{"title":"75kv节电。深水站用海底电缆","authors":"R. Wilbraham","doi":"10.1109/JAIEE.1930.6537005","DOIUrl":null,"url":null,"abstract":"This paper describes the problems attending the laying of eight 75-kv. submarine cables across the Delaware River in the vicinity of Wilmington. To insure against injury, the cables were laid in a backfilled trench the depth of which was determined by experiments. By terminating the cable on platforms just inside the pierhead lines it was possible to use a cable of 4050 ft. (maximum length possible for one of the accepted manufacturers to make) as compared with a river width of 5100 ft. To avoid the excessive healing of that portion of the cable out of water at the cable platforms, the steel armor was replaced by one of nonmagnetic material so designed as to avoid corrosion and electrolysis. The problem of laying the limited lengths of cable in the trench with minimum deviation was satisfactorily met with specially developed methods. The construction work was completed in five months, under winter conditions and with river traffic heavy.","PeriodicalId":260406,"journal":{"name":"Journal of the A.I.E.E.","volume":"161 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1930-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Abridgment of 75-kv. submarine cable for deep water station\",\"authors\":\"R. Wilbraham\",\"doi\":\"10.1109/JAIEE.1930.6537005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes the problems attending the laying of eight 75-kv. submarine cables across the Delaware River in the vicinity of Wilmington. To insure against injury, the cables were laid in a backfilled trench the depth of which was determined by experiments. By terminating the cable on platforms just inside the pierhead lines it was possible to use a cable of 4050 ft. (maximum length possible for one of the accepted manufacturers to make) as compared with a river width of 5100 ft. To avoid the excessive healing of that portion of the cable out of water at the cable platforms, the steel armor was replaced by one of nonmagnetic material so designed as to avoid corrosion and electrolysis. The problem of laying the limited lengths of cable in the trench with minimum deviation was satisfactorily met with specially developed methods. The construction work was completed in five months, under winter conditions and with river traffic heavy.\",\"PeriodicalId\":260406,\"journal\":{\"name\":\"Journal of the A.I.E.E.\",\"volume\":\"161 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1930-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the A.I.E.E.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/JAIEE.1930.6537005\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the A.I.E.E.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/JAIEE.1930.6537005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了8条75kv线路敷设时应注意的问题。海底电缆横跨特拉华河在威尔明顿附近。为了防止损伤,电缆敷设在回填壕中,回填壕的深度由实验确定。通过在码头线内部的平台上终止电缆,可以使用4050英尺的电缆(一个公认的制造商可能制造的最大长度),而不是5100英尺的河宽。为了避免电缆平台上的那部分电缆在水中过度愈合,钢铠被一种非磁性材料取代,这样设计可以避免腐蚀和电解。采用专门开发的方法,较好地解决了在沟槽内以最小偏差敷设有限长度电缆的问题。在冬季条件和河流交通繁忙的情况下,施工工作在五个月内完成。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Abridgment of 75-kv. submarine cable for deep water station
This paper describes the problems attending the laying of eight 75-kv. submarine cables across the Delaware River in the vicinity of Wilmington. To insure against injury, the cables were laid in a backfilled trench the depth of which was determined by experiments. By terminating the cable on platforms just inside the pierhead lines it was possible to use a cable of 4050 ft. (maximum length possible for one of the accepted manufacturers to make) as compared with a river width of 5100 ft. To avoid the excessive healing of that portion of the cable out of water at the cable platforms, the steel armor was replaced by one of nonmagnetic material so designed as to avoid corrosion and electrolysis. The problem of laying the limited lengths of cable in the trench with minimum deviation was satisfactorily met with specially developed methods. The construction work was completed in five months, under winter conditions and with river traffic heavy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Looking backward Power transmission A quantitative study of regeneration by inductive feed back National electrical manufacturers association A portable radio direction finder
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1