. We hypothesized that these technical limitations could respond to the stickiness of EVs and should be properly counteracted. As a reference, we strongly recommend performing particle number-based comparisons with at least 109 particles as staining input in nFCM analyses. Moreover, we provided representative particle-number based immunoblotting results, underlying the significance of this parameter as a normalizer in future EV research.","PeriodicalId":377329,"journal":{"name":"On the composition and therapeutic usage of extracellular vesicles","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The more the better – determining the optimal range when performing single-vesicle phenotyping\",\"authors\":\"M. Gómez-Serrano, C. Preußer, Kathrin Stelter, E. Pogge von Strandmann\",\"doi\":\"10.47184/tev.2021.01.03\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The characterization of extracellular vesicles (EVs) has evolved rapidly in recent years due to advances in straightforward technologies. Based on these more sensitive methods, it is now possible to describe EV populations in their entirety more precisely. However, these applications require an equivalently delicate experiment design and optimization steps to draw valid conclusions in the end. One of these methods is represented by the highly sensitive nanoflow cytometry (nFCM), by which particles can be analyzed not only on their size (< 40 nm) and concentration but also concerning surface markers. In this work, we addressed some of the potential caveats of this method, especially when characterizing particles with fluorescently labelled antibodies. In particular, we show, when using low particle concentrations, which are inevitably encountered when working with EVs, the characterization of surface markers is prone to significantly varying. We hypothesized that these technical limitations could respond to the stickiness of EVs and should be properly counteracted. As a reference, we strongly recommend performing particle number-based comparisons with at least 109 particles as staining input in nFCM analyses. Moreover, we provided representative particle-number based immunoblotting results, underlying the significance of this parameter as a normalizer in future EV research.\",\"PeriodicalId\":377329,\"journal\":{\"name\":\"On the composition and therapeutic usage of extracellular vesicles\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"On the composition and therapeutic usage of extracellular vesicles\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.47184/tev.2021.01.03\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"On the composition and therapeutic usage of extracellular vesicles","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47184/tev.2021.01.03","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

近年来,由于直接技术的进步,细胞外囊泡(ev)的表征发展迅速。基于这些更灵敏的方法,现在可以更精确地描述EV种群的整体。然而,这些应用需要同样精细的实验设计和优化步骤,最终得出有效的结论。其中一种方法以高灵敏度的纳米流式细胞术(nFCM)为代表,它不仅可以分析颗粒的大小(< 40 nm)和浓度,还可以分析表面标记物。在这项工作中,我们解决了这种方法的一些潜在的警告,特别是在用荧光标记抗体表征颗粒时。特别是,我们发现,当使用低颗粒浓度时(在使用电动汽车时不可避免地会遇到这种情况),表面标记物的表征容易发生显著变化。我们假设,这些技术限制可能会对电动汽车的粘性做出反应,应该适当地加以抵消。作为参考,我们强烈建议在nFCM分析中使用至少109个颗粒作为染色输入,进行基于颗粒数的比较。此外,我们提供了具有代表性的基于颗粒数的免疫印迹结果,表明该参数在未来EV研究中作为归一化因子的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The more the better – determining the optimal range when performing single-vesicle phenotyping
The characterization of extracellular vesicles (EVs) has evolved rapidly in recent years due to advances in straightforward technologies. Based on these more sensitive methods, it is now possible to describe EV populations in their entirety more precisely. However, these applications require an equivalently delicate experiment design and optimization steps to draw valid conclusions in the end. One of these methods is represented by the highly sensitive nanoflow cytometry (nFCM), by which particles can be analyzed not only on their size (< 40 nm) and concentration but also concerning surface markers. In this work, we addressed some of the potential caveats of this method, especially when characterizing particles with fluorescently labelled antibodies. In particular, we show, when using low particle concentrations, which are inevitably encountered when working with EVs, the characterization of surface markers is prone to significantly varying. We hypothesized that these technical limitations could respond to the stickiness of EVs and should be properly counteracted. As a reference, we strongly recommend performing particle number-based comparisons with at least 109 particles as staining input in nFCM analyses. Moreover, we provided representative particle-number based immunoblotting results, underlying the significance of this parameter as a normalizer in future EV research.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
RNAs and extracellular vesicles - Keeping up the appearances The more the better – determining the optimal range when performing single-vesicle phenotyping Establishment of a DFG-funded research group on the topic of plant-microbe communication through extracellular RNA Extracellular vesicle therapeutics: the issue of one size fits all
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1