高压套管的早期失效分析

Luciano Enciso, R. Álvarez, José L. Martínez, P. Arce, M. Galliani, Pablo Rodriguez, Emilo Calo
{"title":"高压套管的早期失效分析","authors":"Luciano Enciso, R. Álvarez, José L. Martínez, P. Arce, M. Galliani, Pablo Rodriguez, Emilo Calo","doi":"10.1109/eic47619.2020.9158713","DOIUrl":null,"url":null,"abstract":"High voltage bushing failures are one of the main causes that affect reliability and availability of high voltage transformers and reactors. Not only reliability and availability are affected, but also failures in these components could produce fires, damages in nearby equipment and injuries to people working in the proximity. It was shown that performing periodic diagnosis or implementing continuous monitoring help to avoid terminal failures. In order to expand knowledge regarding how high voltage bushings age and how the signs of ageing could be detected, the results of the analysis of six high voltage bushings removed preventively from service are presented in this work. These bushings had been operating for between twenty and thirty-three years before being removed. Three of them were pulled out preventively because diagnoses performed over them showed risk of failure. The analysis includes test of dissipation factor (tan δ) and capacitance, tip-up, frequency domain spectroscopy performed during their life in service and lab tests conducted when they were out of services: dissipation factor and capacitance, frequency domain spectroscopy, tip-up, dissipation factor at nominal voltage, partial discharges, DGA and oil analysis performed in laboratory. At the end of the lab test each bushing was disassembled, and a detailed visual inspection was carried out. Oil samples were taken to carry out physical and chemical analysis. Tests results, both field historical and in laboratory, life time in service, visual inspection and oil sample analysis results are presented correlated with the aim of evaluating failure mechanisms that were present, and analyzing which diagnosis tests have shown to be the most suitable to detect their condition.","PeriodicalId":286019,"journal":{"name":"2020 IEEE Electrical Insulation Conference (EIC)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Incipient failures analysis of high voltage bushings\",\"authors\":\"Luciano Enciso, R. Álvarez, José L. Martínez, P. Arce, M. Galliani, Pablo Rodriguez, Emilo Calo\",\"doi\":\"10.1109/eic47619.2020.9158713\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"High voltage bushing failures are one of the main causes that affect reliability and availability of high voltage transformers and reactors. Not only reliability and availability are affected, but also failures in these components could produce fires, damages in nearby equipment and injuries to people working in the proximity. It was shown that performing periodic diagnosis or implementing continuous monitoring help to avoid terminal failures. In order to expand knowledge regarding how high voltage bushings age and how the signs of ageing could be detected, the results of the analysis of six high voltage bushings removed preventively from service are presented in this work. These bushings had been operating for between twenty and thirty-three years before being removed. Three of them were pulled out preventively because diagnoses performed over them showed risk of failure. The analysis includes test of dissipation factor (tan δ) and capacitance, tip-up, frequency domain spectroscopy performed during their life in service and lab tests conducted when they were out of services: dissipation factor and capacitance, frequency domain spectroscopy, tip-up, dissipation factor at nominal voltage, partial discharges, DGA and oil analysis performed in laboratory. At the end of the lab test each bushing was disassembled, and a detailed visual inspection was carried out. Oil samples were taken to carry out physical and chemical analysis. Tests results, both field historical and in laboratory, life time in service, visual inspection and oil sample analysis results are presented correlated with the aim of evaluating failure mechanisms that were present, and analyzing which diagnosis tests have shown to be the most suitable to detect their condition.\",\"PeriodicalId\":286019,\"journal\":{\"name\":\"2020 IEEE Electrical Insulation Conference (EIC)\",\"volume\":\"30 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE Electrical Insulation Conference (EIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/eic47619.2020.9158713\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Electrical Insulation Conference (EIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/eic47619.2020.9158713","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

高压套管失效是影响高压变压器和电抗器可靠性和可用性的主要原因之一。不仅可靠性和可用性受到影响,而且这些部件的故障可能会引起火灾,损坏附近的设备,并对附近工作的人员造成伤害。结果表明,定期诊断或连续监测有助于避免终端故障的发生。为了扩大关于高压套管如何老化以及如何检测老化迹象的知识,本文介绍了对预防性停用的六个高压套管的分析结果。这些套管在被拆除之前已经使用了20到33年。其中三人被预防性地取出,因为对他们进行的诊断显示有失败的风险。分析包括在其使用寿命期间进行的耗散系数(tan δ)和电容、上升、频域光谱测试,以及在其停止使用时进行的实验室测试:耗散系数和电容、频域光谱、上升、标称电压下的耗散系数、局部放电、DGA和实验室进行的油分析。在实验室测试结束时,每个衬套被拆卸,并进行了详细的目视检查。取油样进行物理和化学分析。现场历史和实验室的测试结果、使用寿命、目视检查和油样分析结果与评估存在的故障机制的目的相关联,并分析哪些诊断测试显示最适合检测其状况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Incipient failures analysis of high voltage bushings
High voltage bushing failures are one of the main causes that affect reliability and availability of high voltage transformers and reactors. Not only reliability and availability are affected, but also failures in these components could produce fires, damages in nearby equipment and injuries to people working in the proximity. It was shown that performing periodic diagnosis or implementing continuous monitoring help to avoid terminal failures. In order to expand knowledge regarding how high voltage bushings age and how the signs of ageing could be detected, the results of the analysis of six high voltage bushings removed preventively from service are presented in this work. These bushings had been operating for between twenty and thirty-three years before being removed. Three of them were pulled out preventively because diagnoses performed over them showed risk of failure. The analysis includes test of dissipation factor (tan δ) and capacitance, tip-up, frequency domain spectroscopy performed during their life in service and lab tests conducted when they were out of services: dissipation factor and capacitance, frequency domain spectroscopy, tip-up, dissipation factor at nominal voltage, partial discharges, DGA and oil analysis performed in laboratory. At the end of the lab test each bushing was disassembled, and a detailed visual inspection was carried out. Oil samples were taken to carry out physical and chemical analysis. Tests results, both field historical and in laboratory, life time in service, visual inspection and oil sample analysis results are presented correlated with the aim of evaluating failure mechanisms that were present, and analyzing which diagnosis tests have shown to be the most suitable to detect their condition.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Onsite Testing and Diagnosis of Medium Voltage Resin Impregnated Paper (RIP) Insulated Buses by Using Very Low Frequency High Voltage Analysis and suggestion on the chromatographic detection of inverted oil immersed current transformer Detection of Partial Discharges Occurring in Propulsion Coils of Superconducting Maglev Systems from a Test Bogie Running at High Speed Using a Radio Interferometer System with a Vector-Antenna Life expectancy of high voltage bushings based on incipient failure detections: a practical approach Approaches to the forensic failure investigation of medium voltage polymeric cables
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1