{"title":"超声线带键合过程中结合力的稳定","authors":"I. B. Petuhov","doi":"10.15222/tkea2021.1-2.49","DOIUrl":null,"url":null,"abstract":"To improve the quality of ultrasonic wire and ribbon bonding, the author propose a methodology for stabilizing the bonding force by compensating the rigidity of ultrasonic transducer (UST) mount in the ultrasonic / thermosonic bonding cycle. The author analyze the construction of ultrasonic technological systems and factors affecting the stability of the bonding process. The bonding force is controlled by an electromagnetic unit based on a coil in the field of a constant magnet, the force being directly proportional to the flowing current in the coil. The rigidity of ultrasonic transducer mount was compensated by the data obtained during the preliminary calibration of the change in the mount force over the entire UST overrun range. The calibration in this case is performed with no current flowing through the coil. The force value can be picked up from a digital force sensor. The force values are simultaneously compared with the digitized signal of the deformation sensor. The obtained data is stored in the memory of the wire bonder.\nIn the bonding cycle, after the moment of contact is determined, the drive unit moves the bonding head vertically by the value of a predetermined distance of approximately one diameter of the bonding wire. This causes the movable part of the UST mount to rise and the force to increase. This increase is compensated by the automatic reduction of the current in the electromagnetic coil, which allows maintaining the preset force at the specified level. The bonding force during bonding is compensated in the same way, with the difference that the vector of force compensation changes – the force should increase with an increase in the deformation of the bonding wire. The implementation of the proposed algorithm made it possible to improve the bonding force stabilization to 20% when bonding thick wire, as well as to improve bonding quality. The proposed solution is also applicable in other technological ultrasound bonding systems, including bonding wire with the diameter of <100 microns.","PeriodicalId":231412,"journal":{"name":"Технология и конструирование в электронной аппаратуре","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Stabilization of bonding force during ultrasonic wire and ribbon bonding\",\"authors\":\"I. B. Petuhov\",\"doi\":\"10.15222/tkea2021.1-2.49\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To improve the quality of ultrasonic wire and ribbon bonding, the author propose a methodology for stabilizing the bonding force by compensating the rigidity of ultrasonic transducer (UST) mount in the ultrasonic / thermosonic bonding cycle. The author analyze the construction of ultrasonic technological systems and factors affecting the stability of the bonding process. The bonding force is controlled by an electromagnetic unit based on a coil in the field of a constant magnet, the force being directly proportional to the flowing current in the coil. The rigidity of ultrasonic transducer mount was compensated by the data obtained during the preliminary calibration of the change in the mount force over the entire UST overrun range. The calibration in this case is performed with no current flowing through the coil. The force value can be picked up from a digital force sensor. The force values are simultaneously compared with the digitized signal of the deformation sensor. The obtained data is stored in the memory of the wire bonder.\\nIn the bonding cycle, after the moment of contact is determined, the drive unit moves the bonding head vertically by the value of a predetermined distance of approximately one diameter of the bonding wire. This causes the movable part of the UST mount to rise and the force to increase. This increase is compensated by the automatic reduction of the current in the electromagnetic coil, which allows maintaining the preset force at the specified level. The bonding force during bonding is compensated in the same way, with the difference that the vector of force compensation changes – the force should increase with an increase in the deformation of the bonding wire. The implementation of the proposed algorithm made it possible to improve the bonding force stabilization to 20% when bonding thick wire, as well as to improve bonding quality. The proposed solution is also applicable in other technological ultrasound bonding systems, including bonding wire with the diameter of <100 microns.\",\"PeriodicalId\":231412,\"journal\":{\"name\":\"Технология и конструирование в электронной аппаратуре\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Технология и конструирование в электронной аппаратуре\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15222/tkea2021.1-2.49\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Технология и конструирование в электронной аппаратуре","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15222/tkea2021.1-2.49","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了提高超声丝带键合的质量,提出了一种通过补偿超声换能器(UST)支架刚度来稳定键合力的方法。分析了超声工艺系统的构成及影响粘接过程稳定性的因素。结合力是由一个基于线圈的电磁单元控制的,在恒定的磁场中,该力与线圈中的电流成正比。超声换能器安装的刚度通过在整个UST超限范围内安装力变化的初步校准期间获得的数据进行补偿。在这种情况下,校准是在没有电流流过线圈的情况下进行的。力值可以从数字力传感器中获取。同时将力值与变形传感器的数字化信号进行比较。所获得的数据存储在线键机的存储器中。在键合循环中,在确定接触力矩后,驱动单元将键合头垂直移动约一键合线直径的预定距离值。这导致UST安装的可移动部分上升,力增加。这种增加是由电磁线圈中电流的自动减少来补偿的,这允许在指定的水平上保持预设的力。粘接过程中的粘合力也以同样的方式进行补偿,不同之处在于力补偿的矢量发生了变化——力应该随着粘接丝变形的增加而增加。该算法的实现使粗丝粘接时的粘接力稳定性提高到20%,同时提高了粘接质量。该解决方案也适用于其他工艺超声键合系统,包括直径<100微米的键合线。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Stabilization of bonding force during ultrasonic wire and ribbon bonding
To improve the quality of ultrasonic wire and ribbon bonding, the author propose a methodology for stabilizing the bonding force by compensating the rigidity of ultrasonic transducer (UST) mount in the ultrasonic / thermosonic bonding cycle. The author analyze the construction of ultrasonic technological systems and factors affecting the stability of the bonding process. The bonding force is controlled by an electromagnetic unit based on a coil in the field of a constant magnet, the force being directly proportional to the flowing current in the coil. The rigidity of ultrasonic transducer mount was compensated by the data obtained during the preliminary calibration of the change in the mount force over the entire UST overrun range. The calibration in this case is performed with no current flowing through the coil. The force value can be picked up from a digital force sensor. The force values are simultaneously compared with the digitized signal of the deformation sensor. The obtained data is stored in the memory of the wire bonder. In the bonding cycle, after the moment of contact is determined, the drive unit moves the bonding head vertically by the value of a predetermined distance of approximately one diameter of the bonding wire. This causes the movable part of the UST mount to rise and the force to increase. This increase is compensated by the automatic reduction of the current in the electromagnetic coil, which allows maintaining the preset force at the specified level. The bonding force during bonding is compensated in the same way, with the difference that the vector of force compensation changes – the force should increase with an increase in the deformation of the bonding wire. The implementation of the proposed algorithm made it possible to improve the bonding force stabilization to 20% when bonding thick wire, as well as to improve bonding quality. The proposed solution is also applicable in other technological ultrasound bonding systems, including bonding wire with the diameter of <100 microns.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Changes in the characteristics of silicon photovoltaic cells of solar arrays after current overloads Electrical conductivity of thermosensitive glass-ceramics based on nanosized vanadium dioxide Resistive humidity sensors based on nanocellulose films for biodegradable electronics Synchronization of pulsed and continuous-wave IMPATT oscillators in the millimeter wavelength range. Part 2. Stabilizing microwave parameters of synchronized generators Matrix calculation of correlation characteristics based on spectral methods
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1