PET相互作用深度的蒙特卡罗研究

G. Gulsen, C. Deng, O. Nalcioglu
{"title":"PET相互作用深度的蒙特卡罗研究","authors":"G. Gulsen, C. Deng, O. Nalcioglu","doi":"10.1109/NSSMIC.2003.1352466","DOIUrl":null,"url":null,"abstract":"In this work, we present a Monte Carlo simulation program for the investigation of reconstruction of the entrance point and angle of incidence of /spl gamma/-rays incident on a crystal by using the light output from the adjacent crystals. Initially, the Monte Carlo simulator was used to obtain the light response function (LRF) of each crystal in a detector array with respect to the entrance position and angle of incidence of the incident /spl gamma/-rays. Later, the simulator was used to determine the spatial resolution of a 3-layer detector ring consisting of 200 crystals per layer.","PeriodicalId":186175,"journal":{"name":"2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Monte Carlo study of depth of interaction in PET\",\"authors\":\"G. Gulsen, C. Deng, O. Nalcioglu\",\"doi\":\"10.1109/NSSMIC.2003.1352466\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work, we present a Monte Carlo simulation program for the investigation of reconstruction of the entrance point and angle of incidence of /spl gamma/-rays incident on a crystal by using the light output from the adjacent crystals. Initially, the Monte Carlo simulator was used to obtain the light response function (LRF) of each crystal in a detector array with respect to the entrance position and angle of incidence of the incident /spl gamma/-rays. Later, the simulator was used to determine the spatial resolution of a 3-layer detector ring consisting of 200 crystals per layer.\",\"PeriodicalId\":186175,\"journal\":{\"name\":\"2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515)\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-10-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2003.1352466\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2003.1352466","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在这项工作中,我们提出了一个蒙特卡罗模拟程序,用于研究利用邻近晶体的光输出重建入射到晶体上的/spl伽马/射线的入口点和入射角。首先,利用蒙特卡罗模拟器获得探测器阵列中每个晶体的光响应函数(LRF)与入射/spl伽马/-射线的入射位置和入射角有关。随后,利用该模拟器确定了每层由200个晶体组成的3层探测器环的空间分辨率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Monte Carlo study of depth of interaction in PET
In this work, we present a Monte Carlo simulation program for the investigation of reconstruction of the entrance point and angle of incidence of /spl gamma/-rays incident on a crystal by using the light output from the adjacent crystals. Initially, the Monte Carlo simulator was used to obtain the light response function (LRF) of each crystal in a detector array with respect to the entrance position and angle of incidence of the incident /spl gamma/-rays. Later, the simulator was used to determine the spatial resolution of a 3-layer detector ring consisting of 200 crystals per layer.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Proton irradiation response of CsI(Tl) crystals for the GLAST calorimeter Comparative study of PP0275C hybrid photodetector and XP2020Q photomultiplier in scintillation detection Quality of mass produced lead tungstate crystals SLIM (Secondary emission monitor for Low Interception Monitoring) an innovative non-destructive beam monitor for the extraction lines of a hadrontherapy center Single electron amplification in a "Single-MCP + micromegas + pads" detector
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1