双极电离场的通用有限元分析

M. Abdel-Salam, Z. Al-Hamouz
{"title":"双极电离场的通用有限元分析","authors":"M. Abdel-Salam, Z. Al-Hamouz","doi":"10.1109/IAS.1993.299090","DOIUrl":null,"url":null,"abstract":"A novel iterative method for the analysis of the bipolar ionized field in HVDC (high-voltage direct-current) transmission lines without resort to Deutsch's assumption is described. The finite-element technique is used to solve Poisson's equation where the constancy of the conductor's surface field at the corona inception value is directly implemented in the finite-element formulation. The proposed method has been tested on laboratory and full-scale models. The calculated V-I characteristics agreed well with those calculated and measured before. The dependency of the corona current as well as its monopolar and bipolar components on the conductors' height is discussed. The simplicity in the computer programming in addition to the low number of iterations required to achieve convergence characterize the proposed method of analysis.<<ETX>>","PeriodicalId":345027,"journal":{"name":"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"A universal finite-element analysis of the bipolar ionized field\",\"authors\":\"M. Abdel-Salam, Z. Al-Hamouz\",\"doi\":\"10.1109/IAS.1993.299090\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A novel iterative method for the analysis of the bipolar ionized field in HVDC (high-voltage direct-current) transmission lines without resort to Deutsch's assumption is described. The finite-element technique is used to solve Poisson's equation where the constancy of the conductor's surface field at the corona inception value is directly implemented in the finite-element formulation. The proposed method has been tested on laboratory and full-scale models. The calculated V-I characteristics agreed well with those calculated and measured before. The dependency of the corona current as well as its monopolar and bipolar components on the conductors' height is discussed. The simplicity in the computer programming in addition to the low number of iterations required to achieve convergence characterize the proposed method of analysis.<<ETX>>\",\"PeriodicalId\":345027,\"journal\":{\"name\":\"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.1993.299090\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1993.299090","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本文提出了一种新的分析高压直流输电线路中双极电离场的迭代方法,该方法无需Deutsch假设。采用有限元技术求解泊松方程,其中导体表面场在电晕起始值处的常数直接体现在有限元公式中。该方法已在实验室和全尺寸模型上进行了测试。计算的V-I特性与之前的计算和测量结果吻合较好。讨论了电晕电流及其单极和双极分量与导体高度的关系。计算机编程的简单性以及实现收敛所需的低迭代次数是所提出的分析方法的特点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A universal finite-element analysis of the bipolar ionized field
A novel iterative method for the analysis of the bipolar ionized field in HVDC (high-voltage direct-current) transmission lines without resort to Deutsch's assumption is described. The finite-element technique is used to solve Poisson's equation where the constancy of the conductor's surface field at the corona inception value is directly implemented in the finite-element formulation. The proposed method has been tested on laboratory and full-scale models. The calculated V-I characteristics agreed well with those calculated and measured before. The dependency of the corona current as well as its monopolar and bipolar components on the conductors' height is discussed. The simplicity in the computer programming in addition to the low number of iterations required to achieve convergence characterize the proposed method of analysis.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Maximum torque control of an induction machine in the field weakening region Production of O/W type uniformly sized droplets using a convergent AC electric field The effect of temperature on starting and stabilization of compact fluorescent systems A low cost compact CCD grating spectrometer Surface handling effects of fabricating thin dielectric film HDPE on TSDC analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1