M. Taherzadeh, S. Carriere, F. Betin, M. Joorabian, R. Kianinezhad, G. Capolino
{"title":"六相感应发电机缺相时控制器的在线修改","authors":"M. Taherzadeh, S. Carriere, F. Betin, M. Joorabian, R. Kianinezhad, G. Capolino","doi":"10.1109/ICELMACH.2014.6960278","DOIUrl":null,"url":null,"abstract":"This study presents field oriented control of a squirrel cage six-phase induction generator (SC6PIG) when a phase fault is detected in order to minimize output power oscillations during phase opening. An unbalanced structure of squirrel cage six-phase induction machine (SC6PIM) has been modeled to analyze healthy and faulty conditions of the machine. According to the unbalanced structure of the machine, a suitable controller is defined in phase missing condition to minimize power oscillations. After fault detection by using a dedicated system, the controller used in healthy condition is switched to a new one regarding to the fault situation. For each controller, appropriate initial conditions are chosen to minimize the transient behavior of switching process between healthy and faulty controllers. The whole proposed system has been implemented on an experimental set up including of a six-phase induction generator coupled with a permanent magnet direct current (dc) motor. Experimental results prove the feasibility and show the improvement of power quality when the controller is modified in phase missing conditions. The experimental results are presented for one phase missing and they can also be obtained for two or three phases missing conditions.","PeriodicalId":288960,"journal":{"name":"2014 International Conference on Electrical Machines (ICEM)","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Online controller modifying of a six-phase induction generator in phase opening occurrences\",\"authors\":\"M. Taherzadeh, S. Carriere, F. Betin, M. Joorabian, R. Kianinezhad, G. Capolino\",\"doi\":\"10.1109/ICELMACH.2014.6960278\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study presents field oriented control of a squirrel cage six-phase induction generator (SC6PIG) when a phase fault is detected in order to minimize output power oscillations during phase opening. An unbalanced structure of squirrel cage six-phase induction machine (SC6PIM) has been modeled to analyze healthy and faulty conditions of the machine. According to the unbalanced structure of the machine, a suitable controller is defined in phase missing condition to minimize power oscillations. After fault detection by using a dedicated system, the controller used in healthy condition is switched to a new one regarding to the fault situation. For each controller, appropriate initial conditions are chosen to minimize the transient behavior of switching process between healthy and faulty controllers. The whole proposed system has been implemented on an experimental set up including of a six-phase induction generator coupled with a permanent magnet direct current (dc) motor. Experimental results prove the feasibility and show the improvement of power quality when the controller is modified in phase missing conditions. The experimental results are presented for one phase missing and they can also be obtained for two or three phases missing conditions.\",\"PeriodicalId\":288960,\"journal\":{\"name\":\"2014 International Conference on Electrical Machines (ICEM)\",\"volume\":\"57 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Conference on Electrical Machines (ICEM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICELMACH.2014.6960278\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Electrical Machines (ICEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICELMACH.2014.6960278","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Online controller modifying of a six-phase induction generator in phase opening occurrences
This study presents field oriented control of a squirrel cage six-phase induction generator (SC6PIG) when a phase fault is detected in order to minimize output power oscillations during phase opening. An unbalanced structure of squirrel cage six-phase induction machine (SC6PIM) has been modeled to analyze healthy and faulty conditions of the machine. According to the unbalanced structure of the machine, a suitable controller is defined in phase missing condition to minimize power oscillations. After fault detection by using a dedicated system, the controller used in healthy condition is switched to a new one regarding to the fault situation. For each controller, appropriate initial conditions are chosen to minimize the transient behavior of switching process between healthy and faulty controllers. The whole proposed system has been implemented on an experimental set up including of a six-phase induction generator coupled with a permanent magnet direct current (dc) motor. Experimental results prove the feasibility and show the improvement of power quality when the controller is modified in phase missing conditions. The experimental results are presented for one phase missing and they can also be obtained for two or three phases missing conditions.